FDA Adverse Event Malfunction Summary report: N

HAMILTON MEDICAL AG

MDR report key: 18370782 · Received December 21, 2023

Report

Report Number
3001421318-2023-04301
Event Type
Malfunction
Date Received
December 21, 2023
Date of Event
December 5, 2023
Report Date
December 3, 2025
Manufacturer
HAMILTON MEDICAL AG
Product Code
CBK
UDI-DI
07630002808590
PMA / PMN Number
K201658
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IN
Reporter Occupation
003

Narratives

Description of Event or Problem · 0

THE FOLLOWING HAS BEEN REPORTED ZO HAMILTON MEDICAL AG ON DECEMBER 12TH 2023: DURING VENTILATOR TRIAL POTENTIAL CUSTOMER STATES THAT WHEN PATIENT'S NCPAP INTERFACE BECAME DISLODGED FROM PATIENT THERE WAS NO ALARM AVAILABLE TO ALERT THE CLINICIAN. LOW PRESSURE ALARM IS NOT USEFUL AS THE C6'S LEAK COMPENSATION DID NOT ALLOW PRESSURE TO DROP. THIS EVENT REQUIRED MEDICAL INTERVENTION : HYPEROXYGENATED TO COMPENSATE FOR DROPPED SATURATIONS NO INDICATION THAT THE COMPLAINT LEAD TO DEATH, INJURY OR SERIOUS DETERIORATION OF THE HEALTH OF THE PATIENT, USER OR THIRD-PARTY. PRELIMINARY ANALYSIS OF THE LOG FILE REVEALED THE FOLLOWING: 196/2023-12-05 07:59:13/CONTROL /PATIENT GROUP NEONATAL 197/2023-12-05 07:59:13/START /ON 198/2023-12-05 07:59:13/CONTROL /TI MAX => 1.00 S 199/2023-12-05 07:59:13/CONTROL /ETS => 25 % 200/2023-12-05 07:59:13/CONTROL /P-RAMP => 50 MS 201/2023-12-05 07:59:13/CONTROL /OXYGEN => 21 % 202/2023-12-05 07:59:13/CONTROL /FLOW TRIGGER => 0.5 L/MIN 203/2023-12-05 07:59:13/CONTROL /PEEP => 6.0 CMH2O 204/2023-12-05 07:59:13/CONTROL /PINSP => 14.0 CMH2O 205/2023-12-05 07:59:13/CONTROL /TI => 0.35 S 206/2023-12-05 07:59:13/CONTROL /RATE => 40 B/MIN 207/2023-12-05 07:59:13/CONFIG /VT/KG => 5 ML/KG 208/2023-12-05 07:59:13/ALARM /FTOTAL (LOW) => 7 B/MIN 209/2023-12-05 07:59:13/ALARM /FTOTAL (HIGH) => 133 B/MIN 210/2023-12-05 07:59:13/ALARM /PLIMIT => 20 CMH2O 211/2023-12-05 07:59:13/ALARM /PRESSURE (LOW) => 5 CMH2O 212/2023-12-05 07:59:13/ALARM /PRESSURE (HIGH) => 30 CMH2O 213/2023-12-05 07:59:13/ALARM /APNEA TIME => 5 S 214/2023-12-05 07:59:13/SPECIAL /VENTILATION TIME => 367 MIN 215/2023-12-05 07:59:13/CONTROL /WEIGHT => 0.75 KG 216/2023-12-05 07:59:13/MODE /STANDBY => NCPAP-PS --[18.12.2023 20:39] - DISCONNECT ALARM NIV MODE C6 INVESTIGATION ARE ONGOIN.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2052821 HAMILTON MEDICAL AG HAMILTON-C6 VENTILATOR CBK HAMILTON MEDICAL AG HAMILTON-C6 07630002808590

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown