PERSONAL CYCLER MACHINE 100 VOLTS
Report
- Report Number
- 1423500-2010-02540
- Event Type
- Death
- Date Received
- August 16, 2010
- Date of Event
- July 10, 2010
- Report Date
- July 10, 2010
- Manufacturer
- BAXTER HEALTHCARE - SINGAPORE
- Product Code
- FKX
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4). DEVICE HAS NOT BE RETURNED TO BAXTER AT TIME THIS MDR WAS CREATED. FOLLOW UP INFORMATION WILL BE SENT IF IT BECOMES AVAILABLE.A 510K NUMBER WILL NOT BE INCLUDED IN THIS MDR. A 510K HAS NOT BEEN ISSUED FOR THIS PRODUCT AS IT IS ONLY DISTRIBUTED OUT SIDE THE UNITED STATES.
THIS IS A SPONTANEOUS CONSUMER REPORT BY A PATIENT'S FAMILY FROM (B)(6) OF DEATH IN A FEMALE PATIENT COINCIDENT WITH DIANEAL-N PD-2 2.5% AND EXTRANEAL THERAPIES. ON AN UNKNOWN DATE, THE PATIENT BEGAN DIANEAL-N PD-2 2.5% AND EXTRANEAL THERAPIES. ON (B)(6)2010, THE PATIENT'S FAMILY CONTACTED BAXTER (B)(4) TECHNICAL SERVICE CENTER AND STATED THAT THE PATIENT HAD DIED ON THAT DAY. CAUSE OF DEATH AND CAUSALITY WERE NOT PROVIDED. FOLLOW-UP INFORMATION WAS OBTAINED BY THE PHYSICIAN. ON AN UNKNOWN DATE IN (B)(6)2010, THE PATIENT DEVELOPED PERITONITIS. ON (B)(6)2010, SHE DIED OF CARDIAC FAILURE. AT THE TIME OF HER DEATH, THE PERITONITIS WAS RESOLVING. PERITONEAL DIALYSIS (PD) THERAPY WAS ONGOING UNTIL HER DEATH. THE PHYSICIAN COULD NOT DENY THE POSSIBILITY THAT PERITONITIS, HAD NOT WORSENED THE CARDIAC FAILURE OR HAD HASTENED THE PATIENT?S DEATH. THE PHYSICIAN CONSIDERED PERITONITIS AS NON-SERIOUS. FOLLOW-UP INFORMATION WAS RECEIVED AND THE CAUSE OF DEATH WAS AMENDED FROM CARDIAC FAILURE TO PERITONITIS BACTERIAL. THE PATIENT HAD BEEN HOSPITALIZED FOR AN UNKNOWN REASON. ON (B)(6)2010, SHE DEVELOPED PERITONITIS BACTERIAL. UNSPECIFIED ANTIBIOTIC WERE ADMINISTERED FOR THE EVENT. ON AN UNKNOWN DATE, THE EVENT WAS RESOLVED. ON (B)(6)2010, SHE DEVELOPED PERITONITIS BACTERIAL. AN UNSPECIFIED ANTIBIOTIC WAS ADMINISTERED FOR THE EVENT. ON (B)(6)2010, SHE DIED OF THE EVENT. PD THERAPY WAS ONGOING UNTIL HER DEATH. THE PHYSICIAN BELIEVED THAT THE EVENT WAS POSSIBLY RELATED TO PD THERAPY. AS THE PERITONITIS WAS BACTERIAL, THE PHYSICIAN CONSIDERED THE EVENT WAS NOT RELATED TO PD SOLUTION DIRECTLY. BUT, THE PHYSICIAN COULD NOT DENY THE POSSIBILITY OF CONTAMINATION WHEN PD SOLUTION WAS ADMINISTERED. THIS MDR IS FOR THE PATIENT'S DEATH AN ADDITIONAL MDR WILL BE SENT TO REPORT THE PERITONITIS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | PERSONAL CYCLER MACHINE 100 VOLTS | SYSTEM, PERITONEAL, AUTOMATIC DELIVERY | FKX | BAXTER HEALTHCARE - SINGAPORE |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Death |