FDA Adverse Event Injury Summary report: N

UNKNOWN RETRACTOR

MDR report key: 16628316 · Received March 28, 2023

Report

Report Number
1038671-2023-00521
Event Type
Injury
Date Received
March 28, 2023
Date of Event
February 17, 2023
Report Date
May 18, 2026
Manufacturer
EXACTECH, INC.
Product Code
KWT
PMA / PMN Number
UNK
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

SECTION H10: (H3) UPON REVIEW, THERE IS NO INDICATION THAT THERE IS A DEVICE RELATED PROBLEM, THERE IS NO ALLEGATION AGAINST THE DEVICE. THE MOST LIKELY CAUSE OF THE REPORTED EVENT IS RELATED TO THE UNDERLYING PATIENT CONDITION. SECTION H11: *THE FOLLOWING SECTIONS HAVE CORRECTED INFORMATION: (B5) DESCRIBE EVENT OR PROBLEM: IT WAS REPORTED VIA CLINICAL STUDY, THAT THE 78 YO MALE PATIENT HAS AVN (AVASCULAR NECROSIS) WITH SOFT BONE AND WHILE RETRACTING FOR GLENOID EXPOSURE THE GREATER TUBEROSITY FRACTURED. THE DATE OF ADVERSE EVENT ONSET IS 02-17-2023. THE ACTIONS TAKEN WAS THE USE OF STANDARD STEM AND FIBER WIRE THROUGH TUBEROSITY. THE PATIENT WAS REVISED BY REMOVAL OF COMPONENTS. THE PATIENT¿S OUTCOME WAS LAST KNOWN AS CONTINUING. THE CASE REPORT FORM INDICATES THIS EVENT IS DEFINITELY NOT RELATED TO DEVICE AND DEFINITELY NOT RELATED TO PROCEDURE. (D1) BRAND NAME: SHOULDER COMPONENTS.

Description of Event or Problem · 0

IT WAS REPORTED VIA CLINICAL STUDY, THAT THE 78 YO MALE PATIENT HAS AVN (AVASCULAR NECROSIS) WITH SOFT BONE AND WHILE RETRACTING FOR GLENOID EXPOSURE THE GREATER TUBEROSITY FRACTURED. THE DATE OF ADVERSE EVENT ONSET IS 02-17-2023. THE ACTIONS TAKEN WAS THE USE OF STANDARD STEM AND FIBER WIRE THROUGH TUBEROSITY. THE PATIENT WAS REVISED BY REMOVAL OF COMPONENTS. THE PATIENT¿S OUTCOME WAS LAST KNOWN AS CONTINUING. THE CASE REPORT FORM INDICATES THIS EVENT IS DEFINITELY NOT RELATED TO DEVICE AND DEFINITELY NOT RELATED TO PROCEDURE.

Description of Event or Problem · 0

IT WAS REPORTED VIA CLINICAL STUDY, THAT THE 78 YO MALE PATIENT HAS AVN (AVASCULAR NECROSIS) WITH SOFT BONE AND WHILE RETRACTING FOR GLENOID EXPOSURE THE GREATER TUBEROSITY FRACTURED. THE DATE OF ADVERSE EVENT ONSET IS (B)(6) 2023. THE ACTIONS TAKEN WAS THE USE OF STANDARD STEM AND FIBER WIRE THROUGH TUBEROSITY. THE PATIENT WAS REVISED BY REMOVAL OF COMPONENTS. THE PATIENT¿S OUTCOME WAS LAST KNOWN AS CONTINUING.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
610679 UNKNOWN RETRACTOR PROSTHESIS, SHOULDER, NON-CONSTRAINED, METAL/POLYMER CEMENTED KWT EXACTECH, INC. UNK UNK

Patients

Seq Age Sex Outcome Treatment
1