FDA Adverse Event Malfunction Summary report: N

RESTORE ULTRA

MDR report key: 1823588 · Received August 27, 2010

Report

Report Number
3004209178-2010-06553
Event Type
Malfunction
Date Received
August 27, 2010
Date of Event
May 5, 2009
Report Date
July 30, 2010
Manufacturer
MDT PUERTO RICO OPERATIONS CO., JUNCOS
Product Code
LGW
PMA / PMN Number
P840001
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NY, US
Reporter Occupation
NOT APPLICABLE

Narratives

Additional Manufacturer Narrative · 1

(B)(4)

Description of Event or Problem · 1

IT WAS REPORTED IN (B)(6)2009, THAT AFTER THE PATIENT CHARGED THE INS RECHARGER TO ONE-HUNDRED PERCENT, THE DEVICE STILL SHOWED THAT IT NEEDED TO BE CHARGED. THE PATIENT RECEIVED A REPLACEMENT RECHARGER THE FOLLOWING DAY FROM THE MANUFACTURER. IT WAS LATER REPORTED THAT THE PATIENT EXPERIENCED A LOSS OF THERAPEUTIC EFFECT, FOLLOWING IMPLANTATION. THE PATIENT EXPERIENCED PAIN RELIEF FOR ONLY A FEW DAYS, AFTER EVERY PROGRAMMING SESSION. THE PATIENT FELT PAIN IN THE HIP BONE AND DOWN THE LEG. IT WAS NOT STATED WHAT SIDE HIP AND LEG WERE INVOLVED. THERE WAS NO KNOWN RELATED INCIDENT OR ACCIDENT REPORTED. THE PATIENT WAS SCHEDULED FOR REPROGRAMMING. IT WAS LATER REPORTED THAT THE PATIENT EXPERIENCED A SURGING SENSATION, WHEN THE STIMULATION WAS TURNED ON. THE PATIENT (FELT A SHOCKING OR JOLTING SENSATION. THE PATIENT STATED THAT THE PROGRAMMER WORKED BETTER WHEN NOT IN THE PATIENT'S APARTMENT BUILDING. THE PATIENT SUGGESTED THAT ENVIRONMENTAL (HOME) INTERFERENCE AFFECTED THE PATIENT PROGRAMMER. THE PATIENT FURTHER REPORTED THAT THE ANTENNA DID NOT STAY PLUGGED INTO THE ANTENNA JACK. IT WAS NOTED THAT THE PATIENT WAS REPROGRAMMED ON TWO OCCASIONS AND HAD ADEQUATE STIMULATION FOR THE PAIN. NO FURTHER DETAILS, PATIENT SYMPTOMS OR OUTCOME WERE PROVIDED AT THE TIME OF THIS REPORT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 RESTORE ULTRA LGW MDT PUERTO RICO OPERATIONS CO., JUNCOS 37712 NA

Patients

Seq Age Sex Outcome Treatment
1 64 YR EXPLANTED:| IMPLANTED:| IMPLANTED:| EXTENSION: MODEL 7489, LOT # NHU052762V| IMPLANTED:| PROGRAMMER: MODEL 37743, LOT # NKE122506N| EXPLANTED:| EXPLANTED:| IMPLANTED:| IMPLANTED:| ACCESSORY: MODEL 37752, LOT # NKA113816N| LEAD: MODEL 3487A, LOT # J0424776V| EXTENSION: MODEL 7489, LOT # NHU052761V| EXPLANTED:| EXPLANTED:| IMPLANTED:| ACCESSORY: MODEL 37752, LOT # NKA126651N| IMPLANTED:| PROGRAMMER: MODEL 7435, LOT # NFT041334P| EXPLANTED:| LEAD: MODEL 3487A, LOT # J0424776V| IMPLANTED:| EXPLANTED:| EXPLANTED: