LOGIC CR TIB INSERT STD, SZ 5, 9MM
Report
- Report Number
- 1038671-2023-02638
- Event Type
- Injury
- Date Received
- October 31, 2023
- Date of Event
- November 1, 2021
- Report Date
- October 31, 2024
- Manufacturer
- EXACTECH, INC.
- Product Code
- JWH
- UDI-DI
- 10885862174543
- PMA / PMN Number
- K111400
- Removal / Correction Number
- Z-0021-2022
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FL, US
- Reporter Occupation
- 003
Narratives
D10: CONCOMITANTS: 02-010-03-0350 - LOGIC CR FEMORAL CEM, RIGHT, SZ 5, (B)(6). 02-012-45-5050 - LGC TIBIAL FIT TRAY CEM SZ 5F / 5T, (B)(6). 200-02-38 - THREE PEG PATELLA 38MM, (B)(6). 201-78-89 - 3" DRILL BIT, MOD. HEX 2 PACK, (B)(6). 02-010-03-0350 - LOGIC CR FEMORAL CEM, RIGHT, SZ 5, (B)(6). 02-012-45-5050 - LGC TIBIAL FIT TRAY CEM SZ 5F / 5T, (B)(6). 02-012-47-5009 - LOGIC CR TIB INSERT STD, SZ 5, 9MM, (B)(6). 200-02-38 - THREE PEG PATELLA 38MM, (B)(6). 201-78-89 - 3" DRILL BIT, MOD. HEX 2 PACK, (B)(6). PENDING INVESTIGATION.
H6: CORRECTED THE FOLLOWING: HEALTH EFFECT - CLINICAL CODE, MEDICAL DEVICE PROBLEM CODE, COMPONENT CODE, TYPE OF INVESTIGATION, INVESTIGATION FINDINGS, INVESTIGATION CONCLUSIONS MANUFACTURER NARRATIVE UPDATED: THE REASON FOR THE REVISION REPORTED CANNOT BE CONFIRMED FROM THE INFORMATION PROVIDED BUT MAY BE THE RESULT OF PROSTHESIS WEAR OR DUE TO INCLUSION OF THE POLYETHYLENE IN THE PACKAGING RECALL. POTENTIAL CONTRIBUTIONS OF USER AND PATIENT-RELATED CONSIDERATIONS TO THE EVENT COULD NOT BE ASSESSED AS THE DEVICES WERE NOT AVAILABLE FOR EVALUATION AND IMAGES, RADIOGRAPHS, AND RELEVANT CLINICAL INFORMATION WERE NOT PROVIDED.
AS REPORTED VIA LEGAL DOCUMENTATION THE PATIENT HAD A RIGHT KNEE REPLACEMENT ON (B)(6) 2016. APPROXIMATELY 4 YEARS AND 11 MONTHS AFTER THE INITIAL PROCEDURE THE PATIENT HAD A RIGHT KNEE REVISION ON (B)(6) 2021. THERE IS NO OTHER PATIENT DEMOGRAPHIC OR MEDICAL HISTORY AVAILABLE. THERE IS NO INFORMATION ON THE SURGICAL PROCEDURE OR PATIENT OUTCOME. THERE IS NO DEVICE RETURN. THERE ARE NO PHOTOS OR OTHER IMAGES OF THE DEVICE PROVIDED. NO ADDITIONAL INFORMATION IS AVAILABLE. THE PATIENT HAS FILED A SHORT-FORM COMPLAINT IN A MULTIDISTRICT LITIGATION TITLED IN RE: EXACTECH POLYETHYLENE ORTHOPEDIC PRODUCTS LIABILITY LITIGATION, MDL NO. 3044 (NGG) (MMH), AND PENDING IN THE EASTERN DISTRICT OF NEW YORK. PER THE TRANSFER ORDER CREATING THIS MULTIDISTRICT LITIGATION, ¿PLAINTIFFS¿ALLEGE THAT THEIR KNEE OR HIP REPLACEMENT DEVICES¿FAILED PREMATURELY BECAUSE OF DEGRADATION OF THE DEVICE¿S POLYETHYLENE COMPONENT, WHICH RESULTED IN THE PREMATURE REMOVAL (OR PLANNED REMOVAL) OF THE PROSTHESIS AT ISSUE.¿ BECAUSE THE PATIENT HAS FILED A SUIT IN THIS MULTIDISTRICT LITIGATION, THE PATIENT APPEARS TO ALLEGE THAT THE PATIENT WAS INJURED AS A RESULT OF PREMATURE WEAR OF AN EXACTECH POLYETHYLENE DEVICE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1958614 | LOGIC CR TIB INSERT STD, SZ 5, 9MM | PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL | JWH | EXACTECH, INC. | UNK | 10885862174543 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | Required Intervention | SEE H10 |