FDA Adverse Event Malfunction Summary report: N

HGLISS GW, MED, J 190-014

MDR report key: 16597918 · Received March 23, 2023

Report

Report Number
3006010712-2023-00013
Event Type
Malfunction
Date Received
March 23, 2023
Date of Event
March 2, 2023
Report Date
May 16, 2023
Manufacturer
LAKE REGION MEDICAL
Product Code
DQX
PMA / PMN Number
K141831
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FR
Reporter Occupation
501

Narratives

Additional Manufacturer Narrative · 0

COMPLAINT INVESTIGATION IS ATTACHED TO THIS REPORT.

Additional Manufacturer Narrative · 0

COMPLAINT INVESTIGATION UNDERWAY AND WILL BE ATTACHED TO THIS REPORT.

Description of Event or Problem · 0

LAST (B)(6) 2023, AT A CRTD IMPLANT PROCEDURE, THE DR. (B)(6), WHO HAS AN IMPORTANT EXPERIENCE WITH OUR DEVICES, IMPLANTED A GALI 4LV SN: (B)(6). FOR IMPLANT LV LEAD, FIRST OPTION WAS A QUARTET 1458Q-86 WITH SN: (B)(6) AND A HYDROGLISS J SOFT LOT: 5699362 WELL WASHED WITH HEPARINIZED SERUM. THIS GUIDEWIRE HAD VERY PROBLEMS TO PROGRESS INTO THE LEAD AND THE DR. AL RAZZO WANTED RETRIEVE IT APPLYING A LOT OF FORCE. AFTER HE USED THE HYDROGLISS J MEDIUM LOT: 5699363 (WELL WASHED WITH HEPARINIZED SERUM) AND HE GOT THE SAME RESULT BUT HE COULD NOT RETRIEVE THE HYDROGLISS (ATTACHED). AFTER WE CHANGE THE LV LEAD TO A QUARTET 1456Q-86 SN: (B)(6) AND HE USED THE HYDROGLISS J SOFT LOT: 5699362 AND HE COULD NOT PROGRESS THE GUIDEWIRE CORRECTLY. HE HAD TO APPLY MORE FORCE THAN NORMAL. HE COULD RETRIVE THE GUIDEWIRE APPLYING A LOT OF FORCE AND THE LEAD TWISTED. HE COULD IMPLANT THE LEAD WITH A 0.014" GUIDEWIRE BY ST JUDE WITHOUT PROBLEMS BUT WHEN WE DID THE ELECTRICAL MEASUREMENTS WITH THE PSA THE IMPEDANCE WAS <200 OHMS. SO I RECOMMENDED CHANGE THE LV LEAD TO A NEW QUARTET 1458Q-86 SN: (B)(6). IT WAS IMPLANTED WITHOUT PROBLEMS WITH A 0,014" GUIDEWIRE BY ST JUDE MEDICAL.

Description of Event or Problem · 0

LAST (B)(6), 2023, AT A CRTD IMPLANT PROCEDURE, THE DR. (B)(6), WHO HAS AN IMPORTANT EXPERIENCE WITH OUR DEVICES, IMPLANTED A GALI 4LV SN: (B)(4). FOR IMPLANT LV LEAD, FIRST OPTION WAS A QUARTET 1458Q-86 WITH SN: (B)(4) AND A HYDROGLISS J SOFT LOT: 5699362 WELL WASHED WITH HEPARINIZED SERUM. THIS GUIDEWIRE HAD VERY PROBLEMS TO PROGRESS INTO THE LEAD AND THE DR. (B)(6) WANTED RETRIEVE IT APPLYING A LOT OF FORCE. AFTER HE USED THE HYDROGLISS J MEDIUM LOT: 5699363 (WELL WASHED WITH HEPARINIZED SERUM) AND HE GOT THE SAME RESULT BUT HE COULD NOT RETRIEVE THE HYDROGLISS (ATTACHED). AFTER WE CHANGE THE LV LEAD TO A QUARTET 1456Q-86 SN: (B)(4) AND HE USED THE HYDROGLISS J SOFT LOT: 5699362 AND HE COULD NOT PROGRESS THE GUIDEWIRE CORRECTLY. HE HAD TO APPLY MORE FORCE THAN NORMAL. HE COULD RETRIVE THE GUIDEWIRE APPLYING A LOT OF FORCE AND THE LEAD TWISTED. HE COULD IMPLANT THE LEAD WITH A 0.014" GUIDEWIRE BY ST JUDE WITHOUT PROBLEMS BUT WHEN WE DID THE ELECTRICAL MESUREMENTS WITH THE PSA THE IMPEDANCE WAS <200 OHMS. SO I RECOMMENDED CHAGE THE LV LEAD TO A NEW QUARTET 1458Q-86 SN: (B)(4). IT WAS IMPLANTED WITHOUT PROBLEMS WITH A 0,014" GUIDEWIRE BY (B)(6) MEDICAL.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
10808 HGLISS GW, MED, J 190-014 HGLISS GW, MED, J 190-014 DQX LAKE REGION MEDICAL 901053-05 5699363

Patients

Seq Age Sex Outcome Treatment
1 Unknown