STEALTHSTATION® S7¿
Report
- Report Number
- 1723170-2023-01269
- Event Type
- Malfunction
- Date Received
- July 18, 2023
- Date of Event
- May 15, 2023
- Report Date
- July 18, 2023
- Manufacturer
- MEDTRONIC NAVIGATION, INC
- Product Code
- HAW
- PMA / PMN Number
- K050438
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- SP
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
A2) PATIENT AGE IS THE MEAN VALUE OF PATIENTS IN THE STUDY. A3) PATIENT GENDER IS THE MAJORITY VALUE OF PATIENT IN THE STUDY. A4) PATIENT WEIGHT NOT AVAILABLE FROM THE SITE. B3) EVENT DATE IS THE ONLINE ACCEPTED DATE OF THE LITERATURE ARTICLE. D4) DEVICE LOT NUMBER, OR SERIAL NUMBER, UNAVAILABLE. H3,H6) NO PARTS HAVE BEEN RECEIVED BY THE MANUFACTURER FOR EVALUATION. H4) DEVICE MANUFACTURING DATE IS DEPENDENT ON LOT NUMBER/SERIAL NUMBER, THEREFORE, UNAVAILABLE. MEDTRONIC IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ¿DEFECTS¿ OR HAS ¿MALFUNCTIONED¿. THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REGULATORY REPORTING. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE THEM BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
AIBAR-DURAN, J.A., COLLADO, I.C., BEJARANO, A.R., NEVADO, R.S., BOLANOS, I.A., GARCFA-COMET, J., ALONSO-SOLFS, A., BELLO, E.M.G., QUINTANA SCHMIDT, C., HERNANDEZ, F.M., TEIXIDO, J.M., RODRIGUEZ. R.R. LONG-TERM OUTCOMES OF DEEP BRAIN STIMULATION FOR TREATMENT-RESISTANT SCHIZOPHRENIA: EXPLORING POTENTIAL TARGETS. JOURNAL OF PSYCHIATRIC RESEARCH. 2023. 163 (296-304) HTTPS://DOI.ORG/10.1016/J.JPSY CHIRES.2023.05.056 ABSTRACT: BACKGROUND: SCHIZOPHRENIA IS A COMPLEX AND DISABLING DISORDER. AROUND 30% OF PATIENTS HAVE TREATMENT-RESISTANT SCHIZOPHRENIA (TRS). OBJECTIVE: THIS STUDY SUMMARIZES THE OUTCOMES AFTER THREE YEARS FOLLOW-UP OF THE FIRST SERIES OF PATIENTS WITH TRS TREATED WITH DEEP BRAIN STIMULATION (DBS) AND DISCUSS SURGICAL, CLINICAL AND IMAGING ANALYSIS. METHODS: EIGHT PATIENTS WITH TRS TREATED WITH DBS IN THE NUCLEUS ACCUMBENS (NACC) OR THE SUBGENUAL CINGULATE GYRUS (SCG) WERE INCLUDED. SYMPTOMS WERE RATED WITH THE PANSS SCALE AND NORMALIZED USING THE ILLNESS DENSITY INDEX (IDI). A REDUCTION IN IDI-PANSS OF 2:25% COMPARED TO BASELINE WAS THE CRITERION OF GOOD RESPONSE. THE VOLUME OF ACTIVATED TISSUE WAS CALCULATED TO PERFORM A CONNECTOMIC ANALYSIS FOR EACH PATIENT. AN ESTIMATION OF THE TRACTS AND CORTICAL AREAS MODULATED WAS GENERATED. RESULTS: FIVE WOMEN AND THREE MEN WERE ANALYZED. AFTER 3 YEARS' FOLLOW-UP, POSITIVE SYMPTOMS IMPROVED IN 50% OF THE SCG GROUP AND 75% OF THE NACC GROUP (P = 0.06), AND GENERAL SYMPTOMS IMPROVED IN 25% AND 50% RESPECTIVELY (P = 0.06). THE SCG GROUP SHOWED ACTIVATION OF THE CINGULATE BUNDLE AND MODULATION OF ORBITOFRONTAL AND FRONTOMESIAL REGIONS; IN CONTRAST, THE NACC GROUP SHOWED ACTIVATION OF THE VENTRAL TEGMENTAL AREA PROJECTIONS PATHWAY AND MODULATION OF REGIONS ASSOCIATED WITH THE "DEFAULT MODE NETWORK" (PRECUNEUS) AND BRODMANN AREAS 19 AND 20. CONCLUSIONS: THESE RESULTS SHOWED A TREND TOWARD IMPROVEMENT FOR POSITIVE AND GENERAL SYMPTOMS IN PATIENTS WITH TRS TREATED WITH DBS. THE CONNECTOMIC ANALYSIS WILL HELP US UNDERSTAND THE INTERACTION OF THIS TREATMENT WITH THE DISEASE TO PURSUE FUTURE TRIAL DESIGNS. REPORTABLE EVENTS: ALL LEADS WERE SATISFACTORY PLACED BUT ONE (IN THE NACC GROUP) WHICH WAS LOCATED POSTERIOR AND DORSAL TO THE VENTRAL STRIATUM (RATHER PLACED IN THE ANTERIOR LIMB OF THE INTERNAL CAPSULE, ALIC) HOWEVER THE PATIENT REFUSED TO BE RE-OPERATED. PLEASE SEE ATTACHED LITERATURE ARTICLE
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 170273 | STEALTHSTATION® S7¿ | NEUROLOGICAL STEREOTAXIC INSTRUMENT | HAW | MEDTRONIC NAVIGATION, INC | 9733858 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 43 YR | Female |