FDA Adverse Event Malfunction Summary report: N

BD VACUTAINER® PUSH BUTTON BLOOD COLLECTION SET

MDR report key: 18784536 · Received February 26, 2024

Report

Report Number
9617032-2024-00248
Event Type
Malfunction
Date Received
February 26, 2024
Date of Event
February 5, 2024
Report Date
May 9, 2024
Manufacturer
BECTON, DICKINSON AND COMPANY (BD)
Product Code
FPA
UDI-DI
50382903673440
PMA / PMN Number
K030573
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IT
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

H.6 INVESTIGATION SUMMARY : MATERIAL #: 367344, LOT/BATCH #: 3173409. BD HAD NOT RECEIVED SAMPLES, BUT ONE PHOTO WAS PROVIDED FOR INVESTIGATION. THE PHOTO WAS REVIEWED AND THE INDICATED FAILURE MODE FOR HOLDER SEPARATES DURING USE WAS OBSERVED. ADDITIONALLY, TEN RETENTION SAMPLES FROM BD INVENTORY WERE EVALUATED BY FUNCTIONAL TESTING, EACH USED TO DRAW 6 VACUTAINERS WITH WATER AND THE ISSUE OF SEPARATE DURING USE WAS NOT OBSERVED. BASED ON A REVIEW OF THE DEVICE HISTORY RECORD FOR THE INCIDENT LOT, ALL PRODUCT SPECIFICATIONS AND REQUIREMENTS FOR LOT RELEASE WERE MET. THERE WERE NO RELATED QUALITY ISSUES DURING MANUFACTURING OF THE PRODUCT. THIS COMPLAINT HAS BEEN CONFIRMED FOR THE INDICATED FAILURE MODE OF THE HOLDER SEPARATE DURING USE. BD WAS NOT ABLE TO IDENTIFY A ROOT CAUSE FOR THE INDICATED FAILURE MODE. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. H3 OTHER TEXT : SEE H .10.

Additional Manufacturer Narrative · 0

D2A. COMMON DEVICE NAME: BLOOD SPECIMEN COLLECTION DEVICE; INTRAVASCULAR ADMINISTRATION SET D2B.MEDICAL DEVICE TYPE: JKA THERE WERE MULTIPLE 510K NUMBERS REPORTED TO BE INVOLVED. THE INFORMATION IS AS FOLLOWS: G.5. PMA / 510(K)#: K220212 H.3. A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 0

IT WAS REPORTED THAT WHILE USING BD VACUTAINER® PUSH BUTTON BLOOD COLLECTION SET, THE HOLDER SEPARATED FROM THE NEEDLE. NO PATIENT IMPACT REPORTED.

Description of Event or Problem · 0

IT WAS REPORTED THAT WHILE USING BD VACUTAINER® PUSH BUTTON BLOOD COLLECTION SET, THE HOLDER SEPARATED FROM THE NEEDLE. NO PATIENT IMPACT REPORTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
120363 BD VACUTAINER® PUSH BUTTON BLOOD COLLECTION SET SEE H.10 FPA BECTON, DICKINSON AND COMPANY (BD) 3173409 50382903673440

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown