FDA Adverse Event Injury Summary report: N

REGALIA XS 1.0

MDR report key: 18655965 · Received February 6, 2024

Report

Report Number
3003775027-2024-00016
Event Type
Injury
Date Received
February 6, 2024
Date of Event
January 4, 2024
Report Date
February 7, 2024
Manufacturer
ASAHI INTECC CO., LTD.
Product Code
DQX
PMA / PMN Number
K163426
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

MANUFACTURING SITE: TOYOFLEX CEBU CORPORATION, CEBU, PHILIPPINES, REGISTRATION NUMBER: 3016119728. WHEN THE REPORTED PRODUCT WAS RETURNED TO THE MANUFACTURER, REPORTABLE MALFUNCTION WAS RECOGNIZED FOR THE FIRST TIME; THEREFORE, G3. DATE RECEIVED BY MANUFACTURER IS THE SAME AS THE DATE IN D9. RETURNED TO MANUFACTURER. THE REPORTED REGALIA XS 1.0 GUIDE WIRE WAS RETURNED FOR EVALUATION. AT APPROXIMATELY 160MM FROM THE TIP, THE GUIDE WIRE WAS CURVED AND THE POLYMER JACKET WAS TORN OFF. PEELING OF THE POLYMER JACKET WAS FOUND AT APPROXIMATELY 150-160MM FROM THE TIP, EXPOSING THE CORE SHAFT. (SEGMENT A) ANOTHER CURVE WAS OBSERVED ON THE RETURNED GUIDE WIRE AT APPROXIMATELY 130MM FROM THE TIP, WHERE THE POLYMER JACKET WAS ALSO TORN OFF. PEELING OF THE POLYMER JACKET WAS FOUND AT APPROXIMATELY 120-130MM FROM THE TIP, EXPOSING THE CORE SHAFT. (SEGMENT B) MICROSCOPIC OBSERVATION OF SEGMENT A FOUND THAT THE TORN END OF THE POLYMER JACKET WAS STRETCHED BY TENSILE STRESS. THE POLYMER JACKET AT APPROXIMATELY 150-160MM FROM THE TIP WAS FOUND FLIPPED OVER DISTALLY FROM THE TORN END. AS SEEN ON SEGMENT A, THE TORN END OF THE POLYMER JACKET ON SEGMENT B WAS ALSO STRETCHED BY TENSILE STRESS. THE POLYMER JACKET AT APPROXIMATELY 120-130MM FROM THE TIP WAS FOUND FLIPPED OVER DISTALLY FROM THE TORN END. LOT HISTORY REVIEW REVEALED NO ANOMALY RELATING TO THE REPORTED EVENT. NO OTHER SIMILAR PRODUCT EXPERIENCE REPORT WAS RECEIVED FROM THIS LOT. BASED ON THE OBTAINED INFORMATION AND INVESTIGATION OUTCOME, IT WAS PRESUMED THAT THE POLYMER JACKET OF THE REGALIA XS 1.0 GUIDE WIRE MIGHT HAVE BEEN SCRAPED AND DAMAGED BY WIRE MANIPULATION APPLIED WHEN THE WIRE TIP WAS TEMPORARILY CAUGHT DUE TO ANATOMICAL CONDITIONS. FURTHER APPLIED TENSILE STRESS GENERATED WITH REMOVAL THEN MADE THE POLYMER JACKET STRETCH, TEAR AND THEN PEEL OFF. IT WAS CONCLUDED THAT THIS EVENT WAS NOT ATTRIBUTED TO PRODUCT QUALITY. GIVEN THE DAMAGE OBSERVED ON THE RETURNED GUIDE WIRE, IT WAS UNABLE TO COMPLETELY RULE OUT A POSSIBILITY THAT SOME POLYMER JACKET FRAGMENT(S) MIGHT BE LEFT IN THE PATIENT ANATOMY. NO CAPA WILL BE TAKEN. INSTRUCTIONS FOR USE (IFU) STATES: [WARNINGS] OBSERVE MOVEMENT OF THIS GUIDE WIRE IN THE VESSELS. BEFORE THIS GUIDE WIRE IS MOVED OR TORQUED, THE TIP MOVEMENT SHOULD BE EXAMINED AND MONITORED UNDER FLUOROSCOPY. DO NOT MOVE OR TORQUE THE GUIDE WIRE WITHOUT OBSERVING CORRESPONDING MOVEMENT OF THE TIP; OTHERWISE, THE GUIDE WIRE MAY BE DAMAGED AND/OR TRAUMA MAY OCCUR. IN ADDITION, ENSURE THAT THE DISTAL TIP OF THIS GUIDE WIRE AND ITS LOCATION IN THE VESSEL ARE VISIBLE DURING MANIPULATIONS OF THE GUIDE WIRE. IF RESISTANCE IS FELT DUE TO SPASM, BENDING OF THE GUIDE WIRE, OR DUE TO TRAP WHILE OPERATING THIS GUIDE WIRE IN THE BLOOD VESSEL OR REMOVING IT, DO NOT TORQUE AND/OR PULL THE GUIDE WIRE ITSELF. STOP THE PROCEDURE. DETERMINE THE CAUSE OF RESISTANCE UNDER FLUOROSCOPY AND TAKE APPROPRIATE REMEDIAL ACTION. IF THE GUIDE WIRE IS MOVED EXCESSIVELY, IT MAY BREAK OR BECOME DAMAGED, WHICH MAY CAUSE BLOOD VESSEL INJURY OR RESULT IN FRAGMENTS BEING LEFT INSIDE THE VESSEL. [MALFUNCTION AND ADVERSE EFFECTS] BREAKAGE OF THE GUIDE WIRE.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE POLYMER JACKET ON THE TIP OF AN ASAHI REGALIA XS 1.0 GUIDE WIRE WAS DISARRANGED WHEN THE GUIDE WIRE WAS USED DURING A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY FOR SHUNT. A NEW REGALIA XS 1.0 GUIDE WIRE WAS THEN USED TO SUCCESSFULLY COMPLETE THE ANGIOPLASTY FOR SHUNT. IT WAS INFORMED THAT THERE WERE NO ADVERSE PATIENT EFFECTS AND THE PATIENT HAD NO PROBLEMS AFTER THE PROCEDURE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1907137 REGALIA XS 1.0 PERIPHERAL GUIDE WIRE DQX ASAHI INTECC CO., LTD. NA 230916A05F

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Other