FDA Adverse Event Malfunction Summary report: N

UNKNOWN

MDR report key: 17036253 · Received June 1, 2023

Report

Report Number
9680654-2023-00033
Event Type
Malfunction
Date Received
June 1, 2023
Report Date
August 10, 2023
Manufacturer
WILLIAM A. COOK AUSTRALIA, PTY LTD
Product Code
MIH
PMA / PMN Number
P020018
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

NO PART OF THE DEVICE WAS RETURNED FOR EVALUATION. ADDITIONAL INFORMATION WAS REQUESTED, BUT NO FURTHER INFORMATION WAS RECEIVED. NO IMAGING WAS RECEIVED TO ASSIST THE INVESTIGATION. MANUFACTURING RECORDS REVIEW COULD NOT BE COMPLETED AS THE LOT NUMBER IS UNKNOWN. REVIEW OF THE INSTRUCTIONS FOR USE (IFU) LIKELY SUPPLIED WITH THE DEVICE (AS THE LOT NUMBER IS UNKNOWN, THE IFU CURRENTLY SUPPLIED WITH ZFEN DEVICES WAS REVIEWED) FOUND TO CONTAIN APPROPRIATE WARNINGS, PRECAUTIONS, AND INSTRUCTIONS TO THE USER, INCLUDING: 4.3 IMPLANT PROCEDURE - INACCURATE PLACEMENT AND/OR INCOMPLETE SEALING OF THE ZENITH FENESTRATED AAA ENDOVASCULAR GRAFT WITHIN THE VESSEL MAY RESULT IN INCREASED RISK OF ENDOLEAK, MIGRATION OR INADVERTENT OCCLUSION OF THE RENAL OR INTERNAL ILIAC ARTERIES. RENAL ARTERY PATENCY MUST BE MAINTAINED TO PREVENT/REDUCE THE RISK OF RENAL FAILURE AND SUBSEQUENT COMPLICATIONS. 11. POTENTIAL ADVERSE EVENTS ADVERSE EVENTS THAT MAY OCCUR AND MAY REQUIRE INTERVENTION INCLUDE BUT ARE NOT LIMITED TO: - ENDOLEAK - ENDOPROSTHESIS: IMPROPER COMPONENT PLACEMENT; INCOMPLETE COMPONENT DEPLOYMENT; COMPONENT MIGRATION; SUTURE BREAK; OCCLUSION; INFECTION; STENT FRACTURE; GRAFT MATERIAL WEAR; DILATATION; EROSION; PUNCTURE; PERIGRAFT FLOW; BARB SEPARATION AND CORROSION. 16.1 GENERAL THE LONG-TERM PERFORMANCE OF ENDOVASCULAR GRAFTS HAS NOT YET BEEN ESTABLISHED. ALL PATIENTS SHOULD BE ADVISED THAT ENDOVASCULAR TREATMENT REQUIRES REGULAR, LIFELONG FOLLOW-UP TO ASSESS THEIR HEALTH AND THE PERFORMANCE OF THEIR ENDOVASCULAR GRAFT. PATIENTS WITH SPECIFIC CLINICAL FINDINGS (E.G., ENDOLEAKS, ENLARGING ANEURYSMS, OR CHANGES IN THE STRUCTURE OR POSITION OF THE ENDOVASCULAR GRAFT) SHOULD RECEIVE ADDITIONAL FOLLOW-UP. THERE IS NO EVIDENCE TO SUGGEST THAT THE USER DID NOT FOLLOW THE INSTRUCTIONS FOR USE. A DEFINITIVE ROOT CAUSE COULD NOT BE DETERMINED FROM THE INVESTIGATION. THIS IS A KNOWN EFFECT OF FAILURE, AND IT IS LISTED IN THE RISK DOCUMENT AND IN THE IFU. SHOULD ADDITIONAL INFORMATION BE RECEIVED AT ANY TIME IN THE FUTURE THE INVESTIGATION MAY BE UPDATED, AND AN ADDITIONAL REPORT MAY BE SUPPLIED.

Additional Manufacturer Narrative · 0

LITERATURE ARTICLE: THE JOURNAL OF CARDIOVASCULAR SURGERY 2020 OCTOBER;61(5):596-603 DOI: 10.23736/S0021-9509.19.11052-X

Description of Event or Problem · 0

RETROSPECTIVE ANALYSIS OF PATIENTS WHO UNDERWENT ELECTIVE ENDOVASCULAR REPAIR (EVAR) FOR TREATMENT OF AAA FROM 1ST JANUARY 2008 TO 31ST DECEMBER 2017 IDENTIFIED FROM THE NATIONAL VASCULAR REGISTRY (NVR¿ ANAEROBIC THRESHOLD AS AN INDEPENDENT PREDICTOR OF MIDTERM SURVIVAL FOLLOWING ELECTIVE ENDOVASCULAR REPAIR OF ABDOMINAL AORTIC ANEURYSM. DAWKINS, C., ET AL., 2020. FOUR HUNDRED AND THIRTY PATIENTS UNDERWENT ELECTIVE EVAR FOR REPAIR OF AAA OF WHOM 389 (90.5%) WERE MEN AND 41 (9.5%) WERE WOMEN. THE MEDIAN AGE OF PATIENTS WAS 76 YEARS (RANGE: 53-(B)(6) ). THE MEDIAN AAA DIAMETER AT THE TIME OF REPAIR WAS 61 MM (RANGE: 45-115). IN ADDITION TO THE STUDY POPULATION, BETWEEN (B)(6) 2008 AND (B)(6) 2017, 238 PATIENTS (216 MEN, 90.8%, 22 WOMEN, 9.2%) WITH A MEAN AGE OF 69.71±7.42 YEARS UNDERWENT ELECTIVE OPEN REPAIR OF AAA. PERIPROCEDURAL 30- DAY MORTALITY OF THESE PATIENTS WAS 1.68% (FOUR PATIENTS). INTER-OBSERVER AGREEMENT FOR CLASSIFICATION OF AAA MORPHOLOGY AS BEING WITHIN (OR OUTSIDE) THE CONSERVATIVE IFU FOR A STANDARD ENDOVASCULAR DEVICE WAS EXCELLENT (=0.83). A SIMILARLY GOOD INTER-OBSERVER CORRELATION WAS OBSERVED IN CLASSIFYING AAA MORPHOLOGY AS BEING WITHIN (OR OUTSIDE) THE LIBERAL IFU FOR STANDARD EVAR, (=0.79). THREE HUNDRED AND THIRTY-SIX PATIENTS (78.1%) HAD AORTIC ANATOMY WHICH FULFILLED A CONSERVATIVE IFU FOR STANDARD EVAR, 42 (9.8%) FULFILLED A LIBERAL INTERPRETATION OF IFU FOR EVAR AND 52 (12.1%) DID NOT MEET THE IFU FOR STANDARD INFRA RENAL EVAR. A VARIETY OF ENDOVASCULAR DEVICES WERE USED TO TREAT THESE ABDOMINAL AORTIC ANEURYSMS. EACH CASE WAS PLANNED TO MATCH THE IFU OF THE DEVICE USED. OF THE 430 PATIENTS TREATED, 374 UNDERWENT INFRA-RENAL EVAR (N.=371) OR EVAS (N.=3) AND 56 UNDERWENT COMPLEX EVAR TO EXTEND THE SEAL ZONE ABOVE THE RENAL ARTERIES (FENESTRATED EVAR OR BRANCHED STENT GRAFTS). MEDIAN DURATION OF RADIOLOGICAL FOLLOW-UP WAS 1630 DAYS (RANGE: 356-3892 DAYS). EACH PATIENT UNDERWENT A MEDIAN OF 5 (RANGE: 1-12) RADIOLOGICAL FOLLOW-UP CYCLES. THE INCIDENCE OF TYPE I ENDOLEAK AND STENT GRAFT MIGRATION DURING THE FOLLOW-UP PERIOD WAS 22 (5%) AND 13 (3%), RESPECTIVELY. IN FOUR PATIENTS, TYPE I ENDOLEAKS HAD OCCURRED DUE TO DEVICE MIGRATION; IN ADDITION, SIX GRAFT LIMBS AND TWO GRAFT BODIES HAD THROMBOSED. ONE HUNDRED AND TWENTY PATIENTS (28%) DEVELOPED TYPE II ENDOLEAKS. IN 49 PATIENTS (11.4%), THE AORTIC SAC CONTINUED TO EXPAND BY A MEDIAN OF 4 MM (2- 31 MM), WHILST IN 24 PATIENTS (5.58%) AAA SAC GROW BY IN EXCESS OF 5-MM FREEDOM FROM AAA RUPTURE AT 5 YEARS WAS 98.1% (STANDARD EVAR: 97.8%, COMPLEX EVAR: 98.2%). ONE GRAFT WAS EXPLANTED DUE TO INFECTION. THE CUMULATIVE RE-INTERVENTION RATE OVER THE DURATION OF FOLLOW-UP WAS 3.45% PER PERSON-YEARS, WHILST 5-YEAR RE-INTERVENTION FREE SURVIVAL WAS 84.3%. A TOTAL OF SIXTY-ONE RE-INTERVENTIONS WERE PERFORMED IN 59 PATIENTS (STANDARD EVAR: N.=52, COMPLEX EVAR: N.=7). NO SIGNIFICANT DIFFERENCES WERE OBSERVED IN SURVIVAL, FREEDOM FROM RUPTURE OR RE-INTERVENTION BETWEEN PATIENTS WHO UNDERWENT STANDARD EVAR AND THOSE WHO UNDERWENT COMPLEX EVAR. USE OF COOK MANUFACTURED DEVICES: ZENITH FLEX COOK MEDICAL EUROPE X 123 (28.60%) ALPHA COOK MEDICAL EUROPE X 7 (1.63%) ZENITH T BRANCH STENT¿ (COMPLEX) COOK MEDICAL EUROPE X 2 (0.47%) ZENITH FENESTRATED STENT¿ (COMPLEX) COOK MEDICAL AUSTRALIA X 51 (11.86%). A TOTAL OF 183 COOK MEDICAL DEVICES WERE IMPLANTED. (42.657% OF ALL DEVICES USED). 51 OF THOSE DEVICES WERE MANUFACTURED BY WCA. OTHER MANUFACTURERS DEVICES: EXCLUDER¿ GORE® X 168 (39.07%) ENDURANT II¿ MEDTRONIC® X 47 (10.93%) TALENT¿ MEDTRONIC® X 6 (1.40%) AORFIX¿ LOMBARD® MEDICAL X 12 (2.79%) ANACONDA¿ VASCUTEK® X 6 (1.40%) OVATION® ENDOLOGIX® X 1 (0.23%) NELLIX ® ENDOLOGIX® X 3 (0.70%) ANACONDA¿ FENESTRATED STENT (COMPLEX) VASCUTEK® X 2 (0.70%) ENDURANT II¿ CHIMNEY CONFIGURATION (COMPLEX) MEDTRONIC® X 1 (0.23%) A TOTAL OF 246 DEVICES MANUFACTURED BY OTHER COMPANIES WERE IMPLANTED. 57.343% OF ALL DEVICES USED. THIS (B)(4): A TOTAL OF 13 PATIENTS (3%) HAD STENT GRAFT MIGRATION DURING THE FOLLOW-UP PERIOD: - DEVICE MIGRATION REQUIRING A PROXIMAL EXTENSION CUFF (TUBE) IN A TOTAL OF 9 PATIENTS (15.8%). - DEVICE MIGRATION WAS REPORTED AS THE CAUSE OF TYPE I ENDOLEAK IN FOUR PATIENTS (ALSO REPORTED UNDER (B)(4) ). PLEASE NOTE THAT THE PATIENT QUANTITY FOR PATIENTS WITH DEVICE MIGRATION AS THE CAUSE OF TYPE I ENDOLEAK HAS BEEN COUNTED IN BOTH (B)(4). 26-MAY-23 MFR01.

Description of Event or Problem · 0

RETROSPECTIVE ANALYSIS OF PATIENTS WHO UNDERWENT ELECTIVE ENDOVASCULAR REPAIR (EVAR) FOR TREATMENT OF AAA FROM (B)(6) 2008 TO (B)(6) 2017 IDENTIFIED FROM THE NATIONAL VASCULAR REGISTRY (NVR¿ ANAEROBIC THRESHOLD AS AN INDEPENDENT PREDICTOR OF MIDTERM SURVIVAL FOLLOWING ELECTIVE ENDOVASCULAR REPAIR OF ABDOMINAL AORTIC ANEURYSM. DAWKINS, C., ET AL., 2020. FOUR HUNDRED AND THIRTY PATIENTS UNDERWENT ELECTIVE EVAR FOR REPAIR OF AAA OF WHOM 389 (90.5%) WERE MEN AND 41 (9.5%) WERE WOMEN. THE MEDIAN AGE OF PATIENTS WAS 76 YEARS (RANGE: 53-91). THE MEDIAN AAA DIAMETER AT THE TIME OF REPAIR WAS 61 MM (RANGE: 45-115). IN ADDITION TO THE STUDY POPULATION, BETWEEN JANUARY 1ST, 2008 AND DECEMBER 31ST, 2017, 238 PATIENTS (216 MEN, 90.8%, 22 WOMEN, 9.2%) WITH A MEAN AGE OF 69.71±7.42 YEARS UNDERWENT ELECTIVE OPEN REPAIR OF AAA. PERIPROCEDURAL 30- DAY MORTALITY OF THESE PATIENTS WAS 1.68% (FOUR PATIENTS). INTER-OBSERVER AGREEMENT FOR CLASSIFICATION OF AAA MORPHOLOGY AS BEING WITHIN (OR OUTSIDE) THE CONSERVATIVE IFU FOR A STANDARD ENDOVASCULAR DEVICE WAS EXCELLENT (¿=0.83). A SIMILARLY GOOD INTER-OBSERVER CORRELATION WAS OBSERVED IN CLASSIFYING AAA MORPHOLOGY AS BEING WITHIN (OR OUTSIDE) THE LIBERAL IFU FOR STANDARD EVAR, (¿=0.79). THREE HUNDRED AND THIRTY-SIX PATIENTS (78.1%) HAD AORTIC ANATOMY WHICH FULFILLED A CONSERVATIVE IFU FOR STANDARD EVAR, 42 (9.8%) FULFILLED A LIBERAL INTERPRETATION OF IFU FOR EVAR AND 52 (12.1%) DID NOT MEET THE IFU FOR STANDARD INFRA RENAL EVAR. A VARIETY OF ENDOVASCULAR DEVICES WERE USED TO TREAT THESE ABDOMINAL AORTIC ANEURYSMS. EACH CASE WAS PLANNED TO MATCH THE IFU OF THE DEVICE USED. OF THE 430 PATIENTS TREATED, 374 UNDERWENT INFRA-RENAL EVAR (N.=371) OR EVAS (N.=3) AND 56 UNDERWENT COMPLEX EVAR TO EXTEND THE SEAL ZONE ABOVE THE RENAL ARTERIES (FENESTRATED EVAR OR BRANCHED STENT GRAFTS). MEDIAN DURATION OF RADIOLOGICAL FOLLOW-UP WAS 1630 DAYS (RANGE: 356-3892 DAYS). EACH PATIENT UNDERWENT A MEDIAN OF 5 (RANGE: 1-12) RADIOLOGICAL FOLLOW-UP CYCLES. THE INCIDENCE OF TYPE I ENDOLEAK AND STENT GRAFT MIGRATION DURING THE FOLLOW-UP PERIOD WAS 22 (5%) AND 13 (3%), RESPECTIVELY. IN FOUR PATIENTS, TYPE I ENDOLEAKS HAD OCCURRED DUE TO DEVICE MIGRATION; IN ADDITION, SIX GRAFT LIMBS AND TWO GRAFT BODIES HAD THROMBOSED. ONE HUNDRED AND TWENTY PATIENTS (28%) DEVELOPED TYPE II ENDOLEAKS. IN 49 PATIENTS (11.4%), THE AORTIC SAC CONTINUED TO EXPAND BY A MEDIAN OF 4 MM (2- 31 MM), WHILST IN 24 PATIENTS (5.58%) AAA SAC GROW BY IN EXCESS OF 5-MM FREEDOM FROM AAA RUPTURE AT 5 YEARS WAS 98.1% (STANDARD EVAR: 97.8%, COMPLEX EVAR: 98.2%). ONE GRAFT WAS EXPLANTED DUE TO INFECTION. THE CUMULATIVE RE-INTERVENTION RATE OVER THE DURATION OF FOLLOW-UP WAS 3.45% PER PERSON-YEARS, WHILST 5-YEAR RE-INTERVENTION FREE SURVIVAL WAS 84.3%. A TOTAL OF SIXTY-ONE RE-INTERVENTIONS WERE PERFORMED IN 59 PATIENTS (STANDARD EVAR: N.=52, COMPLEX EVAR: N.=7). NO SIGNIFICANT DIFFERENCES WERE OBSERVED IN SURVIVAL, FREEDOM FROM RUPTURE OR RE-INTERVENTION BETWEEN PATIENTS WHO UNDERWENT STANDARD EVAR AND THOSE WHO UNDERWENT COMPLEX EVAR. USE OF COOK MANUFACTURED DEVICES: ZENITH FLEX COOK MEDICAL EUROPE X 123 (28.60%) ALPHA COOK MEDICAL EUROPE X 7 (1.63%) ZENITH T BRANCH STENT¿ (COMPLEX) COOK MEDICAL EUROPE X 2 (0.47%) ZENITH FENESTRATED STENT¿ (COMPLEX) COOK MEDICAL AUSTRALIA X 51 (11.86%) A TOTAL OF 183 COOK MEDICAL DEVICES WERE IMPLANTED. (42.657% OF ALL DEVICES USED). 51 OF THOSE DEVICES WERE MANUFACTURED BY WCA. OTHER MANUFACTURERS DEVICES: EXCLUDER¿ GORE® X 168 (39.07%) ENDURANT II¿ MEDTRONIC® X 47 (10.93%) TALENT¿ MEDTRONIC® X 6 (1.40%) AORFIX¿ LOMBARD® MEDICAL X 12 (2.79%) ANACONDA¿ VASCUTEK® X 6 (1.40%) OVATION® ENDOLOGIX® X 1 (0.23%) NELLIX ® ENDOLOGIX® X 3 (0.70%) ANACONDA¿ FENESTRATED STENT (COMPLEX) VASCUTEK® X 2 (0.70%) ENDURANT II¿ CHIMNEY CONFIGURATION (COMPLEX) MEDTRONIC® X 1 (0.23%) A TOTAL OF 246 DEVICES MANUFACTURED BY OTHER COMPANIES WERE IMPLANTED. 57.343% OF ALL DEVICES USED. THIS (B)(4): A TOTAL OF 13 PATIENTS (3%) HAD STENT GRAFT MIGRATION DURING THE FOLLOW-UP PERIOD: DEVICE MIGRATION REQUIRING A PROXIMAL EXTENSION CUFF (TUBE) IN A TOTAL OF 9 PATIENTS (15.8%). DEVICE MIGRATION WAS REPORTED AS THE CAUSE OF TYPE I ENDOLEAK IN FOUR PATIENTS (ALSO REPORTED UNDER (B)(4)). PLEASE NOTE THAT THE PATIENT QUANTITY FOR PATIENTS WITH DEVICE MIGRATION AS THE CAUSE OF TYPE I ENDOLEAK HAS BEEN COUNTED IN BOTH (B)(4). 26-MAY-23 MFR01.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1296197 UNKNOWN MIH SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT MIH WILLIAM A. COOK AUSTRALIA, PTY LTD UNKNOWN UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 Unknown Required Intervention