SURGICEL ABSORBABLE HEMOSTAT UNKNOWN
Report
- Report Number
- 2210968-2023-08109
- Event Type
- Injury
- Date Received
- October 23, 2023
- Date of Event
- July 31, 2023
- Report Date
- October 23, 2023
- Manufacturer
- ETHICON INC.
- Product Code
- LMG
- PMA / PMN Number
- N12159
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KS
- Reporter Occupation
- OTHER
Narratives
PRODUCT COMPLAINT # (B)(4). H6. COMPONENT CODE: G07002 - DEVICE NOT RETURNED. THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORD EVALUATION CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. 1. WERE THE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IF YES, PLEASE PROVIDE A COMPLAINT REFERENCE NUMBER(S). 2. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCTS INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE PATIENT CONSEQUENCES DESCRIBED IN THE ARTICLE? 3. DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCTS USED IN THIS PROCEDURE? 4. WAS THERE ANY MEDICAL OR SURGICAL INTERVENTION PERFORMED (PRODUCT REMOVED; RE-OPERATION; RE-CLOSURE; PRESCRIPTION STEROIDS; ANTIBIOTICS PRESCRIBED)? IF SO, PLEASE CLARIFY. 5. CAN SPECIFIC PATIENT DEMOGRAPHICS: INITIALS; AGE OR DATE OF BIRTH; BMI; GENDER; PATIENT PRE-EXISTING MEDICAL CONDITIONS (I.E. ALLERGIES, HISTORY OF REACTIONS), ALL CONCOMITANT MEDICATIONS, PAST MEDICAL HISTORY, ANY TREATMENT REQUIRED FOR EVENTS, DOSE, FREQUENCY, AND THERAPY DATES OF STUDY DRUGS BE PROVIDED? CITATION: LAND SURG 2023;12(7):905-916 / HTTPS://DX.DOI.ORG/10.21037/GS-22-675. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE.
IT WAS REPORTED VIA A JOURNAL ARTICLE: TITLE: THE NOVEL USE AND FEASIBILITY OF HEMOSTATIC OXIDIZED REGENERATED CELLULOSE AGENT (SURGIGUARD® ): MULTICENTER RETROSPECTIVE STUDY. AUTHORS: SEOUNG YOON RHO1, MIRYUNG JIN, HYUN KOO KIM, JEONG-IK PARK, JONG-HWA PARK, SANGCHUL YUN, MARIA LEE, SAE BYEOL CHOI, JAE-YOUNG HONG, KYUNG SIK KIM. CITATION: GLAND SURG 2023;12(7):905-916 / HTTPS://DX.DOI.ORG/10.21037/GS-22-675. THE OBJECTIVE OF THIS STUDY IS TO CONFIRM THAT THE USE OF SURGIGUARD® ALONE IS EFFECTIVE, SAFE AND FEASIBLE COMPARED TO COMBINATION WITH OTHER HEMOSTATIC METHODS. BETWEEN JANUARY 2018 AND DECEMBER 2018, A TOTAL OF 807 PATIENTS WERE ENROLLED; 447 PATIENTS HAD COMORBIDITIES. NINE PATIENTS REPORTED ADVERSE EFFECTS, SUCH AS ABSCESS, BLEEDING, OR LEG SWELLING, BUT WE FOUND NO DIRECT CORRELATION WITH SURGIGUARD®. DUE TO BIOCOMPATIBILITY, BIODEGRADABILITY, LOW TOXICITY, AND RELATIVELY LOW COST, ORC HAS BEEN WIDELY USED IN MEDICAL PRODUCTS, SUCH AS HEMOSTATIC AGENTS, WOUND DRESSINGS, AND DRUG CARRIERS. IN THE 1960S, SURGICEL® (JOHNSON AND JOHNSON, NEW BRUNSWICK, NJ, USA) WAS INTRODUCED TO THE CLINICAL MARKET AS THE FIRST ORC-DERIVED HEMOSTATIC AGENT. SINCE THEN, ORC HAS EVOLVED INTO A GLOBALLY USED TOPICAL HEMOSTATIC AGENTS. REPORTED COMPLICATIONS INCLUDED BLEEDING/LEAKAGE FROM TREATED SITE (N=?), POSTOPERATIVE INTESTINAL OBSTRUCTION (N=?), ABSCESS (N=?), FEVER (N=?), LEG SWELLING (N=?), RESPIRATORY DYSFUNCTION (N=?). IN CONCLUSION, SURGIGUARD® EXHIBITED GREATER EFFECTIVENESS WHEN USED ALONE. NO DIRECT ADVERSE EFFECTS ASSOCIATED WITH SURGIGUARD® USE WERE REPORTED, AND SURGIGUARD® HAD STABLE FEASIBILITY. PROSPECTIVE COMPARATIVE STUDIES ARE NEEDED IN THE FUTURE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2069931 | SURGICEL ABSORBABLE HEMOSTAT UNKNOWN | AGENT, ABSORBABLE HEMOSTATIC, NON-COLLAGEN BASED | LMG | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown | Required Intervention |