FDA Adverse Event Injury Summary report: N

OT ULTRASMART METER

MDR report key: 1794860 · Received August 11, 2010

Report

Report Number
2939301-2010-06468
Event Type
Injury
Date Received
August 11, 2010
Date of Event
July 18, 2010
Report Date
July 21, 2010
Manufacturer
LIFESCAN, INC.
Product Code
NBW
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THE LAY USER/PATIENT'S METER HAS BEEN RETURNED AND EVALUATED BY LIFESCAN PRODUCT ANALYSIS WITH THE FOLLOWING FINDINGS: THE METER INVOLVED IN THIS CASE HAS PASSED TESTING WITH NO FAULTS FOUND. IF ANY ADDITIONAL INFORMATION IS AVAILABLE, THE FDA WILL BE NOTIFIED IN A SECOND FOLLOW UP REPORT. AT THIS TIME, WE CONSIDER THIS MATTER CLOSED.

Additional Manufacturer Narrative · 1

LIFESCAN (LFS) HAS REQUESTED RETURN OF THE SUBJECT PRODUCT(S) FOR EVALUATION. IF THE PRODUCT(S) ARE RETURNED, LFS WILL EVALUATE IT/THEM AND INFORM FDA OF PRODUCT(S) THAT DO NOT PASS INSPECTION IN A SUPPLEMENTAL REPORT.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE HANDPIECE WAS OVERHEATING PRIOR TO THE START OF A SURGICAL PROCEDURE. THE DEVICE WAS NOT USED IN A PROCEDURE, SO THERE WAS NO PATIENT INVOLVEMENT. THERE WERE NO ADVERSE CONSEQUENCES REPORTED AT A RESULT OF THIS EVENT.

Description of Event or Problem · 1

ON (B)(6) 2010, THE LAY USER/PATIENT CONTACTED LIFESCAN (LFS) ALLEGING THAT THE ONETOUCH ULTRASMART METER WAS READING INACCURATELY ERRATIC. THE MEDICAL SURVEILLANCE SPECIALIST (MSS) WAS UNABLE TO REACH THE LAY USER/ PATIENT BY PHONE FOR FOLLOW-UP QUESTIONS. THE FOLLOWING COMPLAINT WAS CLASSIFIED BASED ON INFORMATION OBTAINED FROM THE CUSTOMER SERVICE REPRESENTATIVE (CSR). THE PATIENT ALLEGED THAT THE ISSUE BEGAN ON (B)(6) 2010 AT 7 OR 8 PM. ON AN UNSPECIFIED DATE/TIME THE PATIENT REPORTED BLOOD GLUCOSE RESULTS OF "120, 187, AND 190 MG/DL" WITH A LIFESCAN METER, PERFORMED WITHIN 20 MINUTES OF EACH OTHER. BASED ON STATISTICAL METHODOLOGY, THE CALCULATED DIFFERENCE OF THESE GLUCOSE RESULTS EXCEEDS THE EXPECTED VALUE OF <= 20% AND/OR <= 20 MG/DL. THE PATIENT STATED SHE MANAGES HER DIABETES WITH INSULIN (SELF ADJUSTER); HOWEVER, THE PATIENT DENIED TAKING ANY ACTION IN RESPONSE TO THE ALLEGED METER ISSUE. ON AN UNSPECIFIED DATE/TIME AFTER THE ALLEGED ISSUE BEGAN THE PATIENT CLAIMED SHE DEVELOPED A HEADACHE, FELT WEAK, AND WAS SWEATING. THE PATIENT, HOWEVER, DENIED RECEIVING ANY MEDICAL TREATMENT AFTER THE ALLEGED ISSUE BEGAN. AT THE TIME OF TROUBLESHOOTING, THE CSR VERIFIED THE CORRECT UNIT OF MEASUREMENT ON THE SUBJECT METER AND THAT THE BLOOD GLUCOSE RESULTS WERE FROM THE APPROVED (PER OWNER'S BOOKLET) SAMPLE SITE. THE CSR ALSO NOTED THAT THE PATIENT FOLLOWED THE CORRECT BLOOD GLUCOSE TESTING PROCEDURE (PER OWNER'S BOOKLET). REPLACEMENT PRODUCTS WERE SENT TO THE PATIENT. BASED ON THE INFORMATION PROVIDED, THIS COMPLAINT IS BEING REPORTED DUE TO THE FOLLOWING CONCLUSION: THE PATIENT CLAIMED THAT SHE DEVELOPED SYMPTOMS THAT CAN BE ASSOCIATED WITH A SERIOUS INJURY AFTER THE ALLEGED ISSUE BEGAN.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 OT ULTRASMART METER GLUCOSE MONITORING SYS/KIT NBW LIFESCAN, INC. 3007050

Patients

Seq Age Sex Outcome Treatment
1 70 YR Life Threatening