INFUSE BONE GRAFT
Report
- Report Number
- 1030489-2010-01133
- Event Type
- Injury
- Date Received
- September 7, 2010
- Date of Event
- April 5, 2006
- Report Date
- August 18, 2010
- Manufacturer
- MEDTRONIC SOFAMOR DANEK USA, INC.
- Product Code
- MPW
- PMA / PMN Number
- P000058
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- OTHER
Narratives
(B)(4). LITERATURE CITATION: PERRI, ET AL. ADVERSE SWELLING ASSOCIATED WITH THE USE OF RH-BMP-2 IN ANTERIOR CERVICAL DISCECTOMY AND FUSION: A CASE STUDY. THE SPINE JOURNAL, 2007; 7: 235-239. NEITHER THE DEVICE NOR TEST RESULTS NOR IMAGING FILMS WERE RETURNED TO THE MANUFACTURER FOR EVAL. A REVIEW OF THE DEVICE HISTORY RECORDS IS NOT POSSIBLE WITHOUT ADDITIONAL DEVICE INFO. THEREFORE, WE ARE UNABLE TO DETERMINE THE CAUSE OF THE EVENT.
IT IS REPORTED THE PT PRESENTED TO THE EMERGENCY ROOM IN MODERATE DISTRESS WITH NECK ANTERIOR NECK SWELLING AND DIFFICULTY SWALLOWING. THE PT WAS 5 DAYS STATUS-POST ANTERIOR CERVICAL DISCECTOMY AND FUSION (ACDF) AT C3-C4 AND C4-C5 WITH FIXATION AT C3 TO C5, AUGMENTED BY RH-BMP-2/ACS PLACED INSIDE BIOABSORBABLE INTERBODY GRAFTS. IT IS NOTED THAT A RIGID CERVICAL COLLAR WAS WORN CONTINUOUSLY FOR THE FIVE DAYS POST SURGERY. THERE WAS NO WOUND DEHISCENCE OR ERYTHEMA. MASSIVE NECK SWELLING AND SMALL FLUID COLLECTION WAS EVIDENT IPSILATERAL TO THE SIDE OF THE SURGICAL APPROACH. RADIOGRAPHS AND COMPUTED TOMOGRAPHIC SCAN SHOWED SEVERAL POCKETS OF AIR WITHIN THE SOFT TISSUES. A DISCRETE HEMATOMA WAS NOT PRESENT. THERE WERE NO SIGNS OF CERVICAL HARDWARE FAILURE. THE INTERBODY GRAFTS WERE INTACT WITHOUT SIGNS OF FRACTURE OR DISPLACEMENT. THE PT WAS ADMITTED TO THE INTENSIVE CARE UNIT WHERE PARENTERAL STEROIDS WERE ADMINISTERED FOR 24 HOURS DURING MONITORED INTUBATION. THE PT WAS EXTUBATED ON THE SECOND HOSPITAL DAY AND DISCHARGED HOME ON THE FOURTH HOSPITAL DAY AFTER SWELLING SUBSIDED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | INFUSE BONE GRAFT | INFUSE BONE GRAFT | MPW | MEDTRONIC SOFAMOR DANEK USA, INC. | NA | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 54 YR | Hospitalization| R | ANTERIOR CERVICAL PLATE |