FDA Adverse Event Injury Summary report: N

EDWARDS SAPIEN 3 ULTRA TRANSCATHETER HEART VALVE

MDR report key: 18677597 · Received February 9, 2024

Report

Report Number
2015691-2024-00888
Event Type
Injury
Date Received
February 9, 2024
Date of Event
January 1, 2023
Report Date
February 9, 2024
Manufacturer
EDWARDS LIFESCIENCES
Product Code
NPT
PMA / PMN Number
P140031
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
GA, US
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

ARTICLE REFERENCE: UEYAMA, H. A., XIE, J., HANZEL, G. S., BYKU, I., PAONE, G., GRUBB, K. J., DEVIREDDY, C. M., GREENBAUM, A. B., BABALIAROS, V. C., & GLEASON, P. T. (2024). HEMODYNAMIC COMPARISON OF RESILIA AND SAPIEN 3/ULTRA TRANSCATHETER HEART VALVES IN TRANSCATHETER AORTIC VALVE REPLACEMENT. CIRCULATION. CARDIOVASCULAR INTERVENTIONS, 17(1), E013325. PER THE INSTRUCTIONS FOR USE (IFU), PERMANENT OR TRANSIENT NEUROLOGICAL EVENTS INCLUDING STROKE ARE POTENTIAL ADVERSE EVENTS ASSOCIATED WITH THE TAVR PROCEDURE AND THE USE OF THE EDWARDS THV DEVICES. ACCORDING TO LITERATURE REVIEW, AND AS DOCUMENTED IN A CLINICAL TECHNICAL SUMMARY, STROKE IS RECOGNIZED IN THE LITERATURE AS A WELL-KNOWN COMPLICATION IN A SMALL NUMBER OF PATIENTS UNDERGOING TAVR. RISK FACTORS CORRELATING WITH A NUMBER OF PATIENT CO-MORBIDITIES HAVE BEEN IDENTIFIED. ALTHOUGH IN MANY CASES THE ROOT CAUSE OF THE EVENT IS UNABLE TO BE DETERMINED, STROKES DURING TAVR ARE UNDOUBTEDLY MULTIFACTORIAL, THE DOMINANT ETIOLOGY LIKELY BEING INTRA-PROCEDURE EMBOLIC EVENTS. A TRANSCRANIAL DOPPLER STUDY DURING TAVR DEMONSTRATED THAT THE MAJORITY OF PROCEDURAL EMBOLIC EVENTS OCCURRED DURING BALLOON VALVULOPLASTY, MANIPULATION OF CATHETERS ACROSS THE AORTIC VALVE, AND VALVE IMPLANTATION. AN ANALYSIS IN PATIENTS UNDERGOING VALVE SURGERY REVEALED FOUR BASELINE CHARACTERISTICS AND TWO PROCEDURAL EVENTS THAT WERE ASSOCIATED WITH EARLY POST-PROCEDURE STROKE: FEMALE SEX, EF < 30%, DIABETES, AGE OLDER THAN 70 YEARS, BYPASS PROCEDURE TIME> 120 MIN, AND CALCIFICATION OF THE ASCENDING AORTA. PREDICTORS OF LATE STROKE HAVE INCLUDED FEMALE SEX, AGE OLDER THAN 75 YEARS, ATRIAL FIBRILLATION, AND A HISTORY OF OR CURRENT SMOKING. THERE WERE NO IMPORTANT DIFFERENCES IN THE FREQUENCY OF LATE STROKES BETWEEN TAVR AND AVR PATIENTS. AFTER TAVR, THERE APPEARS TO BE A MORE SIGNIFICANT PROPORTION OF EARLY STROKES OCCURRING < 24 H POST-PROCEDURE, BUT TAVR PATIENTS WITH MULTIPLE CO MORBIDITIES ARE PROBABLY AT HIGHER RISK OF BOTH EARLY AND LATE STROKES. IN THIS CASE, THERE WAS NO ALLEGATION OR INDICATION A DEVICE MALFUNCTION CONTRIBUTED TO THIS ADVERSE EVENT. WITH THE LIMITED INFORMATION THE CAUSE OF THE STROKE IS UNKNOWN BUT MAY BE RELATED TO THE MECHANISMS ABOVE. THE IFU AND TRAINING MANUALS HAVE BEEN REVIEWED AND NO INADEQUACIES HAVE BEEN IDENTIFIED WITH REGARDS TO WARNINGS, CONTRAINDICATIONS, AND THE DIRECTIONS/CONDITIONS FOR THE SUCCESSFUL USE OF THE DEVICE. COMPLAINT HISTORIES FOR ALL REPORTED EVENTS ARE REVIEWED AGAINST TRENDING CONTROL LIMITS ON A MONTHLY BASIS, AND ANY EXCURSIONS ABOVE THE CONTROL LIMITS ARE ASSESSED AND DOCUMENTED AS PART OF THIS MONTHLY REVIEW. NO CORRECTIVE OR PREVENTATIVE ACTIONS ARE REQUIRED.

Description of Event or Problem · 0

AS REPORTED, PER ARTICLE "HEMODYNAMIC COMPARISON OF RESILIA AND SAPIEN 3/ULTRA TRANSCATHETER HEART VALVES IN TRANSCATHETER AORTIC VALVE REPLACEMENT", THE FOLLOWING EVENTS WERE NOTED AT 30 DAYS: 4 PATIENTS WITH SAPIEN 3 ULTRA VALVES HAD STROKE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1379560 EDWARDS SAPIEN 3 ULTRA TRANSCATHETER HEART VALVE AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIVERED NPT EDWARDS LIFESCIENCES 9750TFX N/A

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Other