FDA Adverse Event Injury Summary report: N

ARCTIC FRONT ADVANCE PRO¿ CARDIAC CRYOABLATION CATHETER

MDR report key: 18859968 · Received March 7, 2024

Report

Report Number
3002648230-2024-00074
Event Type
Injury
Date Received
March 7, 2024
Date of Event
January 1, 2023
Report Date
March 7, 2024
Manufacturer
MEDTRONIC CRYOCATH LP
Product Code
OAE
PMA / PMN Number
P100010
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NL
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THIS INFORMATION IS BASED ENTIRELY ON JOURNAL LITERATURE. MEDTRONIC WAS MADE AWARE OF THIS EVENT THROUGH A SEARCH OF LITERATURE PUBLICATIONS. THIS EVENT OCCURRED OUTSIDE THE US. PATIENT INFORMATION IS LIMITED DUE TO CONFIDENTIALITY CONCERNS. OF NOTE, MULTIPLE PATIENTS AND MULTIPLE MANUFACTURERS WERE NOTED IN THE ARTICLE; HOWEVER, A ONE-TO-ONE CORRELATION COULD NOT BE MADE WITH UNIQUE PRODUCT SERIAL/LOT NUMBERS. THE BASELINE GENDER/AGE CHARACTERISTICS IS MALE/60 YEARS OLD. WITHOUT A LOT NUMBER OR DEVICE SERIAL NUMBER, THE MANUFACTURING DATE CANNOT BE DETERMINED. SINCE NO DEVICE ID WAS PROVIDED, IT IS UNKNOWN IF THIS EVENT HAS BEEN PREVIOUSLY REPORTED. REFERENCED ARTICLE: ROBOTIC MAGNETIC NAVIGATION-GUIDED CATHETER ABLATION ESTABLISHES HIGHLY EFFECTIVE PULMONARY VEIN ISOLATION IN PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION WHEN COMPARED TO CONVENTIONAL ABLATION TECHNIQUES. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. 2023; 34:2472¿2483. DOI: 10.1111/JCE.16081 MEDTRONIC IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ¿DEFECTS¿ OR HAS ¿MALFUNCTIONED¿. THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REGULATORY REPORTING. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE THEM BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 0

LITERATURE WAS REVIEWED REGARDING VARIOUS TECHNIQUES FOR CATHETER ABLATION WHICH INCLUDED MANUAL GUIDED CRYOBALLOON ABLATION. THE AUTHORS DESCRIBED TWO MAJOR COMPLICATIONS IN THE CRYOBALLOON ABLATION GROUP. THERE WAS ONE PATIENT WHO EXPERIENCED CARDIAC TAMPONADE DUE TO LEFT ATRIUM (LA) WALL PERFORATION BY THE CATHETER TIP. AN EMERGENT PERICARDIOCENTESIS AND THORACIC SURGERY WERE PERFORMED, AND THE PATIENT RECOVERED. THERE WAS ANOTHER PATIENT WHO HAD PERMANENT PARALYSIS OF THE RIGHT HEMIDIAPHRAGM. THE STATUS OF THE CATHETERS IS UNKNOWN. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2379003 ARCTIC FRONT ADVANCE PRO¿ CARDIAC CRYOABLATION CATHETER CATHETER, PERCUTANEOUS, CARDIAC ABLATION, FOR TREATMENT OF ATRIAL FIBRILLATION OAE MEDTRONIC CRYOCATH LP AFAPRO28

Patients

Seq Age Sex Outcome Treatment
1 60 YR Male Required Intervention| L