QUANTUM®
Report
- Report Number
- 3010470577-2023-07151
- Event Type
- Injury
- Date Received
- August 17, 2023
- Date of Event
- June 6, 2023
- Report Date
- September 22, 2023
- Manufacturer
- IN2BONES SAS
- Product Code
- HSN
- PMA / PMN Number
- K191380
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FR
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
INVESTIGATIONS ARE IN-PROGRESS. A COMPLETE AND FINAL MDR-REPORT WILL BE SUBMITTED WHEN ALL INVESTIGATIONS ARE PERFORMED.
THE QUANTUM® TOTAL ANKLE PROSTHESIS IS INDICATED AS A TOTAL ANKLE REPLACEMENT IN PRIMARY OR REVISION SURGERY FOR PATIENTS WITH ANKLE JOINTS DAMAGED BY SEVERE RHEUMATOID, POST-TRAUMATIC, OR DEGENERATIVE ARTHRITIS. THE QUANTUM® TOTAL ANKLE PROSTHESIS IS A FIXED-BEARING, SEMI-CONSTRAINT ANKLE PROTHESIS WITH 2 COMPONENTS AND COMPOSED OF: - A TIBIAL COMPONENT COMPOSED OF A METALLIC (TA6V) TIBIAL TRAY IMPLANT FIXED TO A POLYMER (UHWMPE) INSERT, - A METALLIC (COCR) TALAR IMPLANT REPRODUCING THE TALUS DOME ANATOMY. WHEN ALL COMPONENTS ARE IMPLANTED, WITH THE INSERT RIGIDLY LOCKED TO THE TIBIAL TRAY, THE POLYETHYLENE INSERT ACTS AS A SINGLE BEARING ALONG THE TALAR DOME, ENABLING FLEXION/EXTENSION AND ROTATION MOVEMENT AT THE REPLACED ANKLE JOINT. EACH COMPONENT OF THE QUANTUM® TOTAL ANKLE PROSTHESIS EXISTS IN DIFFERENT SIZES AND MODELS. EVENT DESCRIPTION : A FRENCH SURGEON REPORTED THAT ONE OF HIS PATIENT HAS A MIGRATION OF HER QUANTUM TIBIAL IMPLANT, ASSOCIATED TO PAIN, AT HER 6 MONTHS POSTOPERATIVE FOLLOW-UP VISIT. A REVISION SURGERY MIGHT BE PERFORMED LATER. ADDITIONAL INFORMATION ARE TO BE COLLECTED AND INVESTIGATIONS ARE IN PROGRESS.
THE QUANTUM® TOTAL ANKLE PROSTHESIS IS INDICATED AS A TOTAL ANKLE REPLACEMENT IN PRIMARY OR REVISION SURGERY FOR PATIENTS WITH ANKLE JOINTS DAMAGED BY SEVERE RHEUMATOID, POST-TRAUMATIC, OR DEGENERATIVE ARTHRITIS. THE QUANTUM® TOTAL ANKLE PROSTHESIS IS A FIXED-BEARING, SEMI-CONSTRAINT ANKLE PROTHESIS WITH 2 COMPONENTS AND COMPOSED OF: A TIBIAL COMPONENT COMPOSED OF A METALLIC (TA6V) TIBIAL TRAY IMPLANT FIXED TO A POLYMER (UHWMPE) INSERT, A METALLIC (COCR) TALAR IMPLANT REPRODUCING THE TALUS DOME ANATOMY. WHEN ALL COMPONENTS ARE IMPLANTED, WITH THE INSERT RIGIDLY LOCKED TO THE TIBIAL TRAY, THE POLYETHYLENE INSERT ACTS AS A SINGLE BEARING ALONG THE TALAR DOME, ENABLING FLEXION/EXTENSION AND ROTATION MOVEMENT AT THE REPLACED ANKLE JOINT. EACH COMPONENT OF THE QUANTUM® TOTAL ANKLE PROSTHESIS EXISTS IN DIFFERENT SIZES AND MODELS. EVENT DESCRIPTION : A FRENCH SURGEON REPORTED THAT ONE OF HIS PATIENT HAS A MIGRATION OF HER QUANTUM TIBIAL IMPLANT, ASSOCIATED TO PAIN, AT HER 6 MONTHS POSTOPERATIVE FOLLOW-UP VISIT. A REVISION SURGERY MIGHT BE PERFORMED LATER.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1792063 | QUANTUM® | QUANTUM® TOTAL ANKLE PROSTHESIS | HSN | IN2BONES SAS | M50 ST221 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 54 YR | Female | Required Intervention |