FDA Adverse Event Malfunction Summary report: N

SFXSPI MCL+ UNI UD 18IN 3-0 SA PS PMP

MDR report key: 18963566 · Received March 22, 2024

Report

Report Number
2210968-2024-03362
Event Type
Malfunction
Date Received
March 22, 2024
Date of Event
January 1, 2024
Report Date
April 12, 2024
Manufacturer
ETHICON INC.
Product Code
GAM
UDI-DI
10705031236660
PMA / PMN Number
N12159
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT (B)(4). H6 COMPONENT CODE: G07002 - DEVICE NOT RETURNED THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803, PART 4 SUBPART B. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. ATTEMPTS HAVE BEEN MADE TO RETRIEVE THE DEVICE. TO DATE THE DEVICE HAS NOT BEEN RETURNED. IF THE DEVICE OR FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. *WERE THERE ANY PATIENT CONSEQUENCES DURING ANY OF THESE CASES? * PLEASE PROVIDE THE SOURCE OR NAME AND TITLE OF THE EXTERNAL PERSON PROVIDING ANSWERS TO FOLLOW-UP (EXTERNAL PERSON SUBMITTING ANSWERS TO SALES REP) * PLEASE PERFORM AND DOCUMENT THE FOLLOW-UP ATTEMPT FOR PRODUCT RETURN. PLEASE DOCUMENT THE SHIPMENT TRACKING NUMBER IN THE NOTES OR RMAO SECTIONS. EVENTS REPORTED VIA: MWR-15032024-0001594558, MWR-15032024-0001594559.

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4) DATE SENT TO THE FDA: 4/12/2024. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803, PART 4 SUBPART B. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). DATE SENT TO THE FDA: 5/9/2024 THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803, PART 4 SUBPART B. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. H6 COMPONENT CODE: G07002 NO DEVICE PROBLEM FOUND ADDITIONAL INFORMATION: D9, H3, H6 A MANUFACTURING RECORD EVALUATION WAS PERFORMED FOR THE FINISHED DEVICE LOT, AND NO NON-CONFORMANCES WERE IDENTIFIED. H3 INVESTIGATIONAL SUMMARY: THE PRODUCT WAS RETURNED TO ETHICON FOR EVALUATION. THE RETURNED SAMPLE DETERMINED THAT IT WAS RECEIVED ONE NEEDLE-SUTURE PIECE OUTSIDE ITS PACKAGING THAT PERTAINS TO PRODUCT CODE SXMP1B11114. UPON VISUAL INSPECTION, THE RETURNED SAMPLE, THE SWAGE, AND THE ATTACHMENT AREA WERE NOTED TO BE AS EXPECTED. THE NEEDLE WAS NOTED WITH THE SUTURE TO BE STILL ATTACHED TO THE BARREL HOLES. OVERALL, NO NEEDLE PULL-OFF WAS OBSERVED. BESIDES, A NEEDLE PULL STRENGTH TEST WAS NOT POSSIBLE TO PERFORM ACCORDING TO SUTURE LENGTH. THE EXTREME OF THE SUTURE PIECE WAS OBSERVED TO BE CUT POSSIBLY CAUSED BY A SURGICAL INSTRUMENT. AS PART OF ETHICON QUALITY PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS. ADDITIONAL COMPLAINT INFORMATION MONITORING FOR POTENTIAL SAFETY SIGNALS IS CONDUCTED THROUGH COMPLAINT TRENDING AS PART OF POST-MARKET SURVEILLANCE. ADDITIONAL H3 INVESTIGATIONAL SUMMARY: THE PRODUCT WAS RETURNED TO ETHICON FOR EVALUATION. VISUAL ANALYSIS OF THE RETURNED SAMPLE DETERMINED THAT FORTY-EIGHT PACKETS THAT PERTAINS TO PRODUCT CODE SXMP1B111 WERE RECEIVED FOR EVALUATION. UPON INITIAL INSPECTION, OF THE SAMPLES, NO EXTERNAL DAMAGES WERE OBSERVED ON THE PACKETS. AS PER THE SAMPLING PLAN, A VISUAL INSPECTION WAS PERFORMED ON THIRTEEN SAMPLES, THE PACKETS WERE OPENED, AND THE SWAGE AND ATTACHMENT AREA WERE NOTED TO BE AS EXPECTED. THE SUTURES WERE DISPENSED WITHOUT PROBLEMS AND EXAMINED ALONG THE STRAND TO DETECT ANY ISSUE RELATED NO DEFECTS WERE OBSERVED DURING EVALUATION. A FUNCTIONAL TEST WAS PERFORMED USING INSTRON EQUIPMENT AND THE PULL FORCE RESULT WAS ABOVE THE MINIMUM REQUIREMENTS. THE EVENT DESCRIBED COULD NOT BE CONFIRMED AS THE DEVICE PERFORMED WITHOUT ANY DEFECT NOTED. AS PART OF THE ETHICON QUALITY PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS. ADDITIONAL COMPLAINT INFORMATION MONITORING FOR POTENTIAL SAFETY SIGNALS IS CONDUCTED THROUGH COMPLAINT TRENDING AS PART OF POST-MARKET SURVEILLANCE. PRODUCT COMPLAINT # (B)(4) DATE SENT TO THE FDA: 5/9/2024 CORRECTED INFORMATION: D1 THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803, PART 4 SUBPART B. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). DATE SENT TO THE FDA: 4/12/2024. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803, PART 4 SUBPART B. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. A REVIEW OF THE BATCH MANUFACTURING RECORDS WAS CONDUCTED, AND NO RELATED NON-CONFORMANCES WERE IDENTIFIED. ADDITIONAL INFORMATION WAS REQUESTED, THE FOLLOWING WAS OBTAINED: WERE THERE ANY PATIENT CONSEQUENCES DURING ANY OF THESE CASES? NO. PLEASE PROVIDE THE SOURCE OR NAME AND TITLE OF THE EXTERNAL PERSON PROVIDING ANSWERS TO FOLLOW-UP (EXTERNAL PERSON SUBMITTING ANSWERS TO SALES REP) (B)(6). (HEAD OR NURSE). PLEASE PERFORM AND DOCUMENT THE FOLLOW-UP ATTEMPT FOR PRODUCT RETURN. PLEASE DOCUMENT THE SHIPMENT TRACKING NUMBER IN THE NOTES OR RMAO SECTIONS. I DO NOT HAVE ACCESS TO THE TRACKING NUMBER AS IT WAS SENT TO ANOTHER EMAIL OR PERSON IN THE COMPANY. PRODUCTS CONCERNING BOTH PCS WERE PICKED UP BY FEDEX ON MONDAY MARCH 18TH.

Description of Event or Problem · 0

IT WAS REPORTED THAT A PATIENT UNDERWENT AN ORTHOPEDIC PROCEDURE IN 2024 AND BARBED SUTURE WAS USED. DURING THE PROCEDURE, THE SUTURE WOULD BREAK FROM THE NEEDLE OR WHEN THEY WOULD DO FINISH THEIR LAST PASS, SAME THING WOULD HAPPEN. THIS HAPPENED SEVERAL TIMES RECENTLY BUT WE WERE ABLE TO RECOVER 2 FAULTY SUTURES. CUSTOMER WOULD LIKE TO RETURN ALL BOXES THAT WERE FROM THE SAME LOT AS A PRECAUTION. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
877797 SFXSPI MCL+ UNI UD 18IN 3-0 SA PS PMP SUTURE, SURGICAL, ABSORBABLE, POLYGLCOLIC ACID GAM ETHICON INC. TJBEDA 10705031236660

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown