UNKNOWN PARIETEX PRODUCT
Report
- Report Number
- 9615742-2023-00466
- Event Type
- Injury
- Date Received
- April 4, 2023
- Date of Event
- June 20, 2022
- Report Date
- April 4, 2023
- Manufacturer
- SOFRADIM PRODUCTION SAS
- Product Code
- FTL
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KS
- Reporter Occupation
- OTHER
Narratives
TITLE: LEARNING CURVE ANALYSIS USING THE CUMULATIVE SUMMATION METHOD FOR TOTALLY EXTRAPERITONEAL REPAIR OF THE INGUINAL HERNIA SOURCE: LANGENBECK'S ARCHIVES OF SURGERY (2022) 407:3101¿3106 PUBLISHED DATE: 23 JUNE 2022. MEDTRONIC IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ¿DEFECTS¿ OR HAS ¿MALFUNCTIONED¿. THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REGULATORY REPORTING. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE THEM BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
ACCORDING TO THE LITERATURE SOURCE OF STUDY PERFORMED BETWEEN APRIL 2017 AND JULY 2019, A RETROSPECTIVE STUDY ANALYZED THE LEARNING CURVE ANALYSIS USING THE CUMULATIVE SUMMATION METHOD FOR TOTALLY EXTRAPERITONEAL REPAIR OF THE INGUINAL HERNIA. THERE WERE A TOTAL OF 328 PATIENTS INCLUDED IN THE STUDY. AFTER COMPLETE LATERALIZATION OR PARALLELIZATION OF THE CORD STRUCTURES, POLYESTER ANATOMICAL MESH WAS PLACED ON THE PREPERITONEAL SPACE. POST OPERATIVE COMPLICATIONS INCLUDE HERNIA RECURRENCE. NO INTERVENTIONS WERE REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 404656 | UNKNOWN PARIETEX PRODUCT | MESH, SURGICAL, POLYMERIC | FTL | SOFRADIM PRODUCTION SAS | UNKNOWN PARIETEX PRODUCT |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown | Required Intervention |