BLUNT TIP SCREW, 4X40MM
Report
- Report Number
- 0009613350-2023-00086
- Event Type
- Injury
- Date Received
- February 27, 2023
- Date of Event
- February 1, 2023
- Report Date
- May 2, 2023
- Manufacturer
- ZIMMER SWITZERLAND MANUFACTURING GMBH
- Product Code
- HSB
- UDI-DI
- 00889024505445
- PMA / PMN Number
- K181827
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
(B)(4). PROXIMAL HUMERUS, RIGHT, LONG, 8.5X240MM; ITEM#47249624008; LOT#3087021. BLUNT TIP SCREW, 4X40MM; ITEM#47248604040; LOT#3082108. AFFIXUS SCREW TRAUMA IMPL WIN GEN; ITEM#UNKNOWN; LOT#UNKNOWN. TORQUE LIMITING HANDLE, A.5; ITEM#27923; LOT#UNKNOWN. THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL AND/OR CORRECTED INFORMATION. TWO BLUNT TIP SCREWS WERE RETURNED FOR INVESTIGATION. THE OTHER PRODUCTS INVOLVED IN THE REPORTED EVENT WERE NOT RETURNED. THE TWO BLUNT TIP SCREWS WERE VISUALLY INSPECTED AND ON BOTH OF THEM IT IS POSSIBLE TO SEE THAT THE THREADED PARTS ARE PARTIALLY FLATTENED. THE HEADS OF THE BLUNT TIP SCREWS APPEAR INCONSPICUOUS. A REVIEW OF THE DEVICE MANUFACTURING RECORDS (FOR THE NAIL AND 2 BLUNT SCREWS) CONFIRMED NO ABNORMALITIES OR DEVIATIONS. THE REVIEW OF THE DEVICE MANUFACTURING RECORDS FOR THE UNKNOWN SCREW COULD NOT BE PERFORMED. DEVICES USED FOR TREATMENT. X-RAY IMAGES OF THE AFFECTED HUMERUS ARE AVAILABLE. THE X-RAYS WERE REVIEWED BY A RADIOLOGIST: TWO VIEWS OF THE RIGHT HUMERUS PROXIMALLY DEMONSTRATE AN INTRAMEDULLARY ROD WITH OBLIQUE FRACTURE LINE STILL SEEN ALONG THE PROXIMAL TO MID HUMERAL DIAPHYSIS. THREE PROXIMAL INTERLOCKING SCREWS ARE PRESENT, ALL OF WHICH APPEAR TO HAVE BACKED OUT SOMEWHAT MOST PROMINENTLY INVOLVING THE MOST PROXIMAL SCREW. NO SURGICAL REPORTS WERE PROVIDED. BASED ON THE INVESTIGATION IT COULD BE ASSUMED THAT FURTHER POSSIBLE CONTRIBUTING FACTORS TO THE MIGRATION OF THE SCREW MIGHT BE MULTIFACTORIAL RELATED TO EITHER PATIENT CONDITION, BEHAVIOR OR IMPLANTATION PROCEDURE. IF AND TO WHAT EXTENT ANY OF THESE ASPECTS MAY HAVE INFLUENCED THE MIGRATION OF THE SCREW REMAINS UNKNOWN. AN ADDITIONAL DEEPER INVESTIGATION WAS PERFORMED WHICH IDENTIFIED THE DESIGN LIMITATION OF THE CORELOCK MECHANISM OF THE AFFIXUS NAIL AS A POTENTIAL CONTRIBUTING FACTOR. AS PART OF THE DEEPER INVESTIGATION, A SCIENTIFIC LITERATURE SEARCH WAS CONDUCTED AND A SYSTEMATIC REVIEW OF THE OUTCOME OF INTRAMEDULLARY NAILING FOR ACUTE PROXIMAL HUMERUS FRACTURE SHOWED THAT SCREW MIGRATION AND PERFORATION INTO THE JOINT IS THE SECOND MOST COMMON COMPLICATION FOLLOWING SECONDARY LOSS OF REDUCTION. IN ADDITION, SCIENTIFIC LITERATURE OF COMPETITOR AND PREDICATE DEVICES WERE ASSESSED. THIS REVIEW HAS SHOWN THAT THE AFFIXUS NATURAL NAIL PROXIMAL HUMERAL SYSTEM PERFORMS BETTER AND/OR IN EQUAL RANGE IN COMPARISON WITH LEGALLY MARKETED SIMILAR DEVICES. IN CONCLUSION, AS THE CAUSE MAY BE MULTIFACTORIAL AN EXACT ROOT CAUSE COULD NOT BE IDENTIFIED FOR THE MIGRATION OF THE SCREW. MULTIPLE MDR REPORTS WERE FILED FOR THIS EVENT, PLEASE SEE THE ASSOCIATED REPORTS: 0009613350 - 2023 - 00083; 0009613350 - 2023 - 00089; 0009613350 - 2023 - 00198. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS.
CMP-(B)(4). PROXIMAL HUMERUS, RIGHT, LONG, 8.5X240MM; ITEM#47249624008; LOT#3087021 BLUNT TIP SCREW, 4X40MM; ITEM#47248604040; LOT#3082108 TORQUE LIMITING HANDLE, A.5; ITEM#27923; LOT#UNKNOWN. FOREIGN COUNTRY- (B)(6). THE DEVICE WILL NOT BE RETURNED FOR ANALYSIS; HOWEVER, AN INVESTIGATION OF THE REPORTED EVENT IS IN PROGRESS. ONCE THE INVESTIGATION IS COMPLETED, A SUPPLEMENTAL MEDWATCH 3500A WILL BE SUBMITTED. MULTIPLE MDR REPORTS WERE FILED FOR THIS EVENT, PLEASE SEE THE ASSOCIATED REPORTS: 0009613350 - 2023 - 00083; 0009613350 - 2023 - 00086; 0009613350 - 2023 - 00089.
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
IT WAS REPORTED THAT THE PATIENT UNDERWENT REVISION SURGERY DUE TO MIGRATION. APPROXIMATELY ONE AND HALF MONTHS POST-OP. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 800290 | BLUNT TIP SCREW, 4X40MM | ROD, FIXATION, INTRAMEDULLARY | HSB | ZIMMER SWITZERLAND MANUFACTURING GMBH | N/A | 3078169 | 00889024505445 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Prefer Not To Disclose | Hospitalization| R |