DAVINCI SI
Report
- Report Number
- 2955842-2023-12082
- Event Type
- Injury
- Date Received
- April 20, 2023
- Date of Event
- March 28, 2023
- Report Date
- March 28, 2023
- Manufacturer
- INTUITIVE SURGICAL, INC
- Product Code
- NAY
- UDI-DI
- 00886874110690
- PMA / PMN Number
- K081137
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TW
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
BASED ON THE CURRENT INFORMATION PROVIDED, THE CAUSE OF THE POST-OPERATIVE COMPLICATIONS CANNOT BE DETERMINED. THERE WAS NO CLAIM AGAINST THE PRODUCT AND NO INDICATION OF A PRODUCT ISSUE, AND THUS THERE IS NO INDICATION THAT THE DEVICE DIRECTLY CAUSED THE REPORTED EVENT. A FOLLOW-UP MDR WILL BE SUBMITTED IF ADDITIONAL INFORMATION IS RECEIVED. A SYSTEM LOG CANNOT BE PERFORMED BECAUSE THE SYSTEM LOGS ARE NOT AVAILABLE AT THIS TIME AS THERE WAS INSUFFICIENT INFORMATION. THIS COMPLAINT IS CONSIDERED A REPORTABLE EVENT DUE TO THE FOLLOWING CONCLUSION: INTUITIVE SURGICAL BECAME AWARE OF A JOURNAL OF PLASTIC, RECONSTRUCTIVE & AESTHETIC SURGERY ARTICLE, AND IT WAS MENTIONED THERE WERE 22 POST-OPERATIVE COMPLICATIONS IN 54 PATIENTS THAT UNDERWENT ROBOTIC NIPPLE SPARING MASTECTOMIES (NSM). ACCORDING TO THE LITERATURE AUTHOR, OF THE 22 POST-OPERATIVE COMPLICATIONS, 13 OF THEM WERE SIGNIFICANT.
ON 28-MAR-2023, INTUITIVE SURGICAL, INC. (ISI) BECAME AWARE OF A JOURNAL OF PLASTIC, RECONSTRUCTIVE & AESTHETIC SURGERY ARTICLE TITLED, ¿ROBOTIC VERSUS CONVENTIONAL NIPPLE SPARING MASTECTOMY AND IMMEDIATE GEL IMPLANT BREAST RECONSTRUCTION IN THE MANAGEMENT OF BREAST CANCER- A CASE CONTROL COMPARISON STUDY WITH ANALYSIS OF CLINICAL OUTCOME, MEDICAL COST, AND PATIENT-REPORTED COSMETIC RESULTS¿ (LAI, H.W., ET AL., 2020). WITHIN THE JOURNAL ARTICLE, POST-OPERATIVE COMPLICATIONS INVOLVING DA VINCI-ASSISTED NIPPLE SPARING MASTECTOMIES (NSM) WITH IMMEDIATE GEL IMPLANT BREAST RECONSTRUCTION FROM JULY 2011 TO SEPTEMBER 2019 WERE NOTED. A TOTAL OF 22 POST-OPERATIVE COMPLICATIONS WERE REPORTED IN 54 PATIENTS THAT UNDERWENT ROBOTIC NSM. THE POST-OPERATIVE COMPLICATIONS WERE AS FOLLOWS: 5 PATIENTS HAD DELAYED WOUND HEALING, 6 PATIENTS HAD TRANSIENT PARTIAL NIPPLE ISCHEMIA, 1 PATIENT HAD PARTIAL NIPPLE AREOLAR COMPLEX NECROSIS, 3 PATIENTS HAD SEROMA FORMATION THAT NEEDED ASPIRATION, 1 PATIENT HAD BLISTER FORMATION, 5 PATIENTS HAD SKIN FLAP SMALL PARTIAL ISCHEMIA NECROSIS, 1 PATIENT HAD HEMATOMA FORMATION. OF THE 22 POST-OPERATIVE COMPLICATIONS, 13 OF THEM WERE SIGNIFICANT, ACCORDING TO THE LITERATURE AUTHOR. THE NON-SIGNIFICANT COMPLICATIONS WERE DEFINED AS TRANSIENT NIPPLE ISCHEMIA, WHICH RECOVERED AFTER CONSERVATIVE MANAGEMENT, AND SEROMA WHICH WAS RELIEVED AFTER REPEATED ASPIRATIONS. ALL THE PATIENTS HAD OPERABLE BREAST CANCER, AND THE DA-VINCI ASSISTED NIPPLE SPARING MASTECTOMIES WERE PERFORMED BY THE SAME SURGEON AT A SINGLE INSTITUTION. INTUITIVE SURGICAL, INC, (ISI) MADE MULTIPLE ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION. HOWEVER, AT THE TIME OF THIS REPORT, NO ADDITIONAL INFORMATION HAS BEEN RECEIVED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1613411 | DAVINCI SI | PATIENT SIDE CART, 4-ARM | NAY | INTUITIVE SURGICAL, INC | 380614-10 | N/A | 00886874110690 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Female | DA VINCI INSTRUMENTS AND ACCESSORIES |