FDA Adverse Event Malfunction Summary report: N

ULTRATHANE DAWSON-MUELLER MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER

MDR report key: 17818795 · Received September 26, 2023

Report

Report Number
1820334-2023-01289
Event Type
Malfunction
Date Received
September 26, 2023
Date of Event
July 3, 2023
Report Date
February 15, 2024
Manufacturer
COOK INC
Product Code
FGE
UDI-DI
00827002097056
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

THIS REPORT INCLUDES INFORMATION KNOWN AT THIS TIME. A FOLLOW-UP REPORT WILL BE SUBMITTED SHOULD ADDITIONAL RELEVANT INFORMATION BECOME AVAILABLE. THIS REPORT IS REQUIRED BY THE FDA UNDER 21 CFR PART 803 AND IS BASED ON UNCONFIRMED INFORMATION SUBMITTED BY OTHERS. NEITHER THE SUBMISSION OF THIS REPORT NOR ANY STATEMENT CONTAINED HEREIN IS INTENDED TO BE AN ADMISSION THAT ANY COOK DEVICE IS DEFECTIVE OR MALFUNCTIONED OR THAT A DEATH OR SERIOUS INJURY OCCURRED; NOR IS IT ADMISSION THAT ANY COOK DEVICE CAUSED, CONTRIBUTED TO, OR IS LIKELY TO CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS INJURY IF A MALFUNCTION OCCURRED.

Additional Manufacturer Narrative · 0

BLANK FIELDS ON THIS FORM INDICATE THE INFORMATION IS UNKNOWN, UNAVAILABLE, OR UNCHANGED. CORRECTION: D2A, D2B, G4 D2A: GBO CATHETER, NEPHROSTOMY, GENERAL & PLASTIC SURGERY; LJE CATHETER, NEPHROSTOMY D2B: GBO, LJE G4: K173035 INVESTIGATION ¿ EVALUATION IT WAS REPORTED THE STIFFENING CANNULA OF A ULTRATHANE DAWSON-MUELLER MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER WAS DIFFICULT TO REMOVE. AFTER PLACING THE DRAINAGE CATHETER, THE STIFFENING CANNULA COULD NOT BE REMOVED. THE CANNULA WAS FORCEFULLY WITHDRAWN RESULTING IN THE PATIENT EXPERIENCING STRONG PAIN. THE PROCEDURE WAS COMPLETED BY USING ANOTHER, LIKE DEVICE. NO OTHER ADVERSE EFFECTS NOR ADDITIONAL PROCEDURES WERE REPORTED FOR THIS INCIDENT. REVIEWS OF DOCUMENTATION INCLUDING THE COMPLAINT HISTORY, DEVICE HISTORY RECORD (DHR), QUALITY CONTROL PROCEDURES, SPECIFICATIONS, MANUFACTURING INSTRUCTIONS (MI), AND INSTRUCTIONS FOR USE (IFU), AS WELL AS A VISUAL INSPECTION, FUNCTIONAL TEST, AND DIMENSIONAL VERIFICATION OF THE RETURNED DEVICE, WERE CONDUCTED DURING THE INVESTIGATION. ONE USED CATHETER AS WELL AS THE SUPPLIED DISPOSABLE STIFFENING CANNULA WAS RETURNED TO COOK FOR EVALUATION. DURING TABLE TOP TESTING, THE STIFFENING CANNULA WAS ABLE TO BE INSERTED AND REMOVED FROM THE CATHETER, ENCOUNTERING SOME RESISTANCE. DIMENSIONAL ANALYSIS CONFIRMED THAT THE DEVICE AND COMPONENTS WERE MANUFACTURED TO THE CORRECT SPECIFICATIONS AND TOLERANCES. UPON VISUAL INSPECTION, THE DEVICE HAD NO VISIBLE EVIDENCE OF SURFACE DEFECTS. ADDITIONALLY, A DOCUMENT-BASED INVESTIGATION EVALUATION WAS PERFORMED. A REVIEW OF THE DEVICE MASTER RECORD (DMR) CONCLUDED THAT SUFFICIENT INSPECTION ACTIVITIES ARE IN PLACE TO IDENTIFY THIS FAILURE MODE PRIOR TO DISTRIBUTION. A REVIEW OF THE DHRS FOR THE REPORTED COMPLAINT DEVICE LOT AND THE RELATED SUBASSEMBLY LOTS REVEALED RELEVANT NON-CONFORMANCES WHICH WERE SCRAPPED PRIOR TO FURTHER PROCESSING OF THE ORDER. ALL REMAINING DEVICES IN THE LOT UNDERWENT 100% VERIFICATION. A DATABASE SEARCH DID NOT IDENTIFY ANY OTHER EVENTS ASSOCIATED WITH THE REPORTED DEVICE LOT. COOK ALSO REVIEWED PRODUCT LABELING. THE PRODUCT IFU, [T_MULTI_REV5] ¿MULTIPURPOSE DRAINAGE CATHETER,¿ PROVIDES THE FOLLOWING INFORMATION TO THE USER RELATED TO THE REPORTED FAILURE MODE: PRECAUTIONS: ¿WHEN INSERTING A STIFFENING CANNULA INTO A CATHETER WITH RETENTION SUTURE, HOLD SUTURE DURING CANNULA INSERTION TO AVOID BUNCHING OR TANGLING OF SUTURE.¿ INSTRUCTIONS FOR USE: ¿UNDER FLUOROSCOPIC CONTROL, PERFORM STANDARD TECHNIQUES FOR PLACEMENT OF PERCUTANEOUS DRAINING CATHETERS, EITHER BY SELDINGER ACCESS OR TROCAR ACCESS. -ONCE CATHETER IS IN DESIRED LOCATION, REMOVE ANY WIRE GUIDES, TROCARS, OR STIFFENERS, ALLOWING THE CATHETER TO FOR ITS CONFIGURATION.¿ HOW SUPPLIED: ¿SUPPLIED STERILIZE BY ETHYLENE OXIDE GAS IN PEEL-OPEN PACKAGES. INTENDED FOR ONE-TIME USE. STERILE IF PACKAGE IS UNOPENED OR UNDAMAGED. DO NOT USE THE PRODUCT IF THERE IS DOUBT AS TO WHETHER THE PRODUCT IS STERILE. STORE IN A DARK, DRY, COOL PLACE. AVOID EXTENDED EXPOSURE TO LIGHT. UPON REMOVAL FROM PACKAGE, INSPECT THE PRODUCT TO ENSURE NO DAMAGE HAS OCCURRED.¿ THE INFORMATION PROVIDED UPON REVIEW OF THE DMR, IFU AND DHR SUGGESTS THAT THE DEVICE WAS NOT MANUFACTURED OUT OF SPECIFICATION, AND THAT THERE ARE NO NONCONFORMING DEVICES IN HOUSE OR OUT IN THE FIELD. BASED ON THE INFORMATION PROVIDED, INSPECTION OF THE RETURNED DEVICE, AND THE RESULTS OF THE INVESTI PER THE RISK ASSESSMENT NO FURTHER ACTION IS REQUIRED. THIS REPORT IS REQUIRED BY THE FDA UNDERGATION, COOK CONCLUDED THE CAUSE OF THIS EVENT CAN BE TRACED TO COMPONENT FAILURE WITHOUT A MANUFACTURING OR DESIGN DEFICIENCY. THE APPROPRIATE PERSONNEL HAVE BEEN NOTIFIED. COOK WILL CONTINUE TO MONITOR FOR SIMILAR COMPLAINTS. 21 CFR PART 803 AND IS BASED ON UNCONFIRMED INFORMATION SUBMITTED BY OTHERS. NEITHER THE SUBMISSION OF THIS REPORT NOR ANY STATEMENT CONTAINED HEREIN IS INTENDED TO BE AN ADMISSION THAT ANY COOK DEVICE IS DEFECTIVE OR MALFUNCTIONED, THAT A DEATH OR SERIOUS INJURY OCCURRED, NOR THAT ANY COOK DEVICE CAUSED, CONTRIBUTED TO, OR IS LIKELY TO CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS INJURY IF A MALFUNCTION OCCURRED.

