HAMILTON-G5
Report
- Report Number
- 3001421318-2023-11837
- Event Type
- Malfunction
- Date Received
- November 14, 2023
- Date of Event
- August 9, 2022
- Report Date
- August 30, 2024
- Manufacturer
- HAMILTON MEDICAL AG
- Product Code
- CBK
- PMA / PMN Number
- K193228
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IS
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
THE COMPLAINT HAS BEEN REOPENED AND REVIEWED ACCORDING TO FDA FORM 483 INSPECTIONAL OBSERVATION EMS #2, EOBS2 FROM THE FDA INSPECTION CONDUCTED BETWEEN JULY 17 TO JULY 21, 2022 AT THE EMS AND BONADUZ SITES. A DETAILED INVESTIGATION WAS PERFORMED BY AN EXPERT FROM THE TECHNICAL SERVICE: NO FURTHER INVESTIGATION OR CORRECTION WILL BE PERFORMED EXCEPT THOSE MENTIONED ABOVE. IN FUTURE HAMILTON MEDICAL AG WILL REPORT AN EVENT SIMILAR TO THIS ISSUE AS IT WILL BE DEEMED A REPORTABLE EVENT. THE ALLEGATION IN THIS COMPLAINT WAS CONFIRMED TO BE A COMPLAINT. WITH THIS INVESTIGATION IT HAS BEEN CONFIRMED THAT THE DEVICE FAILED TO MEET ITS SPECIFICATIONS AT THE TIME OF THE EVENT WHILE THE VENTILATOR WAS USED. THE ROOT CAUSE WAS DETERMINED TO BE A DEFECTIVE SERVO MODULE (INSPIRATORY VALVE). IN CONSEQUENCE (CORRECTION) MSP HAMILTON-G5 INSPIRATION VALVE WITH PART NUMBER 10082605 WAS REPLACED. THERE WAS NO PATIENT OR USER HARM.
THE COMPLAINT HAS BEEN REOPENED AND REVIEWED ACCORDING TO FDA FORM 483 INSPECTIONAL OBSERVATION EMS #2, EOBS2 FROM THE FDA INSPECTION CONDUCTED BETWEEN JULY 17 TO JULY 21, 2022 AT THE EMS AND BONADUZ SITES. A DETAILED INVESTIGATION WAS PERFORMED BY AN EXPERT FROM THE TECHNICAL SERVICE: NO FURTHER INVESTIGATION OR CORRECTION WILL BE PERFORMED EXCEPT THOSE MENTIONED ABOVE. IN FUTURE HAMILTON MEDICAL AG WILL REPORT AN EVENT SIMILAR TO THIS ISSUE AS IT WILL BE DEEMED A REPORTABLE EVENT. THE ALLEGATION IN THIS COMPLAINT WAS CONFIRMED TO BE A COMPLAINT. WITH THIS INVESTIGATION IT HAS BEEN CONFIRMED THAT THE DEVICE FAILED TO MEET ITS SPECIFICATIONS AT THE TIME OF THE EVENT WHILE THE VENTILATOR WAS USED. THE ROOT CAUSE WAS DETERMINED TO BE A DEFECTIVE SERVO MODULE (INSPIRATORY VALVE). IN CONSEQUENCE (CORRECTION) MSP HAMILTON-G5 INSPIRATION VALVE WITH PART NUMBER 10082605 WAS REPLACED. THERE WAS NO PATIENT OR USER HARM. HAMILTON MEDICAL AG COMPLAINT NUMBER: (B)(4). FOLLOW-UP 1 - CORRECTED INFORMATION: **UDI RELATED DATA QUALITY UPDATES ONLY** FIELD D4 WAS UPDATED WITH FULL UDI INFORMATION AS REQUESTED. UPDATED FIELDS: B4, D1, D3, D4, G1, G3, G6, H2, H4.
DEAR MILAD, A CUSTOMER HAS A PROBLEM WITH A G5 UNIT: WHEN HE TURNED IT ON, THE UNITS BEEPS ALTERNATELY, DID A SELF TEST AND SHOWED TF: 9907, 2414, 5509. PLEASE ADVISE, MEIR SC2201544 PLEASE ADVISE. B.R. ILAN OFMAN BEPEX LTD.
DEAR MILAD, A CUSTOMER HAS A PROBLEM WITH A G5 UNIT: WHEN HE TURNED IT ON, THE UNITS BEEPS ALTERNATELY, DID A SELF TEST AND SHOWED TF: 9907, 2414, 5509. PLEASE ADVISE, MEIR SC2201544 PLEASE ADVISE. B.R. ILAN OFMAN BEPEX LTD.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1927212 | HAMILTON-G5 | HAMILTON-G5 | CBK | HAMILTON MEDICAL AG | 159001 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |