FDA Adverse Event Malfunction Summary report: N

TRUE METRIX

MDR report key: 18686564 · Received February 12, 2024

Report

Report Number
1000113657-2024-00059
Event Type
Malfunction
Date Received
February 12, 2024
Date of Event
January 18, 2024
Report Date
February 12, 2024
Manufacturer
TRIVIDIA HEALTH INC
Product Code
NBW
UDI-DI
00021292007836
PMA / PMN Number
K140100
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MI, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

INTERNAL COMPLAINT REFERENCE: CASE-(B)(4). TEST STRIPS WERE NOT RETURNED FOR EVALUATION. METER WAS RETURNED-REPORTED DEFECT NOT REPRODUCED ON RETURNED METER. RETENTION TESTING WAS PERFORMED USING TEST STRIPS FROM THE SAME LOT. RETENTION STRIP LOT PASSED WITHIN SPECIFICATIONS. MOST LIKELY UNDERLYING ROOT CAUSE: MLC-055: USER HAD AN INACCURATE REFERENCE: COMPETITOR¿S METER: THE END USER IS COMPARING RESULTS OBTAINED FROM TRIVIDIA¿S BGM SYSTEM TO THE RESULTS FROM A COMPETITOR¿S BGM SYSTEM. NOTE: MANUFACTURER CONTACTED CUSTOMER IN A FOLLOW-UP CALL ON 30-JAN-2023 TO ENSURE AND TO ENSURE THE CUSTOMER¿S INITIAL CONCERN WAS RESOLVED- CUSTOMER STATES SHE IS COMFORTABLE WITH THE GLUCOSE READINGS FROM THE REPLACEMENT PRODUCTS.

Description of Event or Problem · 0

CONSUMER REPORTED COMPLAINT FOR LOW BLOOD GLUCOSE TEST RESULTS. CONSUMER IS CONCERNED WITH TEST RESULTS FROM METER TO METER COMPARISON. CUSTOMER STATED THAT LAST WEEK SHE TESTED HER BLOOD SUGAR AT 8:00 AM WITH THE TRUE METRIX AND RESULT WAS 112 MG/DL AND 30 MINUTES LATER SHE WENT TO HER REGULAR CHECKUP APPOINTMENT AND DOCTOR TESTED WITH THEIR BGM AND RESULT WAS 320 MG/DL AM FASTING. THE CUSTOMER¿S EXPECTED AM FASTING BLOOD GLUCOSE TEST RESULT RANGE IS 120-174 MG/DL. THE CUSTOMER FEELS WELL AND DID NOT REPORT ANY SYMPTOMS. MEDICAL ATTENTION IS NOT REPORTED AS A RESULT OF THE ACTUAL BLOOD GLUCOSE RESULTS. DURING THE CALL, A BACK TO BACK BLOOD TEST WAS NOT PERFORMED BY THE CUSTOMER. THE PRODUCT IS STORED ACCORDING TO SPECIFICATION IN THE BEDROOM. THE TEST STRIP LOT MANUFACTURER¿S EXPIRATION DATE IS 02/18/2025 AND OPEN VIAL DATE IS 2 WEEKS AGO. THE METER MEMORY WAS REVIEWED FOR PREVIOUS TEST RESULT HISTORY: RESULT 1: 112MG/DL DATE: 1/12 TIME: 8:00AM FASTING. RESULT 2: 170MG/DL DATE: 1/11 TIME: 8:00AM FASTING RESULT 3: 141MG/DL DATE: 1/10 TIME: 8:00AM FASTING RESULT 4: 134MG/DL DATE: 1/09 TIME: 8:00AM FASTING RESULT 5: 136MG/DL DATE: 1/08 TIME: 8:00AM FASTING

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1067523 TRUE METRIX SYSTEM, TEST BLOOD GLUCOSE, OVER THE COUNTER NBW TRIVIDIA HEALTH INC STRIP, TRUE METRIX 50CTMG/DL ZB5331S 00021292007836

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown