FDA Adverse Event Malfunction Summary report: N

ULTRATHANE MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER

MDR report key: 17573103 · Received August 18, 2023

Report

Report Number
1820334-2023-01106
Event Type
Malfunction
Date Received
August 18, 2023
Date of Event
August 8, 2023
Report Date
December 28, 2023
Manufacturer
COOK INC
Product Code
FGE
UDI-DI
00827002095014
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

BLANK FIELDS ON THIS FORM INDICATE THE INFORMATION IS UNKNOWN OR UNAVAILABLE. G4 ¿ PMA/510(K) #: EXEMPT. THIS REPORT INCLUDES INFORMATION KNOWN AT THIS TIME. A FOLLOW-UP REPORT WILL BE SUBMITTED SHOULD ADDITIONAL, RELEVANT INFORMATION BECOME AVAILABLE. THIS REPORT IS REQUIRED BY THE FDA UNDER 21 CFR PART 803 AND IS BASED ON UNCONFIRMED INFORMATION SUBMITTED BY OTHERS. NEITHER THE SUBMISSION OF THIS REPORT NOR ANY STATEMENT CONTAINED HEREIN IS INTENDED TO BE AN ADMISSION THAT ANY COOK DEVICE IS DEFECTIVE OR MALFUNCTIONED OR THAT A DEATH OR SERIOUS INJURY OCCURRED; NOR IS IT ADMISSION THAT ANY COOK DEVICE CAUSED, CONTRIBUTED TO, OR IS LIKELY TO CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS INJURY IF A MALFUNCTION OCCURRED.

Additional Manufacturer Narrative · 0

BLANK FIELDS ON THIS FORM INDICATE THE INFORMATION IS UNKNOWN, UNAVAILABLE, OR UNCHANGED. CORRECTION: H3 D2A - ADDITIONAL COMMON NAME: GBO CATHETER, NEPHROSTOMY, GENERAL & PLASTIC SURGERY; LJE CATHETER, NEPHROSTOMY D2B - ADDITIONAL PRODUCT CODE: GBO; LJE. G4 - PMA/510(K) #: K173035 INVESTIGATION ¿ EVALUATION IT WAS REPORTED THAT AN ULTRATHANE MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER LEAKED BETWEEN THE CAP AND THE MAC-LOC. ADDITIONAL INFORMATION REGARDING THE EVENT AND PATIENT OUTCOME IS CURRENTLY UNAVAILABLE. REVIEWS OF DOCUMENTATION INCLUDING THE COMPLAINT HISTORY, DEVICE HISTORY RECORD (DHR), QUALITY CONTROL PROCEDURES, MANUFACTURING INSTRUCTIONS (MI), AND INSTRUCTIONS FOR USE (IFU) OF THE COMPLAINT DEVICE WERE CONDUCTED DURING THE INVESTIGATION. THE COMPLAINT DEVICE WAS NOT RETURNED; THEREFORE, NO PHYSICAL EXAMINATIONS COULD BE PERFORMED. HOWEVER, A DOCUMENT-BASED INVESTIGATION EVALUATION WAS PERFORMED. A REVIEW OF THE DEVICE MASTER RECORD (DMR) CONCLUDED THAT SUFFICIENT INSPECTION ACTIVITIES ARE IN PLACE TO IDENTIFY THIS FAILURE MODE PRIOR TO DISTRIBUTION. A REVIEW OF THE DHRS FOR THE REPORTED COMPLAINT DEVICE LOT AND THE RELATED SUBASSEMBLY LOTS REVEALED NO RELEVANT NON-CONFORMANCES. TO DATE, THERE HAS BEEN NO ADDITIONAL COMPLAINTS RECEIVED FROM THIS LOT. COOK REVIEWED THE PRODUCT LABELING FOR THE COMPLAINT DEVICE. THE INSTRUCTIONS FOR USE (IFU) [ T_MULTI2_REV1, MULTIPURPOSE DRAINAGE CATHETER] STATES THE FOLLOWING IN RELATION TO THE REPORTED FAILURE MODE: "PRECAUTIONS PATIENTS WITH INDWELLING DRAINAGE CATHETERS SHOULD BE EVALUATED ROUTINELY TO ENSURE CONTINUOUS FUNCTION OF THE CATHETER. HOW SUPPLIED UPON REMOVAL FROM PACKAGE, INSPECT THE PRODUCT TO ENSURE NO DAMAGE HAS OCCURRED." THE INFORMATION PROVIDED UPON REVIEW OF THE DMR, IFU, AND DHR, SUGGESTS THAT THE DEVICE WAS NOT MANUFACTURED OUT OF SPECIFICATION, AND THAT THERE ARE NO NONCONFORMING DEVICES IN HOUSE OR OUT IN THE FIELD. BASED ON THE INFORMATION PROVIDED, NO PRODUCT RETURNED, AND THE RESULTS OF THE INVESTIGATION, THE CAUSE OF THIS EVENT IS COMPONENT FAILURE UNRELATED TO MANUFACTURING OR DESIGN DEFICIENCIES. THE APPROPRIATE PERSONNEL HAVE BEEN NOTIFIED. COOK WILL CONTINUE TO MONITOR FOR SIMILAR COMPLAINTS. PER THE RISK ASSESSMENT NO FURTHER ACTION IS REQUIRED. THIS REPORT IS REQUIRED BY THE FDA UNDER 21 CFR PART 803 AND IS BASED ON UNCONFIRMED INFORMATION SUBMITTED BY OTHERS. NEITHER THE SUBMISSION OF THIS REPORT NOR ANY STATEMENT CONTAINED HEREIN IS INTENDED TO BE AN ADMISSION THAT ANY COOK DEVICE IS DEFECTIVE OR MALFUNCTIONED, THAT A DEATH OR SERIOUS INJURY OCCURRED, NOR THAT ANY COOK DEVICE CAUSED, CONTRIBUTED TO, OR IS LIKELY TO CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS INJURY IF A MALFUNCTION OCCURRED.

Description of Event or Problem · 0

IT WAS REPORTED THAT AN ULTRATHANE MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER LEAKED BETWEEN THE CAP AND THE MAC-LOC. ADDITIONAL INFORMATION REGARDING THE EVENT AND PATIENT OUTCOME HAS BEEN REQUESTED BUT IS CURRENTLY UNAVAILABLE.

Description of Event or Problem · 0

NO ADDITIONAL INFORMATION REGARDING THE PATIENT AND/OR EVENT HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2167631 ULTRATHANE MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER FGE CATHETER, BILIARY, DIAGNOSTIC FGE COOK INC N/A 15378479 00827002095014
2263614 ULTRATHANE MAC-LOC LOCKING LOOP MULTIPURPOSE DRAINAGE CATHETER FGE CATHETER, BILIARY, DIAGNOSTIC FGE COOK INC N/A 15378479 00827002095014

Patients

Seq Age Sex Outcome Treatment
1 Unknown