UNKNOWN REVOLVE
Report
- Report Number
- 1000306051-2021-00004
- Event Type
- Injury
- Date Received
- September 11, 2023
- Report Date
- September 11, 2023
- Manufacturer
- LIFECELL
- Product Code
- MUU
- PMA / PMN Number
- K120902
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TN, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
NASHVILLE. ¿COMPARISON OF TELFA ROLLING AND A CLOSED WASHING SYSTEM FOR ... : PLASTIC AND RECONSTRUCTIVE SURGERY.¿ LWW, JOURNALS.LWW.COM/PLASRECONSURG/FULLTEXT/2020/09000/COMPARISON_OF_TELFA_ROLLING_AND_A_CLOSED_WASHING.4.ASPX. ADDITIONAL INFORMATION: H.6 F2303. THIS EVENT IS BEING REPORTED FOR SERIOUS INJURY. FOLLOW UPS WERE PERFORMED WITH CORRESPONDENT AUTHOR AND TO DATE, NO RESPONSE WAS PROVIDED. DEVICES WERE NOT RETURNED FOR EVALUATION. LOT (S) NUMBER REMAINS UNKNOWN; THEREFORE, NO INTERNAL INVESTIGATION CAN BE PERFORMED. BASED ON THE AVAILABLE INFORMATION, A RELATIONSHIP BETWEEN THE REVOLVE DEVICE (S) AND THE EVENT CANNOT BE DETERMINED. IF ADDITIONAL INFORMATION IS PROVIDED, A FOLLOW UP REPORT WILL BE SEND. NO FURTHER ACTIONS ARE REQUIRED AS A NONCONFORMANCE COULD NOT BE CONFIRMED.
DURING A LITERATURE REVIEW OF AN ARTICLE TITLED, ¿COMPARISON OF TELFA ROLLING AND A CLOSED WASHING SYSTEM FOR AUTOLOGOUS FAT PROCESSING TECHNIQUES IN POSTMASTECTOMY BREAST RECONSTRUCTION¿ A STUDY OF 186 PATIENTS PERFORMED FROM JANUARY 2013 TO SEPTEMBER 2017 AIMED TO COMPARE THE COMMONLY USED FAT GRAFTING TECHNIQUES¿TELFA ROLLING AND A CLOSED WASHING SYSTEM¿IN BREAST RECONSTRUCTION PATIENTS. THE RESULT OF THE STUDY REVEALED THAT THERE WAS NO DIFFERENCE IN DEMOGRAPHICS, NUMBER OF PROCEDURES PERFORMED, VOLUME OF FAT GRAFTED, AND NUMBER OF DAYS AFTER RECONSTRUCTION THAT FAT GRAFTING WAS PERFORMED BETWEEN GROUPS (P > 0.05). TELFA ROLLING PATIENTS HAD LONGER OPERATIVE TIMES FOR SECOND FAT GRAFTING PROCEDURES (IMPLANT EXCHANGE OFTEN COMPLETED PRIOR) [100.0 MINUTES (RANGE, 60.0 TO 150.0 MINUTES) VERSUS 79.0 MINUTES (RANGE,64.0 TO 94.0 MINUTES); P = 0.03]. TELFA ROLLING BREASTS HAD MORE PALPABLE MASSES REQUIRING IMAGING (26.0 PERCENT VERSUS 14.4 PERCENT; P = 0.01) AND AN INCREASED INCIDENCE OF FAT NECROSIS (20.6 PERCENT VERSUS 8.0 PERCENT; P < 0.01). THE CLOSED WASHING SYSTEM WAS FOUND TO BE AN INDEPENDENT PREDICTOR OF DECREASED RATES OF IMAGING-CONFIRMED FAT NECROSIS (OR, 0.29; P = 0.048). THERE WAS NO DIFFERENCE IN FAT NECROSIS EXCISION OR CANCER RECURRENCE BETWEEN THE GROUPS. SOME OF THE PATIENTS HAD THE FOLLOWING COMPLICATIONS: SURGICAL SITE INFECTION REQUIRING ORAL AND IV ANTIBIOTICS, DRAINAGE, SEROMA, HEMATOMA, SKIN NECROSIS, PALPABLE MASS REQUIRING CORE BIOPSY AND PERSISTENT PAIN. CONCLUSION: THE CLOSED WASHING SYSTEM WAS INDEPENDENTLY ASSOCIATED WITH DECREASED RATES OF IMAGING-CONFIRMED FAT NECROSIS COMPARED TO TELFA ROLLING WITHOUT AN INCREASE IN OTHER COMPLICATIONS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1890524 | UNKNOWN REVOLVE | SYSTEM, SUCTION, LIPOPLASTY | MUU | LIFECELL | NI |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |