BD ALARIS PUMP MODULE SMARTSITE INFUSION SET
Report
- Report Number
- 9616066-2023-02165
- Event Type
- Malfunction
- Date Received
- November 7, 2023
- Date of Event
- September 23, 2023
- Report Date
- October 24, 2023
- Manufacturer
- SISTEMAS MEDICOS ALARIS S.A. DE C.V.
- Product Code
- FPA
- UDI-DI
- 50885403232303
- PMA / PMN Number
- K944320
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
H3. A DEVICE EVALUATION IS ANTICIPATED BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.
IT WAS REPORTED THAT BD ALARIS PUMP MODULE SMARTSITE INFUSION SET HAD AIR IN THE LINE, THE FOLLOWING INFORMATION WAS RECEIVED BY THE INITIAL REPORTER WITH THE VERBATIM: THANK SO MUCH FOR TAKING THE TIME TO TALK TO ME TODAY. AS PER OUR CONVERSATION: YOU HAVE A GENERALIZED COMPLAINT OF AIR-IN-LINE WITH THE IV SET 11522558 WHICH IS THE BD BALL/VALVE SET . THERE HAVE BEEN MULTIPLE INTERNAL REPORTS (UNKNOWN NUMBER OF EVENTS) OF THE BALL FAILING TO SEAT PROPERLY AND AIR GETTING DOWN INTO THE LINE. THERE IS NOT A LOT NUMBER AVAILABLE FOR THESE EVENTS AND THERE WAS NO PATIENT HARM RELATED TO THE AIR IN LINE. AN UNKNOWN NUMBER OF THESE EVENTS HAVE HAPPENED IN AN OUTPATIENT INFUSION CENTER. PLEASE CONFIRM THAT THIS INFORMATION REGARDING THE REPORTED ISSUE OF AIR IN LINE FROM BALL VALVE NOT SEATING PROPERLY IS ACCURATE AND THAT THERE IS NOT ANY OTHER INFORMATION AVAILABLE. ON PREVIOUS SITE VISITS, CPC DETERMINED THAT THE PRACTICE IN THE INFUSION CENTER OF OVER PROGRAMMING THE VTBI (VOLUME TO BE INFUSED) TO INCLUDE THE FLUSH WAS A CONTRIBUTING FACTOR TO THE FAILURE OF THE BALL SEATING PROPERLY. A VACUUM IS CREATED WHICH CAN POTENTIALLY PREVENT THE BALL FROM COMPLETELY SEALING THE VALVE. IF THERE IS A DEFORMITY IN THE DRIP CHAMBER THIS CAN ALSO LEAD TO THE BALL NOT SEATING PROPERLY. A POSSIBLE SOLUTION WOULD BE TO CHANGE TO THE SHORT SET CONNECTED TO A 3 PORT LONG PRIMARY SET TO DELIVER THE MEDICATIONS. THEY COULD INCLUDE THE FLUSH AS THEY LIKE TO, AND THEY WOULD INTENTIONALLY RUN THE MEDICATION TO THE AIR IN LINE SENSOR. THE PRIMARY LINE WOULD THEN BE USED TO FLUSH THE REST OF THE MEDICATION. I AM INCLUDING A LINK TO A VIDEO THAT SHOWS HOW THIS WORKS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 812851 | BD ALARIS PUMP MODULE SMARTSITE INFUSION SET | INTRAVASCULAR ADMINISTRATION SET | FPA | SISTEMAS MEDICOS ALARIS S.A. DE C.V. | UNKNOWN | 50885403232303 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |