FDA Adverse Event Injury Summary report: N

1.5/0.6 2MM LEFORT PLATE

MDR report key: 17171955 · Received June 21, 2023

Report

Report Number
0001032347-2023-00238
Event Type
Injury
Date Received
June 21, 2023
Date of Event
March 28, 2023
Report Date
August 30, 2024
Manufacturer
BIOMET MICROFIXATION
Product Code
JEY
UDI-DI
00841036011680
PMA / PMN Number
K121589
Removal / Correction Number
N/A
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

ZIMMER BIOMET COMPLAINT (B)(4). D10 ¿ MEDICAL PRODUCTS: ITEM # 01-6482, LOT # 161370; 1.5/0.6 2MM LEFORT PLATE; QTY 2; ITEM # 95-1805, LOT # 273127F; 1.8X5MM HT X-DR SCREW; ITEM # 95-1505, LOT # 273727F; 1.5X5MM HT X-DR SCREW; QTY 21. G2: FOREIGN: JAPAN. CUSTOMER HAS INDICATED THAT THE PRODUCT IS IN PROCESS OF BEING RETURNED TO ZIMMER BIOMET FOR INVESTIGATION. ONCE THE INVESTIGATION HAS BEEN COMPLETED, A FOLLOW-UP MDR WILL BE SUBMITTED. MULTIPLE MDR REPORTS WERE FILED FOR THIS EVENT, PLEASE SEE ASSOCIATED REPORTS: 0001032347-2023-00237; 0001032347-2023-00238; 0001032347-2023-00239; 0001032347-2023-00240; 0001032347-2023-00241; 0001032347-2023-00242; 0001032347-2023-00243; 0001032347-2023-00244; 0001032347-2023-00245; 0001032347-2023-00246; 0001032347-2023-00247; 0001032347-2023-00248; 0001032347-2023-00249; 0001032347-2023-00250; 0001032347-2023-00251; 0001032347-2023-00252; 0001032347-2023-00253; 0001032347-2023-00254; 0001032347-2023-00255; 0001032347-2023-00256; 0001032347-2023-00257; 0001032347-2023-00258; 0001032347-2023-00259; 0001032347-2023-00260.

Additional Manufacturer Narrative · 0

THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL INFORMATION. REVIEW OF CUSTOMER-PROVIDED PHOTOS SHOWS FRACTURES OF TWO PLATES. NO DEFECTS COULD BE CONFIRMED ON THE PHOTOS OF THE 22 REPORTED SCREWS. AS THE REASON FOR REVISION IS UNKNOWN, NO CONCLUSIONS CAN BE MADE BY THESE PHOTOS. REVIEW OF THE DEVICE HISTORY RECORD(S) IDENTIFIED NO DEVIATIONS OR ANOMALIES DURING MANUFACTURING RELATED TO THE REPORTED EVENT. A DEFINITIVE ROOT CAUSE CANNOT BE DETERMINED. THE REPORTED EVENT IS UNCONFIRMED. IF ANY FURTHER INFORMATION IS FOUND THAT WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS. THIS REPORT IS BEING SUBMITTED TO UPDATE ADDITIONAL INFORMATION IN SECTIONS B4, B5, G3, G6, H2, H3, H4, H6, AND H10.

Additional Manufacturer Narrative · 0

THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL INFORMATION. A VISUAL INSPECTION WAS CONDUCTED ON THE RETURNED PLATES AND SCREWS. BOTH PLATES AND THE SCREWS SHOW SIGNS OF ATTEMPTED USE INCLUDING MARKING AND SCRATCHING ON THE PRODUCT SURFACES. BOTH PLATES HAVE FRACTURED. THE RETURNED DEVICES WERE EVALUATED WITH OPTICAL MICROSCOPY AND SCANNING ELECTRON MICROSCOPY. SEM IMAGES OF THE FRACTURE SURFACES OF THE TWO PLATES SHOW FATIGUE STRIATIONS, SUGGESTING THE FATIGUE FAILURE MODE. SEMI QUANTITATIVE EDS ELEMENTAL ANALYSIS FOUND THE MATERIAL TO BE CONSISTENT WITH TITANIUM WITH MINOR CARBON CONTAMINATION. FOR THE 22 RETURNED SCREWS ALL SCREWS SHOW SIGNS OF LIGHT USE WITH MINOR MARKING ON THE SCREW SURFACES. ALL SCREWS HOWEVER ARE INTACT WITH NO SIGNS OF DAMAGE. THE SCREWS ARE FULLY FUNCTIONAL WITH NO ISSUES FOUND. A DEFINITIVE ROOT CAUSE CANNOT BE DETERMINED. THE REPORTED EVENT IS CONFIRMED, BASED ON PRODUCT RETURN.

Description of Event or Problem · 0

IT IS REPORTED THAT THE PATIENT UNDERWENT A PROCEDURE, AND SUBSEQUENTLY WAS REVISED FOR AN UNKNOWN REASON. ATTEMPTS HAVE BEEN MADE AND ADDITIONAL INFORMATION ON THE REPORTED EVENT IS UNAVAILABLE AT THIS TIME.

Description of Event or Problem · 0

NO FURTHER EVENT INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.

Description of Event or Problem · 0

NO FURTHER EVENT INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1987930 1.5/0.6 2MM LEFORT PLATE PLATE, BONE JEY BIOMET MICROFIXATION N/A 161370 00841036011680

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Required Intervention| H SEE H10