FDA Adverse Event Injury Summary report: N

AFFIXUS SCREW TRAUMA IMPL WIN GEN

MDR report key: 16851590 · Received May 2, 2023

Report

Report Number
0009613350-2023-00198
Event Type
Injury
Date Received
May 2, 2023
Date of Event
February 1, 2023
Report Date
May 2, 2023
Manufacturer
ZIMMER SWITZERLAND MANUFACTURING GMBH
Product Code
HSB
PMA / PMN Number
N/A
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

(B)(4). THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL AND/OR CORRECTED INFORMATION. THE FOLLOWING SECTIONS WERE UPDATED: B4, B5, G3, G6, H6, H10. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS.

Additional Manufacturer Narrative · 0

(B)(4). CONCOMITANT MEDICAL PRODUCTS: PROXIMAL HUMERUS, RIGHT, LONG, 8.5X240MM; ITEM#47249624008; LOT#3087021, BLUNT TIP SCREW, 4X40MM; ITEM#47248604040; LOT#3078169, BLUNT TIP SCREW, 4X40MM; ITEM#47248604040; LOT#3082108, TORQUE LIMITING HANDLE, A.5; ITEM#27923; LOT#UNKNOWN. G2- JAPAN. THIS IS THE INITIAL AND FOLLOW-UP COMBINED REPORT. TWO BLUNT TIP SCREWS WERE RETURNED FOR INVESTIGATION. THE OTHER PRODUCTS INVOLVED IN THE REPORTED EVENT WERE NOT RETURNED. THE TWO BLUNT TIP SCREWS WERE VISUALLY INSPECTED AND ON BOTH OF THEM IT IS POSSIBLE TO SEE THAT THE THREADED PARTS ARE PARTIALLY FLATTENED. THE HEADS OF THE BLUNT TIP SCREWS APPEAR INCONSPICUOUS. A REVIEW OF THE DEVICE MANUFACTURING RECORDS (FOR THE NAIL AND 2 BLUNT SCREWS) CONFIRMED NO ABNORMALITIES OR DEVIATIONS. THE REVIEW OF THE DEVICE MANUFACTURING RECORDS FOR THE UNKNOWN SCREW COULD NOT BE PERFORMED. DEVICES USED FOR TREATMENT. X-RAY IMAGES OF THE AFFECTED HUMERUS ARE AVAILABLE. THE X-RAYS WERE REVIEWED BY A RADIOLOGIST: TWO VIEWS OF THE RIGHT HUMERUS PROXIMALLY DEMONSTRATE AN INTRAMEDULLARY ROD WITH OBLIQUE FRACTURE LINE STILL SEEN ALONG THE PROXIMAL TO MID HUMERAL DIAPHYSIS. THREE PROXIMAL INTERLOCKING SCREWS ARE PRESENT, ALL OF WHICH APPEAR TO HAVE BACKED OUT SOMEWHAT MOST PROMINENTLY INVOLVING THE MOST PROXIMAL SCREW. NO SURGICAL REPORTS WERE PROVIDED. BASED ON THE INVESTIGATION IT COULD BE ASSUMED THAT FURTHER POSSIBLE CONTRIBUTING FACTORS TO THE MIGRATION OF THE SCREW MIGHT BE MULTIFACTORIAL RELATED TO EITHER PATIENT CONDITION, BEHAVIOR OR IMPLANTATION PROCEDURE. IF AND TO WHAT EXTENT ANY OF THESE ASPECTS MAY HAVE INFLUENCED THE MIGRATION OF THE SCREW REMAINS UNKNOWN. AN ADDITIONAL DEEPER INVESTIGATION WAS PERFORMED WHICH IDENTIFIED THE DESIGN LIMITATION OF THE CORELOCK MECHANISM OF THE AFFIXUS NAIL AS A POTENTIAL CONTRIBUTING FACTOR. AS PART OF THE DEEPER INVESTIGATION, A SCIENTIFIC LITERATURE SEARCH WAS CONDUCTED AND A SYSTEMATIC REVIEW OF THE OUTCOME OF INTRAMEDULLARY NAILING FOR ACUTE PROXIMAL HUMERUS FRACTURE SHOWED THAT SCREW MIGRATION AND PERFORATION INTO THE JOINT IS THE SECOND MOST COMMON COMPLICATION FOLLOWING SECONDARY LOSS OF REDUCTION. IN ADDITION, SCIENTIFIC LITERATURE OF COMPETITOR AND PREDICATE DEVICES WERE ASSESSED. THIS REVIEW HAS SHOWN THAT THE AFFIXUS NATURAL NAIL PROXIMAL HUMERAL SYSTEM PERFORMS BETTER AND/OR IN EQUAL RANGE IN COMPARISON WITH LEGALLY MARKETED SIMILAR DEVICES. IN CONCLUSION, AS THE CAUSE MAY BE MULTIFACTORIAL AN EXACT ROOT CAUSE COULD NOT BE IDENTIFIED FOR THE MIGRATION OF THE SCREW. MULTIPLE MDR REPORTS WERE FILED FOR THIS EVENT, PLEASE SEE THE ASSOCIATED REPORTS: 0009613350 - 2023 - 00083, 0009613350 - 2023 - 00086, 0009613350 - 2023 - 00089. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS. LOT/ITEM UNKNOWN.

Description of Event or Problem · 0

NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE PATIENT UNDERWENT REVISION SURGERY DUE TO MIGRATION. APPROXIMATELY ONE AND HALF MONTHS POST-OP. ATTEMPTS HAVE BEEN MADE AND ALL ADDITIONAL INFORMATION RECEIVED HAS BEEN INCLUDED IN THIS REPORT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1635890 AFFIXUS SCREW TRAUMA IMPL WIN GEN ROD, FIXATION, INTRAMEDULLARY HSB ZIMMER SWITZERLAND MANUFACTURING GMBH UNKNOWN UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 Prefer Not To Disclose Required Intervention| H SEE H10 NARRATIVE