FDA Adverse Event Malfunction Summary report: N

CARDIOHELP

MDR report key: 17660458 · Received August 31, 2023

Report

Report Number
8010762-2023-00435
Event Type
Malfunction
Date Received
August 31, 2023
Date of Event
April 27, 2023
Report Date
August 31, 2023
Manufacturer
MAQUET CARDIOPULMONARY GMBH
Product Code
DTQ
PMA / PMN Number
K133598
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
TX, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

IT WAS REPORTED THAT THE ALARM AUDIO IS NOT WORKING. INITALLY NO PATIENT INVOLVEMENT WAS REPORTED. ON 2023-08-14 THE INFORMATION RECEIVED, THAT THE CARDIOHELP WAS EXCHANGED DURING TREATMENT. A GETINGE FIELD SERVICE TECHNICIAN (FST) WAS SENT FOR INVESTIGATION AND REPAIR. THE FAILURE COULD BE REPLICATED AND THE MAIN SPEAKER WAS REPLACED. THE FST PERFORMED SAFETY, CALIBRATION, AND FUNCTIONALITY CHECKS TO FACTORY SPECIFICATIONS. ALL FUNCTION TESTS ARE PASSED. THE PROVIDED LOG FILES DOES NOT INCLUDE THE REPORTED DATE OF EVENT: (B)(6) 2023. THE EVENT DATE WAS CONFIRMED BY GETINGE SERVICE AND SALES UNIT AND NO MORE LOG FILES COULD BE PROVIDED. THUS A LOG FILE ANALYSES COULD NOT BE PERFORMED FOR THE REPORTED EVENT DATE. ACCORDING TO THE RISK FILE V24 OF THE CARDIOHELP DEVICE (DMS# 2021972) THE FOLLOWING ROOT CAUSES CAN LEAD TO THE REPORTED FAILURE: EXISTING ALARMS NOT RECOGNIZED CAUSED BY TECHNICAL ERROR FOR EXAMPLE: INSUFFICIENT ALARM SYSTEM, LOUDSPEAKER FAILURE, SOUND POLLUTION. FURTHER, IN THE "INSTRUCTIONS FOR USE (IFU, CHAPTER 4.7 "SWITCHING ON THE CARDIOHELP-I, SELF TEST") IT IS STATED THAT THE SPEAKER HAS TO BE CHECKED DURING THE SELF TEST OF THE CARDIOHELP. THUS, A DEFECT SPEAKER WILL NORMALLY BE NOTICED BEFORE USE. FURTHER THE SPEAKER SHOULD BE CHECKED EVERY DAY DURING USE (REFER IFU, CHAPTER 2.2.6). THE DEVICE WAS MANUFACTURED ON 2022-01-18. THE DEVICE HISTORY RECORD (DHR) OF THE CARDIOHELP WAS REVIEWED ON 2023-05-09. THERE IS NO INDICATION THAT MANUFACTURING ISSUES OCCURRED, THUS PRODUCTION RELATED INFLUENCES ARE UNLIKELY TO HAVE CONTRIBUTED TO THE REPORTED FAILURE. BASED ON THE RESULTS THE REPORTED FAILURE "ALARM AUDIO IS NOT WORKING" COULD BE CONFIRMED. THE CUSTOMER WILL BE INFORMED ABOUT THE RESULTS BY THE GETINGE SALES AND SERVICE UNIT. THE OCCURRENCE RATE WAS CALCULATED FOR THE REPORTED ISSUE AND IT WAS DETERMINED THAT THIS IS NOT A SYSTEMIC ISSUE. THEREFORE, NO REMEDIAL ACTION IS REQUIRED. THE OCCURRENCE RATE RELATED TO THE REPORTED ISSUE IS CURRENTLY BEING MONITORED AS PART OF MAQUET CARDIOPULMONARY¿ S TRENDING PROGRAM AND ADDITIONAL INVESTIGATIONS OR CORRECTIONS WILL BE IMPLEMENTED IN CASE OF ADVERSE TRENDING.

Description of Event or Problem · 0

INFORMATION RECEIVED, THAT A PATIENT WAS INVOLVED AND THE CARDIOHELP WAS EXCHANGED DURING TREATMENT. THE CUSTOMER NOTICED THAT THERE WAS A VISUAL ALARM, BUT NO AUDIBLE ALARM. THEY DID NOT TRY THE EMERGENCY DRIVE BECAUSE THE UNIT WAS FUNCTIONING PROPERLY, BESIDES THE AUDIBLE ALARM. THE UNIT WAS REPLACED WITH A DIFFERENT CARDIOHELP. NO HARM TO ANY PERSON HAS BEEN REPORTED. COMPLAINT ID: (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1009523 CARDIOHELP CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS DTQ MAQUET CARDIOPULMONARY GMBH CARDIOHELP-I

Patients

Seq Age Sex Outcome Treatment
1 Unknown