CAPTURA SERRATED FORCEPS WITH SPIKE
Report
- Report Number
- 1037905-2010-00489
- Event Type
- Malfunction
- Date Received
- October 7, 2010
- Date of Event
- September 7, 2010
- Report Date
- September 7, 2010
- Manufacturer
- COOK ENDOSCOPY
- Product Code
- FCL
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- PHYSICIAN
Narratives
EVAL: WE COULD NOT CONFIRM THE REPORT BECAUSE THE PRODUCT SAID TO BE INVOLVED WAS NOT RETURNED TO COOK ENDOSCOPY FOR EVAL. AFTER A REVIEW OF THE DEVICE HISTORY RECORD FOR THE LOT NUMBER SAID TO BE INVOLVED, WE CAN REPORT NO DISCREPANCIES OR ANOMALIES WERE OBSERVED. WE WERE UNABLE TO CONDUCT A SAMPLE TEST FROM THIS LOT BECAUSE NONE OF THE PRODUCT FROM THIS LOT REMAINED IN FINISHED GOODS INVENTORY. A REVIEW OF THE TWELVE COMPLAINT HISTORY FOR THIS PRODUCT FAMILY WAS CONDUCTED. BASED ON THIS REVIEW, THE LIKELIHOOD OF THIS TYPE OF REPORT IS RARE. CONCLUSIONS: WE COULD NOT CONDUCT A COMPLETE INVESTIGATION BECAUSE THE PRODUCT SAID TO BE INVOLVED WAS NOT RETURNED FOR EVAL. A DEFINITIVE CAUSE FOR THE REPORTED OBSERVATION COULD NOT BE DETERMINED. HEMORRHAGE IS LISTED IN THE INSTRUCTIONS FOR USE AS A POTENTIAL COMPLICATION ASSOCIATED WITH GASTROINTESTINAL ENDOSCOPY. IF EXCESSIVE PRESSURE WAS APPLIED DURING ADVANCEMENT INTO THE TISSUE OR DURING HANDLE MANIPULATION, THIS COULD HAVE CONTRIBUTED TO THE REPORTED OBSERVATION. THE INSTRUCTIONS FOR USE DIRECT THE USER TO ADVANCE THE FORCEPS INTO THE TISSUE AT THE DESIRED BIOPSY SITE. THEN THE USER IS INSTRUCTED TO CLOSE THE FORCEPS AROUND THE TISSUE WHILE USING SLIGHT PRESSURE ON THE HANDLE. THE USER IS INSTRUCTED TO MAINTAIN GENTLE HANDLE PRESSURE TO KEEP THE CUPS CLOSED AND GENTLY WITHDRAW THE FORCEPS FROM THE SITE. PRIOR TO DISTRIBUTION, ALL CAPTURA SERRATED FORCEPS WITH SPIKE ARE SUBJECTED TO A VISUAL INSPECTION AND FUNCTIONAL TEST TO ENSURE PROPER WORKABILITY. A REVIEW OF THE DEVICE HISTORY RECORD CONFIRMED THAT THE LOT SAID TO BE INVOLVED MET ALL MFG REQUIREMENTS PRIOR TO SHIPMENT. CORRECTIVE ACTION: NO CORRECTIVE ACTION WARRANTED AT THIS TIME BECAUSE, THE REPORT WAS UNABLE TO BE VERIFIED. THE COMPLAINT RISK PRIORITY NUMBER (CRPN) FOR THIS TYPE OF OCCURRENCE HAS BEEN CALCULATED BASED ON THE RATE OF OCCURRENCE AND SEVERITY OF THE OUTCOME. BASED ON THIS REVIEW, NO FURTHER ACTION IS WARRANTED AT THIS TIME. THE LIKELIHOOD OF THIS TYPE OF OCCURRENCE IS RARE. CUSTOMER QUALITY ASSURANCE WILL CONTINUE TO MONITOR FOR COMPLAINT TRENDS.
THE INFO RELATED TO THIS OCCURRENCE WAS PROVIDED TO COOK VIA COMPLETION OF A MARKETING EVAL QUESTIONNAIRE BY THE INITIAL RPTR. ACCORDING TO THE QUESTIONNAIRE, THE INITIAL RPTR CURRENTLY USES/PREFERS OLYMPUS BRAND OF FORCEPS. DURING A COLONOSCOPY PROCEDURE, THE PHYSICIAN USED A COOK ENDOSCOPY CAPTURA SERRATED FORCEPS WITH SPIKE. THE USER INDICATED THEY ARE SATISFIED WITH EASE OF JAW OPERATION AND TISSUE ACQUISITION. HOWEVER, THE ADD'L COMMENTS SECTION OF THE QUESTIONNAIRE INDICATED THE FORCEPS TOOK TWO ACCEPTABLE BIOPSIES BUT REPORTEDLY OOZED MORE BLOOD THAN THE CURRENT FORCEPS USED (I.E. OLYMPUS BRAND). A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PT'S BODY. THE PT DID NOT REQUIRE ANY ADD'L PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL RPTR, THE PT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | CAPTURA SERRATED FORCEPS WITH SPIKE | FCL, FORCEPS, BIOPSY, NON-ELECTRIC | FCL | COOK ENDOSCOPY | W2897436 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | OLYMPUS GIF H180 ENDOSCOPE |