FDA Adverse Event Injury Summary report: N

TORNIER PERFORM REVERSED LATER ALIZED BASEPLATE 3MM DIA 25MM

MDR report key: 17199811 · Received June 26, 2023

Report

Report Number
3000931034-2023-00188
Event Type
Injury
Date Received
June 26, 2023
Date of Event
May 30, 2023
Report Date
August 31, 2023
Manufacturer
TORNIER S.A.S.
Product Code
PHX
UDI-DI
00846832092123
PMA / PMN Number
K161742
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THE REPORTED EVENT WAS NOT CONFIRMED SINCE THE DEVICES WERE NOT RETURNED FOR EVALUATION AND NO OTHER EVIDENCES WERE PROVIDED. SINCE THIS EVENT IS A PARTICULAR ISSUE, THE OPINION OF THE MEDICAL EXPERT WAS REQUESTED WITH THE LIMITED INFORMATION AVAILABLE AND STATED AS FOLLOWING: ¿PLEASE NOTE THAT MANY PATIENTS HAVE NERVE LESIONS AFTER PHF (PROXIMAL HUMERAL FRACTURE). THESE NERVE LESIONS ARE USUALLY NOT NOTED BECAUSE OF THE FRACTURE (JOINT DOESN'T FUNCTION PROPERLY) AND THE PAIN (THESE FRACTURES ARE VERY PAINFUL). THEREFORE, IT CANNOT BE TESTED BY PHYSICAL EXAMINATION. THERE ARE STUDIES HOWEVER, SHOWING WITH ELECTROMYOGRAPHY (EMG) THAT PATIENTS WITH PHF HAVE SOME NEUROLOGICAL LESIONS IN 40-60% OF THE TIME. MOST OF THEM RESOLVE SPONTANEOUSLY IN 3-6 MONTHS. PERSISTING AXILLARY NERVE INJURIES ARE THOUGHT TOP BE IN 5-10% OF CASES. SINCE WE HAVE NO EMG STUDY OF THIS PATIENT POST-TRAUMA IT CANNOT BE ASSESSED IF THIS EVENT IS RELATED TO THE IMPLANT PROCEDURE AT ALL". A REVIEW OF THE DEVICE HISTORY FOR THE REPORTED LOT DID NOT INDICATE ANY ABNORMALITIES. NO CORRECTIVE ACTIONS ARE REQUIRED AT THIS TIME. A REVIEW OF THE LABELING DID NOT INDICATE ANY ABNORMALITIES. NO INDICATIONS OF MATERIAL, MANUFACTURING OR DESIGN RELATED PROBLEMS WERE FOUND DURING THE INVESTIGATION. MORE DETAILED INFORMATION ABOUT THE COMPLAINT EVENT AS WELL AS THE AFFECTED DEVICES MUST BE AVAILABLE IN ORDER TO DETERMINE THE ROOT CAUSE OF THE COMPLAINT EVENT. IF MORE INFORMATION IS PROVIDED, THE CASE WILL BE REASSESSED.

Additional Manufacturer Narrative · 0

THE DEVICE WILL NOT BE RETURNED. IF ADDITIONAL INFORMATION BECOMES AVAILABLE, IT WILL BE PROVIDED IN A SUPPLEMENTAL REPORT. H3 OTHER TEXT : DEVICE DISPOSITION IS UNKNOWN.

Description of Event or Problem · 0

A REVISION SURGERY WAS PERFORMED USING THE BLUEPRINT PLANNING FEATURE: THIS PATIENT¿S INITIAL SURGERY WAS A REVERSE FOR FRACTURE , THE LONG FLEX WAS USED. PATIENT SEEMED TO BE DOING FINE BUT NOTICED ISSUES. TESTS WERE DONE AN FOUND THAT THE AXILLARY NERVE HAD SUFFERED SOME DAMAGE WHEN THE PATIENT WAS REFERRED TO THE OPERATING SURGEON. FROM THERE THE SURGEON STAGED IT WITH A SPACER TO GET A NEW BLUEPRINT SO THE SURGEON COULD DO THE REVISION, BASEPLATE WAS NOT PLACED WELL SO THE SURGEON WANTED TO START OVER.

Description of Event or Problem · 0

A REVISION SURGERY WAS PERFORMED USING THE BLUEPRINT PLANNING FEATURE: THIS PATIENT¿S INITIAL SURGERY WAS A REVERSE FOR FRACTURE NOT DONE BY DR. (B)(6), LONG FLEX WAS USED. PATIENT SEEMED TO BE DOING FINE BUT NOTICED ISSUES. TESTS WERE DONE AN FOUND THAT THE AXILLARY NERVE HAD SUFFERED SOME DAMAGE WHEN THE PATIENT WAS REFERRED TO (B)(6). FROM THERE THE SURGEON STAGED IT WITH A SPACER TO GET A NEW BLUEPRINT SO THE SURGEON COULD DO THE REVISION, BASEPLATE WAS NOT PLACED WELL SO THE SURGEON WANTED TO START OVER.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1221991 TORNIER PERFORM REVERSED LATER ALIZED BASEPLATE 3MM DIA 25MM SHOULDER PROSTHESIS, REVERSE CONFIGURATION PHX TORNIER S.A.S. 3828AX 00846832092123

Patients

Seq Age Sex Outcome Treatment
1 Unknown Required Intervention