WATCHMAN LAA CLOSURE DEVICE & DELIVERY SYSTEM
Report
- Report Number
- 2124215-2024-02177
- Event Type
- Injury
- Date Received
- January 29, 2024
- Date of Event
- November 1, 2014
- Report Date
- January 29, 2024
- Manufacturer
- BOSTON SCIENTIFIC CORPORATION
- Product Code
- NGV
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- BE
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
B3: DATE OF EVENT - ESTIMATED AS 01NOV2014 AS THE DATE RANGE IS FROM NOVEMBER 2014 TO APRIL 2022. 4 WATCHMAN FLX AND 2 WATCHMAN 2.5 COMPLAINT EVENTS WERE OPENED FOR BELGIUM BASED ON REVIEW OF THE ATTACHED LITERATURE ARTICLE PER THE LOCATION OF THE LEAD AUTHOR AS THE DETAILS OF WHERE EACH EVENT OCCURRED WERE NOT SPECIFIED; IF ADDITIONAL INFORMATION IS RECEIVED A LATER DATE, IT WILL BE REVIEWED AT THAT TIME. 8 WATCHMAN FLX AND 1 WATCHMAN 2.5 WERE IDENTIFIED AS DUPLICATES TO EXISTING COMPLAINTS. LITERATURE CITATION: AMINIAN A, LEDUC N, FREIXA X, SWAANS MJ, BEN YEDDER M, MAARSE M, SANCHIS L, CEPAS-GUILLEN P, CRUZ-GONZALEZ I, BLANCO-FERNANDEZ F, ESCHALIER R, BOERSMA LVA. LEFT ATRIAL APPENDAGE OCCLUSION UNDER MINIATURIZED TRANSESOPHAGEAL ECHOCARDIOGRAPHIC GUIDANCE AND CONSCIOUS SEDATION: MULTICENTER EUROPEAN EXPERIENCE. JACC CARDIOVASC INTERV. 2023 AUG 14;16(15):1889-1898. DOI: 10.1016/J.JCIN.2023.06.007. PMID: 37587597.
IT WAS REPORTED VIA LITERATURE THAT THROMBOSIS OCCURRED. LEFT ATRIAL APPENDAGE OCCLUSION (LAAO) PROCEDURES WERE PERFORMED WITH MINIATURIZED TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE) PROBES FOR 546 PATIENTS BETWEEN (B)(6) 2014 AND (B)(6) 2022. OF THE IMPLANTED DEVICES FROM THE STUDY, 301 WERE ATTRIBUTED TO THE WATCHMAN PRODUCT. THE PRESENCE OF DEVICE RELATED THROMBUS WAS DETECTED IN 21 PATIENTS IN THE STUDY. 13 CASES WERE DETECTED BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE), 4 CASES WERE DETECTED BY COMPUTED TOMOGRAPHY (CT), AND 4 CASES WERE DETECTED BY BOTH TEE AND CT. DEVICE RELATED THROMBUS OCCURRED ON A WATCHMAN 2.5 CLOSURE DEVICE IN 3 CASES AND A WATCHMAN FLX CLOSURE DEVICE IN 12 CASES. THE OTHER CASES WERE NON-BOSTON SCIENTIFIC PRODUCTS. THE MEDIAN DAYS TO IMAGING FOLLOW UP WAS 64 DAYS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 825752 | WATCHMAN LAA CLOSURE DEVICE & DELIVERY SYSTEM | SYSTEM, APPENDAGE CLOSURE, LEFT ATRIAL | NGV | BOSTON SCIENTIFIC CORPORATION |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown | Other |