FDA Adverse Event Malfunction Summary report: N

TRUFILL DCS ORBIT MINI COMPLEX FILL

MDR report key: 1834031 · Received September 14, 2010

Report

Report Number
1058196-2010-00267
Event Type
Malfunction
Date Received
September 14, 2010
Date of Event
October 30, 2010
Report Date
August 18, 2010
Manufacturer
CORDIS NEUROVASCULAR, INC.
Product Code
HCG
PMA / PMN Number
K053197
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NL
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

IT WAS REPORTED IN AMERICAN JOURNAL OF NEURORADIOLOGY 26: 1342-1348, JULY/JULY 2005 "THREE-DIMENSIONAL PACKING FOR COMPLEX ORBIT COILS FOR THE ENDOVASCULAR TREATMENT OF INTRACRANIAL ANEURYSM", LUBICZ ET AL THAT A (B)(6) FEMALE (PATIENT 9) PRESENTED INCIDENTALLY AND A 4MM ANEURYSM WAS FOUND AT THE (MCA) MIDDLE CEREBRAL ARTERY BIFURCATION. A 4MM/3CM COMPLEX ORBIT COIL WAS PLACED WITHIN THE ANEURISMAL SAC AND DID NOT ADAPT A 3D CONFIGURATION. IT BEHAVED LIKE A HELICAL COIL RATHER THAN A COMPLEX COIL AND DID NOT BRIDGE THE ANEURYSM NECK. BECAUSE OF THE NONOPTIMAL BASKET, THE COIL WAS NOT DETACHED AND WAS RETRIEVED. A 4MM/4CM 3D GDC, GUGLIELMI DETACHABLE COIL, WAS THEN DELIVERED ALLOWING BRIDGING OF THE ANEURYSM NECK. A NONCORDIS EXCELSIOR 10 MICROCATHETER WAS USED FOR COIL PLACEMENT. IT WAS INDICATED THAT THE IMMEDIATE CLINICAL OUTCOME WAS EXCELLENT. SYSTEMIC HEPARINIZATION WAS ADMINISTERED DURING THE PROCEDURE WITH MONITORING OF ADEQUACY OF ANTICOAGULATION BY FREQUENT MEASUREMENTS OF THE ACTIVATED CLOTTING TIME (ACT). A BASELINE ACT WAS OBTAINED BEFORE THE BOLUS INFUSION OF HEPARIN (50-75 IU/KG BODY WEIGHT), AND HOURLY THEREAFTER. THE BOLUS INFUSION OF HEPARIN WAS FOLLOWED BY A CONTINUOUS DRIP (1,000 - 1,500 IU/H), WITH THE PURPOSE OF DOUBLING THE BASELINE ACT. THERE IS NO FURTHER PROCEDURAL OR FOLLOW-UP INFORMATION AVAILABLE. THE DEVICE IS NOT AVAILABLE FOR ANALYSIS AND THE LOT NUMBER IS NOT KNOWN; THEREFORE A DEVICE HISTORY RECORD REVIEW CANNOT BE COMPLETED. IT IS POSSIBLE THAT PROCEDURAL FACTORS, ANEURYSM CHARACTERISTICS AND SIZE VERSUS THE COIL SIZE CONTRIBUTED TO THE EVENT. HOWEVER, BASED ON THE AVAILABLE INFORMATION NO CONCLUSION CAN BE MADE REGARDING THE REPORT EVENT.

Additional Manufacturer Narrative · 1

IN ALL PATIENTS, THE ENDOVASCULAR TREATMENT WAS PERFORMED UNDER GENERAL ANESTHESIA AND SYSTEMIC HEPARINIZATION. THE ADEQUACY OF SYSTEMIC ANTICOAGULATION WAS MONITORED BY FREQUENT MEASUREMENTS OF THE ACTIVATED CLOTTING TIME (ACT). A BASELINE ACT WAS OBTAINED BEFORE THE BOLUS INFUSION OF HEPARIN (50-75 IU/KG BODY WEIGHT), AND HOURLY THEREAFTER. THE BOLUS INFUSION OF HEPARIN WAS FOLLOWED BY A CONTINUOUS DRIP (1,000-1,500 IU/H), WITH THE PURPOSE OF DOUBLING THE BASELINE ACT. IN MOST PATIENTS, SYSTEMIC HEPARINIZATION WAS STOPPED AT THE END OF THE PROCEDURE. FOR WIDE-NECK ANEURYSMS OR IN CASES WITH PERIPROCEDURAL COMPLICATIONS, SYSTEMIC HEPARINIZATION WAS PROLONGED FOR 48-72 HOURS. PATIENTS WERE TREATED BY SELECTIVE EMBOLIZATION WITH ORBIT COILS; WE HAVE TRIED TO OBTAIN A 3D PACKING OF THE ANEURYSMS BY FORMING A BASKET WITH A COMPLEX COIL THAT WAS SUBSEQUENTLY FILLED CONCENTRICALLY WITH SMALLER COMPLEX COILS IN AN ONION-LIKE FASHION. AN EXCELSIOR 10 MICROCATHETER (TARGET THERAPEUTICS, FREMONT, CA) WAS USED TO DELIVER COILS WITHIN THE ANEURYSM. AFTER ENDOVASCULAR TREATMENT, PATIENTS WERE TRANSFERRED TO THE INTENSIVE CARE UNIT, AND FLUID BALANCE, NEUROLOGIC STATUS, AND BLOOD PRESSURE WERE CAREFULLY MONITORED. FOLLOW-UP MRA AT 6 MONTHS WERE OBTAINED IN ALL 16 PATIENTS AND SHOWED 14 COMPLETE OCCLUSIONS, ONE NECK REMNANT, AND ONLY ONE SLIGHT RECANALIZATION. ADDITIONAL INFORMATION WILL BE SUBMITTED WITHIN 30 DAYS UPON RECEIPT.

Description of Event or Problem · 1

LUBICZ ET AL IN AM J NEURADIOL 26: 1342-1348 REPORT IN "THREE-DIMENSIONAL PACKING FOR COMPLEX ORBIT COILS FOR THE ENDOVASCULAR TREATMENT OF INTRACRANIAL ANEURYSM" INDICATED THAT 9 PATIENT PRESENTED INCIDENTALLY AND A 4MM ANEURYSM WAS FOUND AT THE (MCA) MIDDLE CEREBRAL ARTERY BIFURCATION. A 4MM/3CM COMPLEX COIL WAS PLACED WITHIN THE ANEURYSMAL SAC DID NOT ADAPT A 3D CONFIGURATION. BECAUSE OF THE NONOPTIMAL BASKET, THE COIL WAS NOT DETACHED AND WAS RETRIEVED. A 4MM/4CM 3D GDC , GUGLIELMI DETACHABLE COIL, WAS THEN DELIVERED ALLOWING TO BRIDGE THE ANEURYSM NECK.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 TRUFILL DCS ORBIT MINI COMPLEX FILL CNV DCS ORBIT (HCG) HCG CORDIS NEUROVASCULAR, INC. UNK

Patients

Seq Age Sex Outcome Treatment
1 50 YR EXCELSIOR 10 MICROCATHETER