FDA Adverse Event Injury Summary report: N

CENTURION VISION SYSTEM, ACCESSORY, ACTIVE SENTRY HANDPIECE

MDR report key: 18550735 · Received January 22, 2024

Report

Report Number
2028159-2024-00106
Event Type
Injury
Date Received
January 22, 2024
Report Date
June 11, 2024
Manufacturer
ALCON RESEARCH, LLC - IRVINE TECHNOLOGY CENTER
Product Code
HQC
UDI-DI
00380657529148
PMA / PMN Number
K161794
Removal / Correction Number
NA
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
RP
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THE MANUFACTURER INTERNAL REFERENCE NUMBER IS: (B)(4).

Additional Manufacturer Narrative · 0

INVESTIGATION INCLUDING ROOT CAUSE ANALYSIS IS IN PROGRESS. A SUPPLEMENTAL MDR WILL BE FILED AS NECESSARY IN ACCORDANCE WITH 21 CFR 803.56 WHEN ADDITIONAL REPORTABLE INFORMATION BECOMES AVAILABLE. THE MANUFACTURER INTERNAL REFERENCE NUMBER IS: (B)(4).

Additional Manufacturer Narrative · 0

ADDITIONAL INFORMATION PROVIDED IN SECTIONS D.9. H.3. H.6 AND H.11. THE PRODUCT UNDER INVESTIGATION IS NOT A SERVICEABLE DEVICE. THEREFORE, A SERVICE RECORD REVIEW WAS NOT PERFORMED. HOWEVER, A HANDPIECE (HP) WAS RETURNED FOR THIS INVESTIGATION. A NON-CONFORMANCE BASED REVIEW OF THE SERIAL NUMBER WAS PERFORMED AND DID NOT REVEAL ANY POTENTIAL CONTRIBUTING FACTORS TO THE REPORTED COMPLAINT. A MANUFACTURING DEVICE HISTORY RECORD (DHR) REVIEW WAS PERFORMED PRIOR TO PRODUCT RELEASE TO ENSURE THAT THE PRODUCT WAS MANUFACTURED IN COMPLIANCE WITH THE DEVICE MASTER RECORD. BASED ON THE ASSESSMENT, THE PRODUCT MET RELEASE CRITERIA. A REVIEW FOR COMPLAINTS REPORTED AGAINST THIS SERIAL NUMBER WAS PERFORMED. QUALITY SUMMARIES (QS¿S) WERE OPENED FOR THE EVENTS THAT OCCURRED WITH THE DEMO AND REPLACEMENT SYSTEMS, AND AT OTHER DATES WITH DIFFERENT PATIENTS. THE INVESTIGATIONS WILL MIRROR THIS INVESTIGATION. THE INVESTIGATION LOGS FOR THE HANDPIECE ARE DOCUMENTED IN THE FIRST QS OPENED. THE HP WAS RECEIVED FOR TESTING ON THIS INVESTIGATION. A VISUAL ASSESSMENT OF THE RETURNED SAMPLE REVEALED NO OBVIOUS NON-CONFORMITIES. THE HANDPIECE WAS CONNECTED TO A CALIBRATED RESISTANCE BREAKOUT TEST BOX, WHERE THE CONNECTION BETWEEN THE INPUT AND OUTPUT IMPEDANCE OF THE SENSOR WAS FOUND TO BE WITHIN SPECIFICATIONS. WHEN THE HANDPIECE WAS CONNECTED TO A CALIBRATED BREAKOUT TEST BOX, BOTH THE RESISTANCE AND DISSIPATION BETWEEN LOW ELECTRODE AND HIGH ELECTRODE WERE FOUND TO BE OUT OF SPECIFICATIONS. A FLOW RATE TEST WAS PERFORMED ON THE IRRIGATION AND ASPIRATION LINES OF THE HANDPIECE WHICH FOUND THE HANDPIECE TO FAIL SPECIFICATIONS. THE HANDPIECE CHANNELS WERE INSPECTED WITH A BORESCOPE WHICH REVEALED NO OBVIOUS NONCONFORMITIES. THE RETURNED SAMPLE WAS CONNECTED TO A CALIBRATED SYSTEM. THE HANDPIECE TUNED SUCCESSFULLY AND COMPLETED A FIVE-MINUTE BURN-IN TEST WITH THE SYSTEM SET AT 100% ULTRASONIC AND TORSIONAL POWER. THE HANDPIECE WAS CONNECTED TO DYNAMIC TUNING FIXTURE (DTF) FOR STROKE LENGTH TESTING ON THE LONGITUDINAL AND TORSIONAL MOVEMENTS WHICH FOUND THE HANDPIECE TO MEET SPECIFICATIONS. HOWEVER, AS THE BORESCOPE TEST DID NOT REVEAL ANY NONCONFORMITIES, A SECOND SET OF A VISUAL AND FUNCTIONAL ASSESSMENTS WERE PERFORMED ON THE HANDPIECE TO CONFIRM THE PRIOR RESULTS. A PARTICULATE TEST WAS PERFORMED IN WHICH NO PARTICLES WERE FOUND. THE HANDPIECE WAS CONNECTED TO A CALIBRATED RESISTANCE BREAKOUT TEST BOX, WHERE THE CONNECTION BETWEEN THE INPUT AND OUTPUT IMPEDANCE OF THE SENSOR WAS FOUND TO BE WITHIN SPECIFICATIONS. WHEN THE HANDPIECE WAS CONNECTED TO A CALIBRATED BREAKOUT TEST BOX, THE RESISTANCE BETWEEN LOW ELECTRODE AND HIGH ELECTRODE WAS FOUND TO BE OUT OF SPECIFICATIONS. A FLOW RATE TEST WAS PERFORMED ON THE IRRIGATION AND ASPIRATION LINES OF THE HANDPIECE WHICH FOUND THE HANDPIECE TO THEN MEET SPECIFICATIONS PER PRODUCT SPECIFICATIONS. WHEN CONNECTED TO A CALIBRATED SYSTEM, THE HANDPIECE TUNED SUCCESSFULLY AND COMPLETED A FIVE-MINUTE BURN-IN TEST WITH THE SYSTEM SET AT 100% ULTRASONIC AND TORSIONAL POWER. THE HANDPIECE WAS CONNECTED TO DTF FOR STROKE LENGTH TESTING ON THE LONGITUDINAL AND TORSIONAL MOVEMENTS WHICH FOUND THE HANDPIECE TO MEET SPECIFICATIONS. THE NONCONFORMING SPECIFICATIONS RELATED TO RESISTANCE, DISSIPATION, AND FLOW ARE NOT RELATED TO THE REPORTED CORNEAL EDEMA. THE CUSTOMER REPORTED EVENT WAS NOT ABLE TO BE CONFIRMED. BASED ON THE INFORMATION OBTAINED, THE ROOT CAUSE OF THE REPORTED EVENTS IS INCONCLUSIVE. MANUFACTURER WILL CONTINUE TO MONITOR DATA FOR EVIDENCE OF ADVERSE TRENDING AND TAKE FURTHER ACTION, AS APPROPRIATE. THE MANUFACTURER INTERNAL REFERENCE NUMBER IS: (B)(4). H.10 REFLECTS ALL RELATED REPORT NUMBERS ASSOCIATED WITH THIS PRODUCT EVENT THAT HAVE BEEN SUBMITTED AT THIS TIME.

