LAMINAR
Report
- Report Number
- 3012236936-2024-00868
- Event Type
- Malfunction
- Date Received
- March 25, 2024
- Date of Event
- January 2, 2024
- Report Date
- March 25, 2024
- Manufacturer
- JOHNSON & JOHNSON SURGICAL VISION, INC.
- Product Code
- HQC
- UDI-DI
- 05050474573376
- PMA / PMN Number
- K121721
- Removal / Correction Number
- SEE H10
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- 003
Narratives
ADDITIONAL NARRATIVE: NOTE: THIS MDR REPORT IS BEING SUBMITTED AS PART OF A REMEDIAL ACTION TO PREVENT SERIOUS INJURY. SECTION A2, A3, A4, A5: NOT APPLICABLE AS THERE WAS NO PATIENT INVOLVEMENT. SECTION D6A: IF IMPLANTED, GIVE DATE: NOT APPLICABLE AS THIS IS NOT AN IMPLANTABLE DEVICE. SECTION D6B: IF EXPLANTED, GIVE DATE: NOT APPLICABLE AS THIS IS NOT AN IMPLANTABLE DEVICE. SECTION H3-OTHER (81): THE DEVICE WAS NOT RETURNED FOR EVALUATION; THEREFORE, A FAILURE ANALYSIS OF THE COMPLAINT DEVICE CANNOT BE COMPLETED. A REVIEW OF THE DEVICE HISTORY RECORD, COMPLAINT TRENDING, AND RISK DOCUMENTATION FOR THIS DEVICE WILL BE PERFORMED. UPON COMPLETION OF THE REVIEW, IF THERE IS ANY FURTHER RELEVANT INFORMATION A SUPPLEMENTAL MEDWATCH WILL BE FILED. SECTION H9: THE JJSV REFERENCE NUMBER IS (B)(4). THE NUMBER WAS OMITTED DUE TO THE COMPLAINT HANDLING SYSTEM CHARACTER LIMITATION. JOHNSON & JOHNSON SURGICAL VISION (JJSV) HAS INITIATED A FIELD ACTION RELATED TO SELECT LOTS OF LAMINAR® FLOW IRRIGATION SLEEVE AND TEST CHAMBER ¿ 21 GAUGE (PART NUMBER: OPOHF21L) DUE TO A MANUFACTURING ISSUE WHICH COULD LEAD TO SUBPAR PERFORMANCE DURING CATARACT SURGERY. WHILE NOT ALL THE IRRIGATION SLEEVES IN THE RECALLED LOTS ARE AFFECTED, THIS NON-CONFORMANCE COULD LEAD TO INSUFFICIENT FLOW OF BALANCED SALINE SOLUTION (BSS), WHICH MAY RESULT IN AN UNSTABLE ANTERIOR CHAMBER. THIS DEFECT COULD RESULT IN A CAPSULE TEAR, IRIS TRAUMA, OR CORNEAL EDEMA, OR IN RARE INSTANCES A CORNEAL INCISION BURN. COMPLAINTS WILL CONTINUE TO BE MONITORED AND INVESTIGATED. INVESTIGATION IS ONGOING AND CORRECTIVE ACTION WILL BE IMPLEMENTED AS APPROPRIATE. ALL PERTINENT INFORMATION AVAILABLE TO JOHNSON & JOHNSON SURGICAL VISION, INC. HAS BEEN SUBMITTED.
IT WAS REPORTED THAT ACCOUNT RECEIVED A BOX OF OPOHF21L WITH ONLY 1 IRRIGATION HOLE. THERE IS NO PATIENT ADVERSE EVENT TO REPORT. THERE WAS NO MEDICAL OR SURGICAL INTERVENTION REQUIRED. NO FURTHER INFORMATION IS AVAILABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 408928 | LAMINAR | UNIT, PHACOFRAGMENTATION | HQC | JOHNSON & JOHNSON SURGICAL VISION, INC. | OPOHF21L | 60479361 | 05050474573376 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |