ZENITH AAA ENDOVASCULAR GRAFT AAA ANCILLARY COMPONENT CONVERTER
Report
- Report Number
- 1820334-2010-00551
- Event Type
- Death
- Date Received
- November 5, 2010
- Date of Event
- August 25, 2010
- Report Date
- October 8, 2010
- Manufacturer
- COOK INC
- Product Code
- MIH
- PMA / PMN Number
- P020018
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
Narratives
EVENT EVAL: STILL UNDER INVESTIGATION.
PRIOR TO EVAR, AN (B)(6) FEMALE PT REC'D THE BYPASS SURGERY OF THE LEFT COMMON ILIAC ARTERY AND THE FEMORAL ARTERIES AND THE RIGHT EXTERNAL ILIAC ARTERY EMBOLIZATION WERE PERFORMED. ON (B)(6) 2010, SHE UNDERWENT AAA REPAIR. THE PROXIMAL NECK ANGLE RELATIVE TO THE LONG AXIS OF THE ANEURYSM WAS MORE THAN 100 DEGREES, AND BOTH ACCESS ROUTES WERE NOT SUITABLE. THE PROCEDURE WAS PERFORMED UNDER GENERAL ANESTHESIA, AND THE RIGHT INTERNAL ILIAC ARTERY WAS COIL EMBOLIZED FIRST. THE PROCEDURE CONSISTED OF PLACEMENT OF A ZENITH FLEX MAIN BODY GRAFT, A ZENITH FLEX ILIAC LEG GRAFT, A ZENITH AAA ENDOVASCULAR GRAFT AAA ANCILLARY COMPONENT CONVERTER AND A ZENITH AAA ENDOVASCULAR GRAFT AAA ANCILLARY COMPONENT MAIN BODY EXTENSION. THE DELIVERY SYSTEMS WERE INSERTED VIA THE ARTIFICIAL VESSEL ANASTOMOSED TO THE END OF THE LEFT COMMON ILIAC ARTERY. DURING PLACEMENT OF THE CONVERTER AFTER PLACEMENT OF THE MAINBODY, APPROX 500CC OF BLOOD LEAKED FROM THE VALVE. THE ILIAC LEG GRAFT WAS PLACED. THEN THE MAIN BODY EXTENSION WAS PLACED BECAUSE A PROXIMAL TYPE I ENDOLEAK WAS CONFIRMED; APPROX 500-1000CC OF BLOOD LEAKED FROM THE VALVE; (1820334-2010-00550) AUTOLOGOUS BLOOD COLLECTION AND TRANSFUSION WAS PERFORMED BUT THE BLOOD PRESSURE DECREASED TO THE HALF OF NORMAL REVEL AND DID NOT INCREASE. INSERTION OF SHEATH OR CATHETER INTO THE VALVES WAS NOT PERFORMED. IT TOOK FOR ABOUT 7 DAYS TO INCREASE THE BLOOD PRESSURE TO AROUND 100 BY TOTAL OF 10KG OF TRANSFUSION AND ADRENALINE ADMINISTRATION. THE PT HAD BEEN INTUBATED FOR ARTIFICIAL RESPIRATION, AND ADMINISTERED A LARGE QUANTITY OF CARDIOTONIC BECAUSE SHE WAS IN SHOCK. SHE ALSO HAD BEEN UNDER MAINTENANCE DIALYSIS DUE TO DECLINE IN RENAL FUNCTION. THE INTUBATION COULD NOT BE REMOVED DUE TO FATIGUE OF THE RESPIRATORY MUSCLES DUE TO THOSE PROCEDURES AND TREATMENTS, AND IT CAUSED VENTILATOR-ASSOCIATED PNEUMONIA. THEN SHE DEVELOPED DISSEMINATED INTRAVASCULAR CLOTTING. ON (B)(6) 2010, THE PT DECEASED OF VENTILATOR-ASSOCIATED PNEUMONIA.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | ZENITH AAA ENDOVASCULAR GRAFT AAA ANCILLARY COMPONENT CONVERTER | MIH SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT | MIH | COOK INC | NA | F2273888 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 83 YR | Death |