FDA Adverse Event Injury Summary report: N

MENTOR MEMORYGEL BREAST IMPLANT

MDR report key: 18307780 · Received December 11, 2023

Report

Report Number
1645337-2023-14568
Event Type
Injury
Date Received
December 11, 2023
Date of Event
September 16, 2023
Manufacturer
MENTOR MEDICAL SYSTEM B.V.
Product Code
FTR
PMA / PMN Number
P030053
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

SINCE THE DEVICE HAS NOT BEEN RETURNED FOR ANALYSIS, NO PRODUCT FAILURE ANALYSIS CAN BE CONDUCTED, AND NO DETERMINATION OF POSSIBLE CONTRIBUTING FACTORS CAN BE MADE. AS SUCH, THE INVESTIGATION WILL BE CLOSED. IF THE COMPLAINT DEVICE IS RECEIVED IN THE FUTURE, THE INVESTIGATION WILL BE REOPENED AND CONDUCTED AS APPROPRIATE. SINCE NO LOT NUMBER WAS PROVIDED, NO MANUFACTURING RECORD EVALUATION COULD BE PERFORMED. REASON FOR DEVICE EXPLANT AND/OR REOPERATION: MATERIAL RUPTURE. MENTOR IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH MENTOR HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, MENTOR, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, MENTOR, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF CERTAIN INFORMATION IS UNKNOWN, NOT AVAILABLE OR DOES NOT APPLY, THE SECTION/FIELD OF THE FORM IS LEFT BLANK. MANUFACTURER¿S REFERENCE NUMBER: (B)(4).

Additional Manufacturer Narrative · 0

ON DECEMBER 20, 2023, MENTOR RECEIVED ADDITIONAL INFORMATION INDICATING THAT THE SUSPECT MEDICAL DEVICES' LOT NUMBER WERE: 5865282 AND 5890459. MENTOR BECAME AWARE THAT THESE DEVICES WERE MANUFACTURED BY MENTOR MEDICAL SYSTEMS B.V, LOCATED IN LEIDEN, THE NETHERLANDS, A FOREIGN MANUFACTURER OF MEDICAL DEVICES THAT ARE NOT CLEARED OR APPROVED FOR SALE IN THE US. IT IS A SEPARATE LEGAL ENTITY FROM MENTOR TEXAS. MENTOR IS NOT REQUIRED TO SUBMIT MDR REPORTS FOR EVENTS OCCURRING IN OTHER COUNTRIES FOR A DEVICE THAT IS MANUFACTURED IN A FOREIGN COUNTRY AND THAT IS NOT CLEARED OR APPROVED FOR MARKETING IN THE US. SINCE MENTOR MEDICAL SYSTEMS B.V. DO NOT MARKET ANY DEVICES IN THE US, MANUFACTURE & MARKET ALL THEIR DEVICES OUTSIDE THE US, AND HAVE NEVER HELD FDA APPROVAL NOR CLEARANCE FOR ANY OF THEIR PRODUCTS, THEIR DEVICES DO NOT MEET THE CRITERIA FOR MDR REPORTABILITY. THIS WILL BE THE LAST FOLLOW-UP REPORT FOR THIS EVENT. ON JANUARY 4, 2024, THE MENTOR FAILURE ANALYSIS LAB RECEIVED THE DEVICE FOR EVALUATION. ON JANUARY 10, 2024, THE PRODUCT INVESTIGATION WAS COMPLETED. DEVICE INVESTIGATION SUMMARY: THE PRODUCT WAS RETURNED TO MENTOR FOR EVALUATION. MENTOR CONDUCTED VISUAL INSPECTION OF THE RETURNED DEVICE. VISUAL ANALYSIS OF THE RETURNED SAMPLE REVEALED THAT THE SMOOTH ROUND MOD. PLUS PROFILE 550CC BREAST IMPLANT WAS FOUND TO BE RUPTURED AND RECEIVED IN FOUR PARTS. IN ADDITION, SHELL ABRASION WAS OBSERVED AT THE EDGES OF THE RUPTURE. THE EVALUATION DETERMINED THAT THE POSSIBLE CAUSE OF THE RUPTURE IS CONSISTENT WITH NORMAL WEAR. SHELL ABRASION SUGGESTS IN-VIVO FOLDING OR CREASING OF THE DEVICE. THIS MAY BE THE RESULT OF THE FOLLOWING FACTORS: CONTINUOUS AND SUSTAINED STRESSES TO THE DEVICE SUCH AS TOO SMALL BREAST POCKET AND FOLDING OR WRINKLING OF THE SHELL IN THE BREAST POCKET. IN SOME CASES, THE BREAST IMPLANTS MAY ALSO WEAR OUT OVER TIME. AS PART OF MENTOR¿S QUALITY PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS. NO CORRECTIVE AND PREVENTIVE ACTION (CAPA) IS REQUIRED NOW.

Description of Event or Problem · 0

IT WAS REPORTED THAT A PATIENT UNDERWENT BREAST PROSTHESIS IMPLANTATION SURGERY WITH TWO MENTOR MEMORYGEL BREAST IMPLANTS. POST-OPERATIVELY, THE PATIENT SUFFERED BILATERAL BREAST IMPLANT RUPTURES. AS A RESULT, THE PATIENT UNDERWENT BILATERAL BREAST IMPLANT REMOVAL AND REPLACEMENT SURGERY ON (B)(6), 2023. THE REPLACEMENT DEVICES WERE: (RIGHT) 550CC MENTOR MEMORYGEL BREAST IMPLANT CATALOG: 3505501BC LOT: 9919805 SN: (B)(6), AND (LEFT) 550CC MENTOR MEMORYGEL BREAST IMPLANT CATALOG: 3505501BC LOT: 9919805 SN: (B)(6). THIS MEDWATCH FORM IS FOR THE RIGHT BREAST PROSTHESIS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1110999 MENTOR MEMORYGEL BREAST IMPLANT PROSTHESIS, BREAST, NONINFLATABLE, INTERNAL, SILICONE GEL-FILLED FTR MENTOR MEDICAL SYSTEM B.V. 5865282

Patients

Seq Age Sex Outcome Treatment
1 43 YR Female Required Intervention