UNKNOWN VICRYL RAPIDE SUTURE
Report
- Report Number
- 2210968-2023-01786
- Event Type
- Injury
- Date Received
- March 20, 2023
- Date of Event
- January 1, 2018
- Report Date
- March 20, 2023
- Manufacturer
- ETHICON INC.
- Product Code
- GAM
- PMA / PMN Number
- K033746
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CH
- Reporter Occupation
- OTHER
Narratives
(B)(4). THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON INC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. COMPONENT CODE: G07002 ¿ DEVICE NOT RETURNED. THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS. THERE ARE NO ADDITIONAL DETAILS REGARDING THE ADDITIONAL EVENTS. CITATION: CHINESE JOURNAL OF TISSUE ENGINEERING RESEARCH, 2018, 22 (35): 5607-5613. HTTPS://DOI.ORG/10.3969/J.ISSN.2095-4344.1006.
TITLE: EFFICACY OF ADJUSTABLE EXTERNAL SUPPORT VERSUS HINGED EXTERNAL FIXATOR IN THE TREATMENT OF TERRIBLE TRIAD OF ELBOW. THE AIM OF THIS RETROSPECTIVE COHORT STUDY WAS TO COMPARE THE EFFICACY OF HINGED EXTERNAL FIXATOR AND EXTERNAL FIXATOR IN THE TREATMENT OF TERRIBLE TRIAD OF ELBOW JOINT. BETWEEN JANUARY 2013 TO JANUARY 2017, A TOTAL OF 65 PATIENTS (29 MALES AND 36 FEMALES; AVERAGE AGE OF 35.1 ± 8.1 YEARS) WITH THE "TERRIBLE TRIAD OF THE ELBOW" ADMITTED IN THE ZHUJIANG HOSPITAL OF SOUTHERN MEDICAL UNIVERSITY WERE INCLUDED IN THE STUDY. THE COLLATERAL OPERATION WAS PERFORMED COMBINED WITH LATERAL AND MEDIAL SURGERY APPROACHES OF THE ELBOW JOINT FOR THE OPEN REDUCTION AND FIXATION OF THE CAPITULUM RADIAL AND CORONOID FRACTURE, AND REPAIR OF THE LIGAMENT. A VICRYL RAPIDE ABSORBABLE SUTURE, JOHNSON & JOHNSON MEDICAL EQUIPMENT CO., LTD., BATCH NUMBER: 3650766 WAS USED DURING SURGERY. ACCORDING TO EXTERNAL FIXATION AFTER SURGERY, PATIENTS WERE DIVIDED INTO TWO GROUPS. SUPPORT GROUP: 30 PATIENTS WERE TREATED WITH ADJUSTABLE EXTERNAL SUPPORT AFTER SURGERY. FIXATOR GROUP: 35 PATIENTS RECEIVED HINGED EXTERNAL FIXATOR AFTER SURGERY. REPORTED COMPLICATIONS INCLUDE HETEROTOPIC OSSIFICATION OF THE ELBOW (N=3) AND ARTICULAR VALGUS DEFORMITY HEALING (N=1). IN CONCLUSION, ADJUSTABLE EXTERNAL SUPPORT AND HINGED EXTERNAL FIXATOR HAVE THE SAME EFFECT ON ELBOW JOINT FLEXION AND EXTENSION ACTIVITY, RANGE OF FOREARM ROTATION, HEALING TIME AND MAYO SCORE, AND ADJUSTABLE EXTERNAL SUPPORT CAN REPLACE HINGED EXTERNAL FIXATOR UNDER CERTAIN CONDITIONS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 8480 | UNKNOWN VICRYL RAPIDE SUTURE | SUTURE, ABSORBABLE, SYNTHETIC | GAM | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown | Other |