FDA Adverse Event Malfunction Summary report: N

CHECK-IT

MDR report key: 16988254 · Received May 23, 2023

Report

Report Number
3016521623-2023-00453
Event Type
Malfunction
Date Received
May 23, 2023
Date of Event
May 10, 2023
Report Date
May 23, 2023
Manufacturer
PFIZER, INC.
Product Code
QJR
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
DC, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

BASED ON INVESTIGATION OF THIS COMPLAINT, NO HARMS REPORTED. PRODUCT HAS NOT BEEN RETURNED. THEREFORE, A DHR REVIEW WAS COMPLETED FOR KIT LOT NUMBER K08A110804223M2 WITH 0 DISCREPANCIES FOUND (ALL LOTS PASSED IN TOTAL PER THE SAMPLING PLAN). A REVIEW OF EXISTING CAPAS, SCARS AND NCMRS WERE COMPLETED AND THERE ARE NO PRIOR RECORDS RELATED TO "FALSE POSITIVE" FAILURE MODE FOR THIS LOT. THERE ARE EIGHT SIMILAR COMPLAINTS ((B)(4), (B)(4), (B)(4), (B)(4), (B)(4), (B)(4), (B)(4) AND (B)(4)) WITH DIFFERENT COMPLAINANTS AND REPORTED ASSOCIATED WITH "FALSE POSITIVE" PRIOR TO REPORTED RECEIPT DATE OF MAY 10, 2023. AN INVESTIGATION INTO THESE SIMILAR COMPLAINTS HAVE BEEN COMPLETED TO OBTAIN ADDITIONAL INFORMATION. DHR REVIEW FOR KIT LOT# K08A110804223M2: SAMPLE VIAL LOT DHR REVIEW: 2202284, 2202439, 2203407, 2203138, 2203139, 2203158, 2203162, 2203222, 2203302, 2203362, 2203303 (ASSOCIATED INTERNAL LOT # 220124-1I, 220124-4E, 220124-4X, 220124-4V, 220124-4W, 220124-4P, 220124-7A, 220124-7E, 220124-7P, 220124-7X, 220124-7W) TEST LOT DHRS REVIEW: 2203616, 2203243, 2203243, 2203243, 2203245, 2203245, 2203245, 2203246, 2203305, 2203304, 2203304, 2203351, 2203351, 2203352, 2203352, 2203400, 2203351, 2203400, 2203401, 2203414 (ASSOCIATED INTERNAL LOT # 220305-30W, 220305-12C, 220305-12B, 220305-12A, 220305-12H, 220305-12G, 220305-12I, 220305-12K, 220305-15I, 220305-15E, 220305-15G, 220305-15W, 220305-15U, 220305-, 5Z, 220305-15Y, 220305-15S, 220305-15V, 220305-18L, 220305-18M, 220305-18R. BASED ON REVIEW OF THE PRODUCT'S FMEAS AND RISK ASSESSMENT DOCUMENTATION, FALSE POSITIVE TEST RESULTS ARE A KNOWN POSSIBLE OUTCOME REGARDING THIS ISSUE UNDER EVALUATION, REFER TO FMEA-001 AND FMEA-004. THE COMPLAINT RATE FOR FALSE POSITIVE IS UNDER THE EXPECTED (B)(4) (INTERNAL WARNING LIMIT). PFIZER WILL CONTINUE TO MONITOR TRENDS RELATED TO FALSE POSITIVE RESULTS IN ACCORDANCE WITH POST-MARKET SURVEILLANCE PROCESS. BASED ON THE LIMITED INFORMATION AVAILABLE, ROOT CAUSE CANNOT BE DETERMINED. WITH ANY POTENTIAL FALSE POSITIVE RESULT, THERE ARE SEVERAL POTENTIAL ROOT CAUSES: LOW VIRAL LOAD IN PATIENT SAMPLE THAT IS BELOW THE LOD OF THE PFIZER AND REFERENCE TEST. AT VIRAL LOADS CLOSE TO LOD A TEST DETECTS A POSITIVE >95% OF THE TIME. WHEN THE VIRAL LOAD IS BELOW LOD, THE FOLLOW-UP TEST CANNOT PICK UP POSITIVE RELIABLY AND CAN GENERATE THE IMPRESSION OF A FALSE POSITIVE RESULT. LOW VIRAL LOADS CAN ALSO RESULT IN SAMPLING VARIABILITY BETWEEN SAMPLES. ENVIRONMENTAL CONTAMINATION FROM OTHER POSITIVES BEING TESTED IN THAT ENVIRONMENT OR DUE TO IMPROPER COLLECTION OR HANDLING OF THE SPECIMEN. DEVICE MALFUNCTION - PLEASE NOTE OUR DEVICES ARE EXTENSIVELY INSPECTED AND TESTED THROUGH A ROBUST LOT RELEASE PROCESS AND THIS SCENARIO IS HIGHLY UNLIKELY. A SUPPLEMENTAL REPORT WILL BE FILED IF ANY FURTHER INVESTIGATION AND/OR ADDITIONAL INFORMATION IS OBTAINED. BASED ON THE COMPLAINT REVIEW, NO HARM WAS REPORTED WITHIN THE COMPLAINT. THIS DEVICE IS MARKETED UNDER (B)(4) CHECK-IT.

Description of Event or Problem · 0

ONE DEVICE REPORTED AS HAVING AN ALLEGED FALSE POSITIVE RESULT. THE COMPLAINANT TOOK 2 ADDITIONAL LUCIRA TESTS AND NUMEROUS ANTIGEN TESTS WITH NEGATIVE RESULTS FOR CONFIRMATION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
257189 CHECK-IT COVID-19 TEST KIT QJR PFIZER, INC. K08A110804223M2

Patients

Seq Age Sex Outcome Treatment
1 Unknown Other