FDA Adverse Event Death Summary report: N

ZENITH AAA ENDOVASCULAR GRAFT AAA ANCILLARY COMPONENT MAIN BODY EXTENSION

MDR report key: 1894403 · Received November 9, 2010

Report

Report Number
1820334-2010-00550
Event Type
Death
Date Received
November 9, 2010
Date of Event
August 25, 2010
Report Date
October 8, 2010
Manufacturer
COOK, INC.
Product Code
MIH
PMA / PMN Number
P020018
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

EVENT EVALUATION: STILL UNDER INVESTIGATION.

Description of Event or Problem · 1

PRIOR TO EVAR, (B)(6) FEMALE PATIENT RECEIVED THE BYPASS SURGERY OF THE LEFT COMMON ILIAC ARTERY AND THE FEMORAL ARTERIES AND THE RIGHT EXTERNAL ILIAC ARTERY EMBOLIZATION WERE PERFORMED. ON (B)(6) 2010, SHE UNDERWENT AAA REPAIR. THE PROXIMAL NECK ANGLE RELATIVE TO THE LONG AXIS OF THE ANEURYSM WAS MORE THAN 100 DEGREES, AND BOTH ACCESS ROUTES WERE NOT SUITABLE. THE PROCEDURE WAS PERFORMED UNDER GENERAL ANESTHESIA, AND THE RIGHT INTERNAL ILIAC ARTERY WAS COIL EMBOLIZED FIRST. THE PROCEDURE CONSISTED OF PLACEMENT OF A ZENITH FLEX MAIN BODY GRAFT, A ZENITH FLEX ILIAC LEG GRAFT, A ZENITH AAA ENDOVASCULAR GRAFT AAA ANCILLARY COMPONENT CONVERTER AND A ZENITH AAA ENDOVASCULAR GRAFT AAA ANCILLARY COMPONENT MAIN BODY EXTENSION. THE DELIVERY SYSTEMS WERE INSERTED VIA THE ARTIFICIAL VESSEL ANASTOMOSED TO THE END OF THE LEFT COMMON ILIAC ARTERY. DURING PLACEMENT OF THE CONVERTER AFTER PLACEMENT OF THE MAINBODY, APPROX 500CC OF BLOOD LEAKED FROM THE VALVE. (1820334-2010-00551). THE ILIAC LEG GRAFT WAS PLACED. THEN THE MAIN BODY EXTENSION WAS PLACED BECAUSE A PROXIMAL TYPE I ENDOLEAK WAS CONFIRMED; APPROX 500-1000CC OF BLOOD LEAKED FROM THE VALVE. AUTOLOGOUS BLOOD COLLECTION AND TRANSFUSION WAS PERFORMED BUT THE BLOOD PRESSURE DECREASED TO THE HALF OF NORMAL REVEL AND DID NOT INCREASE. INSERTION OF SHEATH OR CATHETER INTO THE VALVES WAS NOT PERFORMED. IT TOOK ABOUT 7 DAYS TO INCREASE THE BLOOD PRESSURE TO AROUND 100 BY TOTAL OF 10KG OF TRANSFUSION AND ADRENALINE ADMINISTRATION. THE PATIENT HAD BEEN INTUBATED FOR ARTIFICIAL RESPIRATION, AND ADMINISTERED A LARGE QUANTITY OF CARDIOTONIC BECAUSE SHE WAS IN SHOCK. SHE ALSO HAD BEEN UNDER MAINTENANCE DIALYSIS DUE TO DECLINE IN RENAL FUNCTION. THE INTUBATION COULD NOT BE REMOVED DUE TO FATIGUE OF THE RESPIRATORY MUSCLES DUE TO THOSE PROCEDURES AND TREATMENTS, AND IT CAUSED VENTILATOR-ASSOCIATED PNEUMONIA. THEN SHE DEVELOPED DISSEMINATED INTRAVASCULAR CLOTTING. ON (B)(6) 2010, THE PATIENT DECEASED OF VENTILATOR-ASSOCIATED PNEUMONIA.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 ZENITH AAA ENDOVASCULAR GRAFT AAA ANCILLARY COMPONENT MAIN BODY EXTENSION MIH SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT MIH COOK, INC. NA F2438356

Patients

Seq Age Sex Outcome Treatment
1 83 YR Death