FDA Adverse Event Injury Summary report: N

UNKNOWN POLYSORB SUTURE

MDR report key: 16574444 · Received March 20, 2023

Report

Report Number
9612501-2023-00468
Event Type
Injury
Date Received
March 20, 2023
Date of Event
March 11, 2022
Report Date
March 20, 2023
Manufacturer
DAVIS & GECK CARIBE LTD
Product Code
GAM
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
EI
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

TITLE: LAPAROSCOPIC PAEDIATRIC INGUINAL HERNIA REPAIR: LESSONS LEARNED FROM 102 CASES SOURCE: IRISH JOURNAL OF MEDICAL SCIENCE (1971 -) (2023) 192:321¿326 PUBLISHED ONLINE: 22 MARCH 2022. CONCOMITANT MEDICAL PRODUCTS: UNKNOWN - SPRO, UNKNOWN SURGIPRO (LOT#UNK). MEDTRONIC IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MEDTRONIC, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MEDTRONIC HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE AN ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY ¿DEFECTS¿ OR HAS ¿MALFUNCTIONED¿. THESE WORDS ARE INCLUDED IN THE FDA 3500A FORM AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REGULATORY REPORTING. MEDTRONIC OBJECTS TO THE USE OF THESE WORDS AND OTHERS LIKE THEM BECAUSE OF THE LACK OF DEFINITION AND THE CONNOTATIONS IMPLIED BY THESE TERMS. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 0

ACCORDING TO THE LITERATURE SOURCE OF STUDY PERFORMED BETWEEN JANUARY 2018 AND NOVEMBER 2020, A RETROSPECTIVE STUDY EVALUATED OUTCOMES IN PEDIATRIC PATIENTS WHO UNDERWENT LAPAROSCOPIC INGUINAL HERNIA REPAIR. POLYSORB (4-0) WAS USED TO CLOSE THE FASCIA AFTER THE UMBILICAL PORT WAS REMOVED. POSTOPERATIVE COMPLICATIONS INCLUDED: PORT-SITE HEMATOMA AND PORT-SITE HERNIA. HEMATOMA WAS RESOLVED WITH CONSERVATIVE TREATMENT. SURGICAL REPAIR WAS REQUIRED TO TREAT PORT-SITE HERNIA. COMPLICATIONS OF RECURRENT HERNIA WAS RELATED TO THE USE OF DIATHERMY AND NOT RELATED TO SURGIPRO SUTURE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
893001 UNKNOWN POLYSORB SUTURE SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC AC GAM DAVIS & GECK CARIBE LTD UNKNOWN POLYSORB SUTURE

Patients

Seq Age Sex Outcome Treatment
1 Unknown Required Intervention