FDA Adverse Event Malfunction Summary report: N

RELION INSULIN SYRINGE 3/10ML 29G X 8MM

MDR report key: 16412270 · Received February 21, 2023

Report

Report Number
1920898-2023-00060
Event Type
Malfunction
Date Received
February 21, 2023
Date of Event
January 26, 2023
Report Date
June 9, 2023
Manufacturer
BD MEDICAL - DIABETES CARE
Product Code
FMF
UDI-DI
00681131311786
PMA / PMN Number
K212499
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NC, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: D10: DEVICE AVAILABLE FOR EVAL YES, D10: RETURNED TO MANUFACTURER ON: 24-FEB-2023. H6: INVESTIGATION SUMMARY CUSTOMER RETURNED (4) SYRINGE 0.3ML 31GA 8MM IN AN OPEN POLY BAG FROM LOT# 2213837. IT WAS REPORTED BY THE CONSUMER THAT LIQUID COMES OUT FROM SYRINGE WHEN DEPRESSING PLUNGER ROD. THE 4 RETURN SAMPLES FROM THE OPEN POLY BAG WERE TESTED AND SMALL CLEAR DROPLET OF MATERIAL CAME OUT OF THE CANNULA ONLY FOR ONE SYRINGE. A SMALL PORTION OF THIS MATERIAL WAS REMOVED FROM THE SAMPLE AND PREPARED FOR FTIR SPECTRAL ANALYSIS. THE SPECTRAL ANALYSIS SHOWS THAT THIS MATERIAL IS MOST LIKELY SILICONE. A REVIEW OF THE DEVICE HISTORY RECORD WAS COMPLETED FOR BATCH# 2213837. ALL INSPECTIONS AND CHALLENGES WERE PERFORMED PER THE APPLICABLE OPERATIONS QC SPECIFICATIONS. BASED ON THE SAMPLE RECEIVED, EMBECTA WAS ABLE TO CONFIRM THE CUSTOMER INDICATED ISSUE. A DEFINITIVE ROOT-CAUSE COULD NOT BE DETERMINED.

Additional Manufacturer Narrative · 0

DATE OF EVENT IS UNKNOWN; AWARENESS DATE HAS BEEN USED FOR THIS FIELD. A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 0

IT WAS REPORTED WHILE USING RELION INSULIN SYRINGE 3/10ML 29G X 8MM FOREIGN MATTER WAS FOUND. THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: PET OWNER REPORTED LIQUID COMING FROM SYRINGE WHEN DEPRESSING PLUNGER ROD, DURING PRIMING.

Description of Event or Problem · 0

IT WAS REPORTED WHILE USING RELION INSULIN SYRINGE 3/10ML 29G X 8MM FOREIGN MATTER WAS FOUND. THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: PET OWNER REPORTED LIQUID COMING FROM SYRINGE WHEN DEPRESSING PLUNGER ROD, DURING PRIMING.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1407495 RELION INSULIN SYRINGE 3/10ML 29G X 8MM PISTON SYRINGE FMF BD MEDICAL - DIABETES CARE 328512 2213837 00681131311786

Patients

Seq Age Sex Outcome Treatment
1 Unknown