Description of Event or Problem · 0

A PHYSICIAN REPORTED THAT A PATIENT WITH A GRADE THREE CATARACT UNDERWENT CATARACT SURGERY WITH MONOFOCAL LENS IMPLANTATION USING AN OPHTHALMIC OPERATING HANDPIECE. AT ONE-WEEK POST-OP, THE PATIENT EXHIBITED CORNEAL EDEMA WITH VISUAL DISTURBANCE IN THE LEFT EYE, FOR WHICH THE PATIENT WAS TREATED WITH CORTICOSTEROIDS EYE DROPS. THE PHYSICIAN SAW THE PATIENT AT THREE MONTHS FOLLOW UP FROM PROCEDURE AND IT WAS OBSERVED THAT THE PATIENT HAD NOT YET RECOVERED. IN THE FOURTH MONTH PATIENT WAS FULLY RECOVERED. THIS COMPLAINT IS PERTAINING THE FIRST OF TWO REPORTS RECEIVED FROM THE INITIAL REPORTER.

Description of Event or Problem · 0

A HEALTHCARE PROFESSIONAL REPORTED THAT AFTER USING OPHTHALMIC HANDPIECE AND CONSOLE IN A CATARACT SURGERIES PATIENT EXPERIENCED CORNEAL EDEMA WITH CORNEAL OPACITY AFTER TWO WEEKS POST OPERATION AND IT LEAD TO LOSS OF BEST CORRECTED VISUAL ACUITY. THE PATIENT'S CURRENT CONDITIONS WERE IMPROVING SLOWLY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1717632 CENTURION VISION SYSTEM, ACCESSORY, ACTIVE SENTRY HANDPIECE UNIT, PHACOFRAGMENTATION HQC ALCON RESEARCH, LLC - IRVINE TECHNOLOGY CENTER NA 15PJH6 00380657529148

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Required Intervention| O CENTURION VISION SYSTEM (ACTIVE SENTRY)