COSYCOT INFANT WARMER
Report
- Report Number
- 9611451-2010-00595
- Event Type
- Malfunction
- Date Received
- October 3, 2010
- Date of Event
- September 9, 2010
- Report Date
- September 9, 2010
- Manufacturer
- FISHER & PAYKEL HEALTHCARE LIMITED
- Product Code
- FMT
- PMA / PMN Number
- K971695
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- BIOMEDICAL ENGINEER
Narratives
THE COMPLAINT DEVICE IS CURRENTLY EN ROUTE TO FISHER & PAYKEL HEALTHCARE'S REGIONAL OFFICE AND SERVICE CENTER.WE WILL PROVIDE A FOLLOW-UP REPORT UPON RECEIPT OF THE DEVICE AND COMPLETION OF OUR INVESTIGATION.
(B)(4).METHOD: THE COMPLAINT INFANT WARMER BASE WAS RETURNED TO FISHER & PAYKEL HEALTHCARE'S (B)(4). AN INVESTIGATION WAS CARRIED OUT BASED ON PHOTOGRAPHS OF THE DEVICE. RESULTS: THE PLASTIC ON THE BOTTOM EDGE OF ONE OF THE BASE LEGS WAS CHIPPED. THE OPPOSING LEG WAS ALSO FOUND TO BE DAMAGED. THE CIRCLIP PLATE FOR THE BASE FEET WAS OUT OF POSITION. THE CASTOR WAS FURTHER INSPECTED BY THE FISHER & PAYKEL HEALTHCARE SERVICE TECHNICIANS WHO ADVISED THAT THE WHEEL COULD BE ROTATED EVEN WHEN THE BRAKE WAS ENGAGED. A LOT CHECK REVEALED NO OTHER COMPLAINTS OF THIS NATURE FOR LOT NUMBER 050406. CONCLUSION: THE DAMAGE TO THE TWO LEGS IS LIKELY TO HAVE BEEN CAUSED BY REPEATED IMPACT ON THE BASE DUE TO ROUGH HANDLING. THE IW932 IS A MOBILE WARMER AND CAN BE DAMAGED DURING TRANSPORT. IT IS POSSIBLE THAT THE BASE LEGS ENCOUNTERED ACCIDENTAL IMPACT THROUGH COLLISION WITH WALLS OR SWINGING DOORS. THIS DAMAGE IS LIKELY TO HAVE AFFECTED THE CASTOR AS WELL AND WOULD HAVE BEEN EXAGGERATED IF THE UNIT HAD BEEN WHEELED OVER UNEVEN FLOORS DURING ITS FIVE YEARS OF USAGE. A MISALIGNED CASTOR WILL BE EVIDENT TO THE USER AS THIS WILL RESULT ON STEERING PERFORMANCE ISSUE. THE PRODUCT TECHNICAL MANUAL ADVISES THAT THE CASTORS SHOULD BE CHECKED TO ENSURE THAT THEY ROLL AND LOCK PROPERLY AS PART OF THE ANNUAL FUNCTIONAL CHECK. A REPLACEMENT BASE ASSEMBLY HAS BEEN SUPPLIED TO THE CUSTOMER.
A HOSPITAL IN (B)(6) REPORTED THAT THE WHEEL ON AN IW932 COSYCOT INFANT WARMER BASE IS TILTED.THE TILTED WHEEL WAS FOUND BY THE HOSPITAL PRIOR TO PATIENT USE.
A HOSPITAL IN (B)(6) REPORTED THAT THE WHEEL ON AN IW932 COSYCOT INFANT WARMER BASE IS TILTED. THE TILTED WHEEL WAS FOUND BY THE HOSPITAL PRIOR TO PATIENT USE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | COSYCOT INFANT WARMER | FMT | FMT | FISHER & PAYKEL HEALTHCARE LIMITED | IW932JEU | 050406 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |