FDA Adverse Event Injury Summary report: N

UNK_SMART TOUCH BIDIRECTIONAL

MDR report key: 17163978 · Received June 20, 2023

Report

Report Number
2029046-2023-01318
Event Type
Injury
Date Received
June 20, 2023
Date of Event
April 5, 2023
Report Date
June 20, 2023
Manufacturer
BIOSENSE WEBSTER INC
Product Code
LPB
PMA / PMN Number
P030031/S053
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CH
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THIS COMPLAINT IS FROM A LITERATURE SOURCE. THE FOLLOWING LITERATURE CITE HAS BEEN REVIEWED: DI C, WANG Q, WU Y, LI L, LIN W. MONITORING SPIKE POTENTIAL AND ABRUPT IMPEDANCE RISE WITH CONCOMITANT TEMPERATURE/CONTACT FORCE CHANGE FOR TIMELY DETECTION OF THE OCCURRENCE OF "SILENT" OR "NONAUDIBLE" STEAM POP. J INTERV CARDIOL. 2023 APR 5;2023:8873404. DOI: 10.1155/2023/8873404. PMID: 37064642; PMCID: PMC10098411. NO DEVICE WAS RECEIVED FOR ANALYSIS AT THE TIME OF SUBMISSION OF THE INITIAL 3500A. SINCE THE PRODUCT WAS NOT RETURNED FOR ANALYSIS, NO PRODUCT FAILURE ANALYSIS CAN BE CONDUCTED, AND NO DETERMINATION OF POSSIBLE CONTRIBUTING FACTORS COULD BE MADE. DEVICE HISTORY RECORD (DHR) REVIEW CANNOT BE CONDUCTED BECAUSE THE LOT NUMBER WAS PROVIDED BY THE CUSTOMER. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 4. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY BIOSENSE WEBSTER INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, BIOSENSE WEBSTER INC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. MANUFACTURER¿S REFERENCE NUMBER: (B)(4).

Description of Event or Problem · 0

THIS COMPLAINT IS FROM A LITERATURE SOURCE. THE FOLLOWING LITERATURE CITE HAS BEEN REVIEWED: DI C, WANG Q, WU Y, LI L, LIN W. MONITORING SPIKE POTENTIAL AND ABRUPT IMPEDANCE RISE WITH CONCOMITANT TEMPERATURE/CONTACT FORCE CHANGE FOR TIMELY DETECTION OF THE OCCURRENCE OF "SILENT" OR "NONAUDIBLE" STEAM POP. J INTERV CARDIOL. 2023 APR 5;2023:8873404. DOI: 10.1155/2023/8873404. PMID: 37064642; PMCID: PMC10098411. OBJECTIVE/METHODS/STUDY DATA:TIS STUDY SOUGHT TO ASSESS THE FEASIBILITY OF MONITORING THE RECORDED SPIKE POTENTIAL AND ABRUPT RISE IN IMPEDANCE WITH CONCOMITANT TEMPERATURE AND/OR CF CHANGE AS AN INDICATOR FORTIMELY DETECTION OF THE OCCURRENCE OF ¿SILENT¿ OR ¿NONAUDIBLE¿ SP EVENTS, PARTICULARLY IN REGIONS WHERE THE RISK OF PERFORATION MAY BE OF CONCERN. LOT, MODEL AND CATALOG NUMBER ARE NOT AVAILABLE, BUT THE SUSPECTED BIOSENSE DEVICE POSSIBLY ASSOCIATED WITH REPORTED ADVERSE EVENTS: 3.5 MM EXTERNALLY IRRIGATED-TIP ABLATION CATHETER (SMARTTOUCH, D CURVE OR F CURVE, BIOSENSE WEBSTER, DIAMOND BAR, CA, USA) OTHER BIOSENSE WEBSTER DEVICES THAT WERE ALSO USED IN THIS STUDY: DECAPOLAR MAPPING CATHETER (LASSO, BIOSENSE WEBSTER, DIAMOND BAR, CA, USA), STEERABLE SHEATH (MOBICATH, BIOSENSE WEBSTER, DIAMOND BAR, CA, USA) WAS ADVANCED ALTERNATELY ONLY WHEN THE NONSTEERABLE SHEATH COULD NOT ADVANCE THE NON-BIOSENSE WEBSTER DEVICES THAT WERE ALSO USED IN THIS STUDY: NONSTEERABLE SHEATH (8.5 F SL1, ST. JUDE MEDICAL, ST. PAUL, MN, USA) COULD NOT ADVANCE THE ADVERSE EVENT(S) AND PROVIDED INTERVENTIONS: 15 REPORTED STEAM POPS. 2 PATIENTS DEVELOPED PERICARDIAL TAMPONADE AND UNDERWENT DRAINAGE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1013380 UNK_SMART TOUCH BIDIRECTIONAL CARDIAC ABLATION PERCUTANEOUS CATHETER LPB BIOSENSE WEBSTER INC

Patients

Seq Age Sex Outcome Treatment
1 Unknown Life Threatening DECAPOLAR MAPPING CATHETER.| NONSTEERABLE SHEATH (8.5 F SL1, ST. JUDE MEDICAL.| STEERABLE SHEATH (MOBICATH).