FDA Adverse Event Injury Summary report: N

MICRA

MDR report key: 18573523 · Received January 24, 2024

Report

Report Number
9612164-2024-00407
Event Type
Injury
Date Received
January 24, 2024
Date of Event
January 1, 2024
Report Date
January 24, 2024
Manufacturer
MEDTRONIC IRELAND
Product Code
DYB
PMA / PMN Number
K132030
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
GA, US
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THIS INFORMATION IS BASED ENTIRELY ON JOURNAL LITERATURE. MEDTRONIC WAS MADE AWARE OF THIS EVENT THROUGH A SEARCH OF LITERATURE PUBLICATIONS. OF NOTE, MULTIPLE PATIENTS AND MULTIPLE MANUFACTURERS WERE NOTED IN THE ARTICLE; HOWEVER, A ONE-TO-ONE CORRELATION COULD NOT BE MADE WITH UNIQUE PRODUCT SERIAL/LOT NUMBERS. THE BASELINE GENDER/AGE CHARACTERISTICS IS MALE/80 YEARS OLD. THE MODEL LISTED IN THE REPORT IS A REPRESENTATIVE OF THE MODEL FAMILY, AS THERE IS NO SPECIFIC MODEL LISTED. WITHOUT A LOT NUMBER OR DEVICE SERIAL NUMBER, THE MANUFACTURING DATE CANNOT BE DETERMINED. SINCE NO DEVICE ID WAS PROVIDED, IT IS UNKNOWN IF THIS EVENT HAS BEEN PREVIOUSLY REPORTED. REFERENCED ARTICLE: GENDER DIFFERENCES WITH LEADLESS PACEMAKERS: PERIPROCEDURAL COMPLICATIONS, LONG-TERM DEVICE FUNCTION, AND CLINICAL OUTCOMES. THE AMERICAN JOURNAL OF CARDIOLOGY. 2024. 210, 229¿231. DOI: 10.1016/J.AMJCARD.2023.10.048 MEDTRONIC IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ¿DEFECTS¿ OR HAS ¿MALFUNCTIONED¿. THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REGULATORY REPORTING. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE THEM BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 0

LITERATURE WAS REVIEWED REGARDING GENDER DIFFERENCES IN PATIENTS WITH LEADLESS IMPLANTABLE PULSE GENERATORS (IPGS). THE AUTHORS DESCRIBED PATIENT DEATHS; HOWEVER, THE CAUSES OF DEATH WERE UNKNOWN AND DEFINED AS 30-DAY ALL-CAUSE MORTALITY. THE DEATHS WITHIN 30 DAYS OF IMPLANT WERE NOT BELIEVED TO BE DIRECTLY RELATED TO THE LEADLESS IPG IMPLANTS, BUT IT IS UNKNOWN. THERE WAS ONE PATIENT WHO EXPERIENCED A CARDIAC PERFORATION AND UNDERWENT EMERGENT SURGICAL REPAIR OF THE RIGHT VENTRICLE AND DIED AFTER A PROLONGED HOSPITAL COURSE. THERE WERE PATIENTS WHO EXPERIENCED CARDIAC PERFORATIONS WHICH REQUIRED PERICARDIOCENTESIS, AND ONE PATIENT DEVELOPED A PERICARDIAL EFFUSION DURING THE LEADLESS IPG IMPLANT, AND THE IMPLANT WAS ABORTED, BUT THEY LATER WERE IMPLANTED WITH A TRANSVENOUS IPG. OTHER PATIENTS EXPERIENCED ACCESS SITE HEMATOMAS WHICH REQUIRED INTERVENTION, PSEUDOANEURYSMS, AND 30-DAY REHOSPITALIZATIONS FOR UNKNOWN REASONS. THE LEADLESS IPGS EXHIBITED AN INCREASE IN CAPTURE THRESHOLDS AND DECREASES IN PACING IMPEDANCE. THE STATUS OF THE DEVICES IS UNKNOWN. NO ADDITIONAL ADVERSE PATIENT EFFECTS OR PRODUCT PERFORMANCE ISSUES WERE REPORTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1056566 MICRA INTRODUCER, CATHETER DYB MEDTRONIC IRELAND MI2355A

Patients

Seq Age Sex Outcome Treatment
1 80 YR Male