FDA Adverse Event Malfunction Summary report: N

4.5MM HEALIX ADVANCE¿ BR ANCHOR WITH DYNACORD¿ SUTURE (BLU,WHT/BLU/GRN,WHT/BLK)

MDR report key: 17270485 · Received July 6, 2023

Report

Report Number
1221934-2023-02627
Event Type
Malfunction
Date Received
July 6, 2023
Date of Event
June 15, 2023
Manufacturer
MEDOS INTERNATIONAL SARL
Product Code
MAI
UDI-DI
10886705029396
PMA / PMN Number
K173859
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CO, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THIS REPORT IS BEING SUBMITTED IN PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY DEPUY MITEK OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY MITEK, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. H10 ADDITIONAL NARRATIVE: D9, H3, H6: THE ACTUAL DEVICE HAS BEEN RETURNED AND IS CURRENTLY PENDING EVALUATION. ONCE RELIABILITY ENGINEERING EVALUATES THE DEVICE, A SUPPLEMENTAL MEDWATCH REPORT WILL BE SENT ACCORDINGLY. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 0

THIS REPORT IS BEING SUBMITTED IN PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY DEPUY MITEK OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY MITEK, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. H10 ADDITIONAL NARRATIVE: UDI: (B)(4). E3: REPORTER IS A J&J SALES REPRESENTATIVE. TO DATE THE DEVICE HAS NOT BEEN RETURNED. IF THE DEVICE OR FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT.

Additional Manufacturer Narrative · 0

THIS REPORT IS BEING SUBMITTED IN PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY DEPUY MITEK OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY MITEK, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. H10 ADDITIONAL NARRATIVE: INVESTIGATION SUMMARY THE PRODUCT WAS RETURNED TO MITEK FOR EVALUATION. MITEK THEN CONDUCTED VISUAL INSPECTION OF DEVICE RECEIVED. VISUAL OBSERVATION REVELATED THAT THE ANCHOR WAS CRACKED NEAR THE DISTAL PART BUT IS HELD IN PLACE BY SUTURE; THEREFORE, THIS COMPLAINT CAN BE CONFIRMED. ALSO, IT WAS SLIGHLY BENT. A MANUFACTURING RECORD EVALUATION WAS PERFORMED FOR THE FINISHED DEVICE LOT NUMBER: 9L52767, AND NO NONCONFORMANCES WERE IDENTIFIED. BASED ON THE CONDITION OF THE ANCHOR, THIS COMPLAINT CANNOT BE CONFIRMED. THE POSSIBLE ROOT CAUSE OF THE DAMAGE IN THE ANCHOR CAN BE ASSOCIATED TO PROCEDURAL VARIABLES, SUCH HANDLING OF THE DEVICE OR PRODUCT INTERACTION DURING PROCEDURE. MOREOVER, WITH OFF AXIS INSERTION AND LEVERING DURING INSERTION COULD HAVE RESULTED DAMAGE THE ANCHOR. HOWEVER, IT CANNOT BE CONCLUSIVELY AFFIRMED. AS PER IFU, INSERTING THE AWL OR DRILL TO LESS THAN THE SPECIFIED DEPTH, AXIAL MISALIGNMENT, OR LEVERING WITH THE ANCHOR UPON INSERTION MAY RESULT IN ANCHOR FRACTURE. DO NOT APPLY A BENDING FORCE TO THE INSERTER. THIS CAN DAMAGE THE ANCHOR OR INSERTER TIP. AS PART OF MITEK¿S QUALITY PROCESS ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS. AT THIS POINT IN TIME, NO CORRECTIVE ACTION IS REQUIRED, AND NO FURTHER ACTION IS WARRANTED. HOWEVER, IN DEPUY SYNTHES MITEK, ADDITIONAL COMPLAINT INFORMATION MONITORING FOR POTENTIAL SAFETY SIGNALS IS CONDUCTED THROUGH COMPLAINT TRENDING AS PART OF POST MARKET SURVEILLANCE.

Description of Event or Problem · 0

IT WAS REPORTED BY THE USER FACILITY EMPLOYEE THAT DURING A SHOULDER ARTHROSCOPY PROCEDURE ON (B)(6)2023, IT WAS OBSERVED THAT THE 4.5MM HEALIX ADVANCE¿ BR ANCHOR WITH DYNACORD¿ SUTURE (BLUE, WHITE/BLUE/GREEN, WHITE/BLACK) DEVICE BROKE UPON INSERTION INTO THE PATIENT. IT WAS UNKNOWN IF AND HOW THE PROCEDURE WAS COMPLETED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2030482 4.5MM HEALIX ADVANCE¿ BR ANCHOR WITH DYNACORD¿ SUTURE (BLU,WHT/BLU/GRN,WHT/BLK) SOFT-TISSUE ANCHOR, BIOABSORBABLE MAI MEDOS INTERNATIONAL SARL 222002 9L52767 10886705029396

Patients

Seq Age Sex Outcome Treatment
1 Unknown