FDA Adverse Event Death Summary report: N

FLEXNAV DELIVERY SYSTEM

MDR report key: 18841390 · Received March 5, 2024

Report

Report Number
2135147-2024-01005
Event Type
Death
Date Received
March 5, 2024
Date of Event
January 29, 2024
Report Date
March 13, 2024
Manufacturer
ABBOTT MEDICAL
Product Code
NPT
UDI-DI
05415067031372
PMA / PMN Number
P190023
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
UK
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

INVESTIGATION IS NOT YET COMPLETE. A FOLLOW-UP REPORT WILL BE SUBMITTED WITH ALL ADDITIONAL RELEVANT INFORMATION.

Additional Manufacturer Narrative · 0

AN EVENT OF DIFFICULT ADVANCEMENT THROUGH PATIENT ANATOMY AND DEATH WAS REPORTED. THE DEVICE HISTORY RECORD WAS REVIEWED TO ENSURE THAT EACH MANUFACTURING AND INSPECTION OPERATION WAS PERFORMED, AND THE PRODUCT MET ALL SPECIFICATIONS. THE COMPLAINT DATABASE WAS REVIEWED, AND NO RELATED INCIDENTS WERE FOUND FOR THE LOT. INFORMATION FROM THE FIELD INDICATED THAT THERE WAS DIFFICULTY DEPLOYING AND RETRACTING THE VALVE DURING THE PROCEDURE DUE TO THE PATIENT'S HORIZONTAL AORTIC ANGLE. POST-PROCEDURE, THE PATIENT WAS DIAGNOSED WITH A MULTI TERRITORY STROKE AS WELL AS AORTIC DISSECTION IN THE ASCENDING AORTA. IT WAS THOUGHT THIS DISSECTION WAS DUE TO SNARING THE MIGRATED VALVE ALONG WITH DIFFICULTY CROSSING THE HORIZONTAL AORTA WITH BOTH FLEXNAV DELIVERY SYSTEMS. IT WAS THOUGHT THE STROKE WAS RELATED TO BOTH VALVES CAUSING DEBRIS EMBOLIZATION, MULTIPLE BALLOON VALVULOPLASTY'S, AND DIFFICULTY CROSSING THE AORTIC VALVE DUE TO HORIZONTAL ANGLE WITH BOTH FLEXNAV DELIVERY SYSTEMS. THE PATIENT DIED THREE DAYS POST-PROCEDURE. THE CAUSE OF DEATH WAS DUE TO THE AORTIC DISSECTION AND STROKE. THE EVENT WAS FURTHER REVIEWED BY AN ABBOTT SENIOR DIRECTOR OF MEDICAL AFFAIRS. BASED ON AVAILABLE INFORMATION, THE REPORTED EVENT APPEARS TO BE RELATED TO A COMBINATION OF PROCEDURAL CONDITIONS (MULTIPLE BALLOON VALVULOPLASTIES, DECISION TO SNARE OTHER VALVE, ETC.) AND PATIENT CONDITION (SEVERE CALCIFICATION, HORIZONTAL AORTIC VALVE ANGLE). THERE IS NO INDICATION OF A PRODUCT QUALITY ISSUE WITH REGARDS TO MANUFACTURE, DESIGN, OR LABELING.

Description of Event or Problem · 0

IT WAS REPORTED THAT ON (B)(6) 2024, A 27MM NAVITOR VALVE WAS CHOSEN FOR IMPLANTATION INTO A BICUSPID AORTIC VALVE ANATOMY TYPE 1 UTILIZING A FLEXNAV DELIVERY SYSTEM. THE PATIENT PRESENTED WITH SEVERE CALICUM SCORE OF 6251, SEVERE AORTIC STENOSIS, AND HORIZONTAL AORTA. THE VALVE WAS PRE-DILATED WITH A 18MM BALLOON ((BALLOON ANNULAR VALVULOPLASTY (BAV)). A GUIDEWIRE AND A BUDDY WIRE WAS NEEDED TO TRAVERSE THE DIFFICULT HORIZONTAL AORTA. AT DEPLOYMENT, THE NAVITOR WAS PLACED AT 5MM IN LEFT CORONARY CUSP (LCC), 4MM IN NON-CORONARY CUSP (NCC), AND 5MM IN RIGHT CORONARY CUSP (RCC).AFTER FULL RELEASE, THE 27MM NAVITOR WAS AT 5MM IN LCC, 4 MM IN NCC AND 6MM IN RCC. NO TENSION IN DELIVERY SYSTEM DURING DEPLOYMENT. THE VALVE LOOKED CONSTRAINED DUE TO THE SEVERE CALCIFICATION AND MODERATE PERIVALVULAR LEAK (PVL) WAS PRESENT. POST-BAV DILATATION WAS PERFORMED WITH A 20MM BALLOON. ONCE THE BALLOON WAS REMOVED, THE NAVITOR MIGRATED SUPRA ANNULAR. THERE WAS NO BLOCKING OF CORONARY ARTERIES AND NO CLINICAL SIGNS OR SYMPTOMS DUE TO THE MIGRATION. THE VALVE WAS SNARED AND PLACED 5 CM ABOVE THE AORTIC ANNULUS. A REPLACEMENT 25MM NAVITOR (SERIAL:(B)(6)) WAS THEN IMPLANTED. DUE TO VALVE UNDER EXPANSION, POST-BAV DILATATION WAS PERFORMED WITH 20MM BALLOON SEVEN TIMES. GRADIENT OF 13MMHG. THE PROCEDURE ENDED WITH MILD PVL PRESENT ON ECHOCARDIOGRAM. THERE WAS REPORTEDLY A DELAY THAT RESULTED IN NO PATIENT EFFECTS. POST PROCEDURE, AFTER REMOVAL FROM GENERAL ANESTHESIA, THE PATIENT WAS CONFUSED AND HAVING TROUBLE WAKING UP. SUFFERED A . COMPUTERIZED TOMOGRAPHY SCAN WAS TAKEN WHICH ALSO REVEALED MULTI TERRITORY STROKE AS WELL AS AORTIC DISSECTION IN THE ASCENDING AORTA. IT WAS THOUGHT THIS DISSECTION WAS DUE TO SNARING THE MIGRATED VALVE ALONG WITH DIFFICULTY CROSSING THE HORIZONTAL AORTA WITH BOTH FLEXNAV DELIVERY SYSTEMS. IT WAS THOUGHT THE STROKE WAS RELATED TO BOTH VALVES CAUSING DEBRIS EMBOLIZATION, MULTIPLE BALLOON VALVULOPLASTY'S, AND DIFFICULTY CROSSING AORTIC VALVE DUE TO HORIZONTAL ANGLE WITH BOTH FLEXNAV DELIVERY SYSTEMS. THE PATIENT WAS NOT A SURGICAL CANDIDATE SO THEY WERE MANAGEMENT MEDICALLY. PATIENT HAD THROMBOCYTOPENIA WHICH INCREASED RISK OF BLEEDING. THE PATIENT DIED THREE DAYS POST-PROCEDURE. THE CAUSE OF DEATH WAS DUE TO THE AORTIC DISSECTION AND STROKE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
196240 FLEXNAV DELIVERY SYSTEM AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIVERED NPT ABBOTT MEDICAL 9008369 05415067031372

Patients

Seq Age Sex Outcome Treatment
1 89 YR Female Death