FDA Adverse Event Malfunction Summary report: N

ACCU-CHEK ® AVIVA TEST STRIPS

MDR report key: 1691721 · Received May 17, 2010

Report

Report Number
1823260-2010-02967
Event Type
Malfunction
Date Received
May 17, 2010
Date of Event
May 7, 2010
Report Date
May 25, 2010
Manufacturer
ROCHE DIAGNOSTICS
Product Code
LFR
PMA / PMN Number
K043474
Removal / Correction Number
NA
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
PATIENT

Narratives

Additional Manufacturer Narrative · 1

IT WAS UNKNOWN IF THE INITIAL REPORTER SENT REPORT TO THE FDA.

Description of Event or Problem · 1

IT WAS REPORTED TO US THAT A LAUNCHER 7F (EBU3.75) WAS USED DURING THIS PROCEDURE. MEDTRONIC WAS MADE AWARE OF THIS INFO ON 05/05/2010. THREE ENDEAVOR RESOLUTE RX DRUG-ELUTING STENTS (2.25MM X 14MM, 2.50MM X 14MM, AND 3.50MM X 15MM) (REF MFR REPORT# 2953200-2010-00674, 2953200-2010-00675, 2953200-2010-00676) WERE INSERTED INTO A PT FOR TREATMENT OF A LEFT MAIN AND LAD. A 3.50 X 20 MM SPRINTER LEGEND RX BALLOON DILATATION CATHETER (MFR REPORT#: 2953200-2010-00863), A 4.00MM X 12MM NC SPRINTER RX BALLOON DILATATION CATHETER (MFR REPORT#: 2953200-2010-00864) LESION MORPHOLOGY WAS REPORTED AS SMALL CALCIFIED DIFFUSELY DISEASED CORONARY ARTERIES WITH SIGNIFICANT STENOSIS OF THE LEFT MAIN, PROXIMAL CX AND LAD/ORIGIN DIAGONAL. THE LAD/DIAGONAL WERE DILATED WITH GOBA (BALLOON ONLY). FOLLOWING PRE-DILATATION THE 2.25MM DIAMETER X 14MM LENGTH STENT WAS IMPLANTED AT THE PROXIMAL CX. STENTS WERE IMPLANTED IN THE LEFT MAIN AND ORIGIN LAD, FOLLOWED BY POST DILATATION TO 4 MM. THERE WAS A GOOD ANGIOGRAPHIC RESULT. THE POST OPERATIVE COURSE REPORTED EPISODES OF CHEST PAIN, TROPONIN RISE, HEART FAILURE, AND COLLAPSE AFTER 7 DAYS. IT IS REPORTED THAT THE PT HAD AN EMERGENCY RE-CATHETERIZATION. THE MAIN ARTERIES WERE OPEN BUT NO FILLING OF THE SMALL SIDE BRANCHES WERE OBSERVED. IT IS REPORTED THAT THE PT DIED A WEEK LATER. AN AUTOPSY WAS PERFORMED WHICH SHOWED EXTENSIVE MYOCARDIAL DAMAGE. DEVICES WERE NOT RECEIVED FOR EVAL. SEPARATE MDR'S HAVE BEEN FILED FOR EACH PRODUCT USED IN THIS CASE THEY ARE: ENDEAVOR RESOLUTE-REPORT#2953200-2010-00674 (B) (4), ENDEAVOR RESOLUTE-REPORT#2953200-2010-00675 (B) (4), ENDEAVOR RESOLUTE-REPORT#2953200-2010-00676 , (B) (4), SPRINTER LEGEND RX-REPORT#2953200-2010-00863 (B) (4), NC SPRINTER RX-REPORT#2953200-2010-00864 (B) (4), ZINGER LIGHT SUPPORT 180CM-REPORT# 1220452201000025 (B) (4).

Description of Event or Problem · 1

CALLER REPORTED AVIVA SYSTEM BLOOD GLUCOSE RESULTS OF 175 MG/DL, 192 MG/DL, AND 210 MG/DL, PROFESSIONAL RESULTS OF 101 MG/DL, 101 MG/DL, AND 101 MG/DL WITHIN 10 MINUTES. REPORTED NO ADVERSE EVENT RELATIVE TO DISCREPANCY. STRIPS NOT AVAILABLE FOR RETURN, REPLACEMENT SENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 ACCU-CHEK ® AVIVA TEST STRIPS BLOOD GLUCOSE MONITORING TEST STRIPS LFR ROCHE DIAGNOSTICS NA 302065

Patients

Seq Age Sex Outcome Treatment
1 062 YR GLYBURIDE| LANTUS