Additional Manufacturer Narrative · 0

BLANK FIELDS ON THIS FORM INDICATE THE INFORMATION IS UNKNOWN OR UNAVAILABLE. G4 - PMA/510(K) #: EXEMPT. THIS REPORT INCLUDES INFORMATION KNOWN AT THIS TIME. A FOLLOW UP REPORT WILL BE SUBMITTED SHOULD ADDITIONAL RELEVANT INFORMATION BECOME AVAILABLE. THIS REPORT IS REQUIRED BY THE FDA UNDER 21 CFR PART 803. THIS REPORT IS BASED ON UNCONFIRMED INFORMATION SUBMITTED BY OTHERS. NEITHER THE SUBMISSION OF THIS REPORT NOR ANY STATEMENT MADE IN IT IS INTENDED TO BE AN ADMISSION THAT ANY COOK DEVICE IS DEFECTIVE OR MALFUNCTIONED; THAT A DEATH OR SERIOUS INJURY OCCURRED; OR THAT ANY COOK DEVICE CAUSED OR CONTRIBUTED TO; OR IS LIKELY TO CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS INJURY IF A MALFUNCTION OCCURRED.

Description of Event or Problem · 0

NO ADDITIONAL INFORMATION REGARDING PATIENT AND/OR EVENT DETAILS HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.

Description of Event or Problem · 0

NO ADDITIONAL INFORMATION REGARDING THE PATIENT AND/OR EVENT HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.

Description of Event or Problem · 0

IT WAS REPORTED THE STIFFENING CANNULA OF A ULTRATHANE DAWSON-MUELLER MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER WAS DIFFICULT TO REMOVE. AFTER PLACING THE DRAINAGE CATHETER, THE STIFFENING CANNULA COULD NOT BE REMOVED. THE CANNULA WAS FORCEFULLY WITHDRAWN, RESULTING IN THE PATIENT EXPERIENCING STRONG PAIN. THE PROCEDURE WAS COMPLETED BY USING ANOTHER, LIKE DEVICE. NO OTHER ADVERSE EFFECTS NOR ADDITIONAL PROCEDURES WERE REPORTED FOR THIS INCIDENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1677961 ULTRATHANE DAWSON-MUELLER MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER FGE CATHETER, BILIARY, DIAGNOSTIC FGE COOK INC N/A 14573004 00827002097056
776782 ULTRATHANE DAWSON-MUELLER MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER FGE CATHETER, BILIARY, DIAGNOSTIC FGE COOK INC N/A 14573004 00827002097056

Patients

Seq Age Sex Outcome Treatment
1 55 YR Male