FDA Adverse Event Malfunction Summary report: N

PDSII CLR 18IN 4-0 S/A P-3 PRM MP

MDR report key: 19041726 · Received April 4, 2024

Report

Report Number
2210968-2024-03850
Event Type
Malfunction
Date Received
April 4, 2024
Report Date
September 25, 2024
Manufacturer
ETHICON INC.
Product Code
NEW
UDI-DI
10705031061170
PMA / PMN Number
N18331
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

(B)(4) THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON INC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. THE FOLLOWING INFORMATION WAS REQUESTED, BUT UNAVAILABLE: PLEASE PROVIDE LOT NUMBER INVESTIGATION SUMMARY THE PRODUCT WAS RETURNED TO ETHICON FOR EVALUATION. VISUAL INSPECTION EVALUATION WAS CONDUCTED ON THE RETURNED DEVICE. VISUAL ANALYSIS OF THE RETURNED SAMPLE DETERMINED THAT ONE NEEDLE AND ONE SUTURE OUTSIDE ITS PACKAGING THAT PERTAINS TO PRODUCT CODE Z494G WERE RETURNED TO ETHICON FOR ANALYSIS. IN ORDER TO EVALUATE THE CONDITIONS OF THE RETURNED SAMPLE, IT WAS OBSERVED THE NEEDLE WAS BROKEN AT THE SWAGE AREA AND A PART OF THE NEEDLE WAS NOTED TO BE ATTACHED ON THE SUTURE. THE SAMPLES WILL BE SHIPPED TO HSA FOR FURTHER ANALYSIS DUE TO THE NEEDLE BREAKAGE. MARKS THAT APPEAR TO BE BY USE OF THE SURGICAL INSTRUMENT. WERE OBSERVED. AS PART OF OUR QUALITY PROCESS, THE MANUFACTURING RECORDS OF THIS LOT-SERIAL NUMBER WERE REVIEWED, AND THE MANUFACTURING STANDARDS WERE MET PRIOR TO THE RELEASE OF THIS BATCH. NO CONCLUSION COULD BE REACHED DUE TO THE SAMPLE NEEDS ADDITIONAL EVALUATION BY HSA. AS PART OF THE ETHICON QUALITY PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS. ADDITIONAL COMPLAINT INFORMATION MONITORING FOR POTENTIAL SAFETY SIGNALS IS CONDUCTED THROUGH COMPLAINT TRENDING AS PART OF POST-MARKET SURVEILLANCE.

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). DATE SENT TO THE FDA: 5/20/2024. H3 INVESTIGATIONAL SUMMARY: THE PRODUCT RECEIVED FOR ANALYSIS WAS IDENTIFIED AS PRODUCT CODE Z494G. VISUAL INSPECTION AND METALLURGICAL ANALYSIS WERE PERFORMED ON THE RETURNED PRODUCT. A FRACTURE WAS OBSERVED AT THE SUTURE ATTACHMENT OF THE NEEDLE. ONE SIDE OF THE NEEDLE WAS RECEIVED, THE MATING FRACTURE SURFACE WAS NOT PROVIDED FOR THIS EVALUATION. THE NEEDLE WAS NOTED WITH MARKS THAT APPEARS TO BE BY SURGICAL INSTRUMENT. A SCANNING ELECTRON MICROSCOPE WAS USED TO EXAMINE THE FRACTURE SURFACE AND SURROUNDING AREA OF THE NEEDLE. THE FRACTURE SURFACES WERE EXAMINED IN MULTIPLE LOCATIONS TO DETERMINE THE FRACTURE MODE. THE EVALUATION OF THE SAMPLE REVEALED THE FRACTURE CONTAINED A ¿WOODY¿ STRUCTURE NEAR THE SUTURE ATTACHMENT. THIS IS CONSISTENT WITH A FAILURE IN THE FORMING DIRECTION OF THE WIRE. AN AREA OF MICROVOID COALESCENCE, WHICH IS EVIDENCE OF A DUCTILE FRACTURE MODE WAS ALSO NOTED. THIS SHOWED SOME EVIDENCE OF A DUCTILE FRACTURE. THE EVIDENCE OF THIS EXAMINATION INDICATES THAT THE BREAKAGE OCCURRED AT THE ATTACHMENT AREA OF THE NEEDLE DURING USE DUE TO TENSILE OVERLOAD. THERE IS NO EVIDENCE OF ANY MATERIAL FLAW OR DEFECT THAT WOULD CAUSE PREMATURE FAILURE. ADDITIONAL COMPLAINT INFORMATION MONITORING FOR POTENTIAL SAFETY SIGNALS IS CONDUCTED THROUGH COMPLAINT TRENDING AS PART OF POST-MARKET SURVEILLANCE. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON INC OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). DATE SENT TO THE FDA: 9/25/2024. D4: UDI: AS THE LOT NUMBER FOR THE DEVICE INVOLVED IN THE EVENT WAS NOT PROVIDED, THE FULL UDI IS CURRENTLY NOT AVAILABLE. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON INC OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 0

IT WAS REPORTED THAT PATIENT UNDERWENT AN UNKNOWN PROCEDURE ON AN UNKNOWN DATE, AND SUTURE WAS USED. DURING THE SURGERY, AFTER OPENING THE PACKAGE AND BEFORE USE, IT WAS FOUND THAT THE SHAPE OF THE NEEDLE TIP WAS ABNORMAL. ANOTHER PRODUCT WAS USED. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
66318 PDSII CLR 18IN 4-0 S/A P-3 PRM MP SUTURE, SURGICAL, ABSORBABLE NEW ETHICON INC. 10705031061170

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown