FLOTRAC SENSOR
Report
- Report Number
- 2015691-2023-11507
- Event Type
- Malfunction
- Date Received
- March 16, 2023
- Report Date
- March 16, 2023
- Manufacturer
- EDWARDS LIFESCIENCES DR
- Product Code
- DRS
- PMA / PMN Number
- K043065
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
THE DEVICE WAS NOT RETURNED FOR EVALUATION. WITHOUT RETURN OF THE UNIT IT IS NOT POSSIBLE TO DETERMINE IF SOME DAMAGE OR DEFECT EXISTED ON THE UNIT THAT COULD HAVE CONTRIBUTED TO THE EVENT. IT IS NOT KNOWN IF SOME PROCEDURAL FACTORS MAY HAVE CONTRIBUTED TO THE EVENT. FURTHER EVALUATION REGARDING RELATED QUALITY ISSUES IS UNDER INVESTIGATION. THE LOT NUMBER WAS NOT PROVIDED THUS A DEVICE HISTORY RECORD WAS NOT REVIEWED. COMPLAINT HISTORIES FOR ALL REPORTED EVENTS ARE REVIEWED AGAINST TRENDING CONTROL LIMITS ON A MONTHLY BASIS AND ANY EXCURSIONS ABOVE THE CONTROL LIMITS ARE ASSESSED AND DOCUMENTED AS A PART OF THE MONTHLY REVIEW.
THE FOLLOWING INFORMATION WAS OBTAINED THROUGH A LITERATURE PUBLISHED IN SCIENTIFIC REPORTS, AGREEMENT BETWEEN CONTINUOUS CARDIAC OUTPUT MEASURED BY THE FOURTH GENERATION FLOTRAC VIGILEO SYSTEM AND A PULMONARY ARTERY CATHETER IN ADULT LIVER TRANSPLANTATION. IN LIVER TRANSPLANTATION FOR END STAGE LIVER FAILURE, MONITORING OF CONTINUOUS CARDIAC OUTPUT, CCO IS USED FOR CIRCULATORY MANAGEMENT DUE TO HEMODYNAMIC INSTABILITY. CCO IS OFTEN MEASURED USING THE MINIMALLY INVASIVE FLOTRAC VIGILEO SYSTEM, FVS CCO, INSTEAD OF A HIGHLY INVASIVE PULMONARY ARTERY CATHETER, PAC CCO. THE FVS HAS IMPROVED ACCURACY DUE TO AN UPDATED CARDIAC OUTPUT ALGORITHM, BUT THE EFFECT OF THIS CHANGE ON THE ACCURACY OF FVS CCO IN LIVER TRANSPLANTATION IS UNCLEAR. IN THIS STUDY, WE ASSESSED AGREEMENT BETWEEN FOURTH GENERATION FVS CCO AND PAC CCO IN 20 PATIENTS AGED GREATER OR EQUAL TO 20 YEARS WHO UNDERWENT SCHEDULED OR EMERGENCY LIVER TRANSPLANTATION AT KYOTO UNIVERSITY HOSPITAL FROM SEPTEMBER 2019 TO JUNE 2021. CONSENT WAS OBTAINED BEFORE SURGERY AND DATA WERE RECORDED THROUGHOUT THE SURGICAL PERIOD. PEARSON CORRELATION COEFFICIENT, R, BLAND ALTMAN AND 4 QUADRANT PLOT ANALYSES WERE PERFORMED ON THE EXTRACTED DATA. A TOTAL OF 1517 PAC CCO VS. FVSCCO DATA PAIRS WERE OBTAINED. THE MEAN PAC CCO WAS 8.73 L OVER MIN, AND THE MEAN SYSTEMIC VASCULAR RESISTANCE WAS 617.5 DYNE S CM5, R WAS 0.48, BIAS WAS 1.62 L OVER MIN, THE 95 PERCENTAGE LIMITS OF AGREEMENT WERE NEGATIVE 3.04 TO 6.27, AND THE PERCENTAGE ERROR WAS 54.36 PERCENT. THESE RESULTS SHOW THAT AGREEMENT AND TRENDING BETWEEN FOURTH GENERATION FVS CCO AND PAC CCO ARE LOW IN ADULT LIVER TRANSPLANT RECIPIENTS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 437374 | FLOTRAC SENSOR | TRANSDUCER, BLOOD-PRESSURE, EXTRAVASCULAR | DRS | EDWARDS LIFESCIENCES DR | FLOTRACUNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Unknown |